• Title/Summary/Keyword: Time-to-digital Converter

Search Result 325, Processing Time 0.027 seconds

A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates (3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

Dynamic Reference-based Voltage Droop Control for VSC-MTDC System

  • Kim, Nam-Dae;Kim, Hak-Man;Park, Jae-Sae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2249-2255
    • /
    • 2015
  • The use of voltage source converter multi-terminal direct current (VSC-MTDC) systems is anticipated to increase from the introduction of wind farms and super grids in the near future. Effective control of the DC voltage in VSC-MTDC systems is an important research topic. This paper proposes a new dynamic reference-based voltage droop control to control the DC voltage in VSC-MTDC systems more effectively. The main merit of the dynamic reference-based voltage droop control is that it can reduce the steady-state error in conventional voltage droop control by changing references according to the system operating conditions. The performance of the proposed control was tested in a hardware-in-the-loop simulation (HILS) system based on the OPAL-RT real-time digital simulator and four digital signal processing boards.

A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY (디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구)

  • Kwon Ki Jeong;Hwang Eui-Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

Development of a High-speed Color Graphic Processor with a Real-time Image processing Capability (실시간 영상처리 기능을 갖는 고속 칼라 그래픽 프로세서의 개발)

  • Bien, Zeung-Nam;Oh, Sang-Rtok;Jang, Won;You, Bum-Jae;Park, Jong-Cheol;Ha, Kyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.443-445
    • /
    • 1990
  • In this paper, a high speed graphic processor module with a real-time processing capability is proposed, where the module is design to be compatible to the standard VME bus and consists of TMS34010 Graphic processor, TMS44C251 frame buffer, 512KB system memory and BT101 digital to analog converter. The proposed graphic module is implemented and tested in real-time via experiments with an integrated system with other VME modules.

  • PDF

A Low Cost Maximum Power Point Tracking Technique for the Solar Charger

  • Nguyen, Thanh Tuan;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.5-6
    • /
    • 2012
  • In this paper, a simplified maximum power point tracking technique for the solar charger is presented. Main advantages of the proposed charger include low cost and optimized charge time. The maximum power point tracking method is used to deliver the maximum power from PV array to the battery thereby reducing the charge time. Moreover, the proposed technique which tracks the maximum power point by adjusting output current helps reduce the quantity of required number of sensors for the charger. The experimental protype was implemented by using an 80W PV array, a buck converter and a digital signal processor to verify the feasibility of the proposed method.

  • PDF

Average Current Control of Active Power Filters Using Predictive Current Controller (예측전류제어기를 이용한 능동전력필터 시스템의 평균치 전류제어)

  • Kim, Min-Keuk;Woo, Myung-Ho;Jeong, Seung-Gi;Park, Ki-Won;Choi, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.295-299
    • /
    • 1996
  • When the current of a power converter is controlled with a digital controller, it generally shows the error due to execution time delay. The error may be considerable in such systems as active power filters wherein the current varies steeply even in steady state, as well as in transients. Therefore, it is of particular importance to compensate the time delay effect in a digitally-controlled active power filter. This paper introduces a modification of so-called predictive current control, by taking the control time delay into consideration. The results of simulation and experiment with a 10 kVA active power filter prototype show considerable improvement in current tracking capability, validating the proposed current control method.

  • PDF

Digitally Current Controlled DC-DC Switching Converters Using an Adjacent Cycle Sampling Strategy

  • Wei, Tingcun;Wang, Yulin;Li, Feng;Chen, Nan;Wang, Jia
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.227-237
    • /
    • 2016
  • A novel digital current control strategy for digitally controlled DC-DC switching converters, referred to as Adjacent Cycle Sampling (ACS), is proposed in this paper. For the ACS current control strategy, the available time interval from sampling the current to updating the duty ratio, is approximately one switching cycle. In addition, it is independent of the duty ratio. As a result, the contradiction between the processing speed of the hardware and the transient response speed can be effectively relaxed by using the ACS current control strategy. For digitally controlled buck DC-DC switching converters with trailing-edge modulation, digital current control algorithms with the ACS control strategy are derived for three different control objectives. These objectives are the valley, average, and peak inductor currents. In addition, the sub-harmonic oscillations of the above current control algorithms are analyzed and eliminated by using the digital slope compensation (DSC) method. Experimental results based on a FPGA are given, which verify the theoretical analysis results very well. It can be concluded that the ACS control has a faster transient response speed than the time delay control, and that its requirements for hardware processing speed can be reduced when compared with the deadbeat control. Therefore, it promises to be one of the key technologies for high-frequency DC-DC switching converters.

QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY (Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석)

  • Ryue, Myung-Girl;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

Flow Measurement and Control by Time-Based Method

  • Chang, Young-Chul;Kim, No-Hyu;Kim, Yong-Cheol
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.115-116
    • /
    • 2002
  • This study aimed to investigate flow measurement by using a 'bucket and stop-watch' method of flow measurement. Most flow measurement systems measure pressure or other fluid properties to infer flow rate, though time is a variable which can be easily and very accurately measured. The main principle behind the method was to fill up a reservoir until a set pressure had been reached. This reservoir would then be emptied and the cycle would repeat itself. The prototype was designed to control flow rate using the method. It made use of computer control with an analogue digital converter and fast acting solenoid valves which controlled the flow into a reservoir. Reservoirs were available with internal diameter of 1mm up to 5.5mm to cope with a range of flow rate.

  • PDF

A Study on the PWM Control of Hydraulic Equipment Using High Speed On-Off Valve (고속전자밸브를 사용한 유압장치의 PWM 제어에 관한 연구)

  • ;Wennmacher,G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.868-876
    • /
    • 1995
  • This study deals with a position control of an electro-hydraulic servo system which consist of cylinder and high speed on-off valves operated by microcomputer. The merits of PWM control of hydraulic equipment are the robustness of the high spee on-off valve, its low price and the direct control without D/A converter. In the PWM control of high speed on-off valve, the time lag and switching time existing between the input and output signals of valve are considered as demerit points. To get analytical results, the effects of these demerits have to be clarified in detail. The object of this study is to propose a mathematical model for the behavior of high speed on-off valve and to get analytical results of this system. The dynamic characteristics of this system is examined by digital computer simulation analytically and compared with experimental results to varify the proposed mathematical model.