• Title/Summary/Keyword: Time-resolved spectroscopy

Search Result 103, Processing Time 0.026 seconds

Time-resolved UV Fluorescence Spectroscopy of Aorta and its Related Chromophores, Collagen and Elastin, Using 320 nm Excitaion

  • Park, Young D.
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.3
    • /
    • pp.249-256
    • /
    • 1994
  • Fluorescence time decay of human aorta has been measured at 380, 440, 480 nm using 320 nm excitation and time-correlated single photon counting technique. Fluorescence decay was found to be nonexponential at all emission frequencies. The normal and diseased sample showed significantly different fluorescence behaviors at 380 nm while this time decay difference was decreased in the fluorescence at 440 and 480 nms. The decay data were multiexponential and were analyzed with two exponential decay constants. The fluorescence decays were compared with and analyzed in terms of collagen and elastin.

Nonlinear Optical Properties and Photoluminescence of CuCl Nanocrystals Embedded in Silica Glass

  • 이민영
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.126-129
    • /
    • 1995
  • Linear and nonlinear optical properties of CuCl nanocrystals in silica glass have been studied using low temperature absorption, degenerate four wave mixing (DFWM), and time-resolved photoluminescence spectroscopy. Assuming a spherical shape, effective radius of the CuCl quantum dots was estimated to be 2.5 nm, which is obtained from low temperature absorption data. The DFWM experiment was performed in 380-386 nm wavelength region, and the diffracted signal was measured as a function of wavelength with 1.0 nm interval. Time-resolved photoluminescence measurement was also carried out at 77 K to obtain the time response of CuCl nanocrystals. The experimental results on the large third order nonlinear optical of CuCl quantum dots are explained in terms of crystal size and oscillator strength of quantum spheres.

Ultrafast Time-Resolved Laser Spectroscopic Studies of trans-Bis(ferrocene-carboxylato)(tetraphenyl-porphyrinato)tin(IV): Intramolecular Electron-Transfer Dynamics

  • Jang, Joon-Hee;Kim, Hee-Jung;Kim, Hee-Joon;Kim, Chul-Hoon;Joo, Tai-Ha;Cho, Dae-Won;Yoon, Min-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.1967-1972
    • /
    • 2007
  • Photophysical properties of a newly-synthesized porphyrin derivative, trans-bis(ferrocene carboxylato)- (5,10,15,20-tetraphenylporphyrinato)tin(IV) [Sn(TPP)(FcCOO)2] were investigated by means of steady-state and fs-time resolved laser spectroscopic techniques, and compared with those of a standard molecule, trans-dichloro( 5,10,15,20-tetraphenyl-porphrinato)tin(IV) [Sn(TPP)Cl2]. The fluorescence spectrum of Sn(TPP)- (FcCOO)2 was observed to exhibit dual emission bands originating from the S2-state and the S1-state, which was greatly quenched as compared to those of Sn(TPP)Cl2. The fs-time resolved fluorescence and transient absorption spectroscopic measurements revealed that the fluorescence quenching is due to formation of the long-lived charge transfer state by intramolecular electron transfer from ferrocene to the S2-excited SnTPP in addition to the enhanced non-radiative deactivation processes.

Direct Time-domain Phase Correction of Dual-comb Interferograms for Comb-resolved Spectroscopy

  • Lee, Joohyung
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.289-297
    • /
    • 2021
  • We describe a comb-mode resolving spectroscopic technique by direct time-domain phase correction of unstable interferograms obtained from loosely locked two femtosecond lasers. A low-cost continuous wave laser and conventional repetition rate stabilization method were exploited for locking carrier and envelope phase of interferograms, respectively. We intentionally set the servo control at low bandwidth, resulting in severe interferograms' fluctuation to demonstrate the capability of the proposed correction method. The envelope phase of each interferogram was estimated by a quadratic fit of carrier peaks to correct timing fluctuation of interferograms in the time domain. After envelope phase correction on individual interferograms, we successfully demonstrated 1 Hz linewidth of RF comb-mode over 200 GHz optical spectral-bandwidth with 10-times signal-to-noise ratio (SNR) enhancement compared to the spectrum without correction. Besides, the group delay difference between two femtosecond pulses is successfully estimated through a linear slope of phase information.

Partial Least Squares-discriminant Analysis for the Prediction of Hemodynamic Changes Using Near Infrared Spectroscopy

  • Seo, Youngwook;Lee, Seungduk;Koh, Dalkwon;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.57-62
    • /
    • 2012
  • Using continuous wave near-infrared spectroscopy, we measured time-resolved concentration changes of oxy-hemoglobin and deoxy-hemoglobin from the primary motor cortex following finger tapping tasks. These data were processed using partial least squares-discriminant analysis (PLS-DA) to develop a prediction model for a brain-computer interface. The tasks were composed of a series of finger tapping for 15 sec and relaxation for 45 sec. The location of the motor cortex was confirmed by the anti-phasic behavior of the oxy- and deoxy-hemoglobin changes. The results were compared with those obtained using the hidden Markov model (HMM) which has been known to produce the best prediction model. Our data imply that PLS-DA makes better judgments in determining the onset of the events than HMM.

Direct Aerosol Analysis by Time Resolved Laser Plasma Spectroscopy - Improvement by Single Shot Measurements

  • Schechter, Israel
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.779-786
    • /
    • 1995
  • Environmental and industrial aerosols can be analyzed on-line by laser plasma spectroscopy. The main problem in direct (no preparation or presorting) aerosol analysis is the extensive spectral fluctuations. A method to partially solve this problem is proposed. It is based on single shot measurements and application of a special rejection algorithm. The major factors that influence the spectral variations are discussed, in relation to the correction possibility by a rejection program. The method works well when average intensity of the single spectra is relatively high, as compared to detector's saturation limit. If intensities are too low, the accumulation of readout noise is critical, and no improvement is expected.

  • PDF

Observation of Methyl Radical Recombination Following Photodissociation of CH3I at 266 nm by Time-Resolved Photothermal Spectroscopy

  • Suh, Myung-Koo;Sung, Woo-Kyung;Li, Guo-Sheng;Heo, Seong-Ung;Hwang, Hyun-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.318-324
    • /
    • 2003
  • A time-resolved probe beam deflection (PBD) technique was employed to study the energy relaxation dynamics of photofragments produced by photodissociation of $CH_3I$ at 266 nm. Under 500 torr argon environment, experimental PBD transients revealed two energy relaxation processes; a fast relaxation process occurring within an acoustic transit time (less than 0.2 ㎲ in this study) and a slow relaxation process with the relaxation time in several tens of ㎲. The fast energy relaxation of which signal intensity depended linearly on the excitation laser power was assigned to translational-to-translational energy transfer from the photofragments to the medium. As for the slow process, the signal intensity depended on square of the excitation laser power, and the relaxation time decreased as the photofragment concentration increased. Based on experimental findings and reaction rate constants reported previously, the slow process was assigned to methyl radical recombination reaction. In order to determine the rate constant for methyl radical recombination reaction, a theoretical equation of the PBD transient for a radical recombination reaction was derived and used to fit the experimental results. By comparing the experimental PBD curves with the calculated ones, the rate constant for methyl recombination is determined to be $3.3({\pm}1.0)\;{\times}\;10^6\;s^{-1}torr^{-1}$ at 295 ± 2 K in 500 torr Ar.

Gapped Nearly Free-Standing Graphene on an SiC(0001) Substrate Induced by Manganese Atoms

  • Hwang, Jinwoong;Lee, Ji-Eun;Kang, Minhee;Park, Byeong-Gyu;Denlinger, Jonathan;Mo, Sung-Kwan;Hwang, Choongyu
    • Applied Science and Convergence Technology
    • /
    • v.27 no.5
    • /
    • pp.90-94
    • /
    • 2018
  • The electron band structure of manganese-adsorbed graphene on an SiC(0001) substrate has been studied using angle-resolved photoemission spectroscopy. Upon introducing manganese atoms, the conduction band of graphene, that is observed in pristine graphene indicating intrinsic electron-doping by the substrate, completely disappears and the valence band maximum is observed at 0.4 eV below Fermi energy. At the same time, the slope of the valence band decreases by the presence of manganese atoms, approaching the electron band structure calculated using the local density approximation method. The former provides experimental evidence of the formation of nearly free-standing graphene on an SiC substrate, concomitant with a metal-to-insulator transition. The latter suggests that its electronic correlations are efficiently screened, suggesting that the dielectric property of the substrate is modified by manganese atoms and indicating that electronic correlations in grpahene can also be tuned by foreign atoms. These results pave the way for promising device application using graphene that is semiconducting and charge neutral.

Spectroscopy of Visible Light Emitted from Plasma Occurred by Pulse Discharge (펄스형 방전플라스마에서 발생하는 가시광선의 분광특성 연구)

  • Choi, Woon Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 1998
  • We investigated visible light radiated from Plasma focus device by time-resolved analyzed method and time-integrated analyzed method. Plasma focus consisted of two coaxial electrodes is a device that translated from electric energy of maximum 40 kV/20 kJ in capacitor banks into visible light by electric discharge. Spectral analysis is using Monochromator(f =0.5m). Time-resolved spectrum is analyzed with a oscilloscope the light pulse of constant wavelength and time-integrated spectrum does with densitometer the film which developed a constant range of wavelength. The optimum condition of visible emission was that the discharging voltage was 17kV and the gas pressure 0.5 torr Ar.

  • PDF

Magnetic Resonance Findings in Two Episodes of Repeated Cerebral Fat Embolisms in a Patient with Autologous Fat Injection into the Face

  • Lee, Kyung-Mi;Kim, Eui-Jong;Jahng, Geon-Ho;Chang, Dae-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.5
    • /
    • pp.312-315
    • /
    • 2012
  • We report magnetic resonance image (MRI) and magnetic resonance spectroscopy (MRS) findings in a patient of cerebral fat embolism (CFE) occurred in a 26-year-old woman after an autologous fat injection into the face. After initial neurologic symptom onset, MRI and MRS data were obtained two times to investigate repeated CFE. We obtained the MRS data in the two different time intervals and two different echo times to compare the lesions with normal brain parenchyma. The results of MRS data showed that a decrease in N-acetyl-aspartate, an increase in lactate and a very high early peak of free lipids between 0.9 and 1.4 ppm were obtained at the acute infarcted lesion as compared with normal brain parenchyma. In addition, these findings were more clearly detected on short echo time spectrum rather than long spectrum. A close relationship between the clinical manifestations and MRI and MRS findings of the brain can helpful to distinguish CFE with other conditions and to evaluate the cause materials of infarctions rather than conventional MRI or diffusion-weighted imaging.