• Title/Summary/Keyword: Time-resolved analysis

Search Result 182, Processing Time 0.028 seconds

Surgical Resection of Neurogenic Heterotopic Ossification around Hip Joint in Stroke Patients: A Safety and Outcome Report

  • Jae-Young Beom;WengKong Low;Kyung-Soon Park;Taek-Rim Yoon;Chan Young Lee;Hyeongmin Song
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.268-276
    • /
    • 2023
  • Purpose: Resection remains the most reliable treatment for established heterotopic ossification, despite questions regarding its effectiveness due to the potential for complications. This study evaluated the clinical outcomes and complications of neurogenic heterotopic ossification (NHO) resection in stroke patients' ankylosed hips. Materials and Methods: We retrospectively analyzed nine hip NHO resections performed on seven patients from 2010 to 2018. The pre- and postoperative range of motion of the operated hip were compared. Analysis of postoperative complications, including infection, recurrence, iatrogenic fracture, and neurovascular injury was performed. Results: The mean operative time was 132.78±21.08 minutes, with a mean hemoglobin drop of 3.06±0.82 g/dL within the first postoperative week. The mean duration of postoperative follow-up was 52.08±28.72 months for all patients. Postoperative range of motion showed improvement from preoperative. Flexion and external rotation (mean, 58.89±30.60° and 16.67±18.03°, respectively) showed the greatest gain of motion of the operated hip joint. Postoperative infections resolved in two cases through surgical debridement, and one case required conversion to total hip arthroplasty due to instability. There were no recurrences, iatrogenic fractures, or neurovascular injuries. Conclusion: Resection is a beneficial intervention for restoring the functional range of motion of the hip in order to improve the quality of life for patients with NHO and neurological disorders. We recommend performance of a minimal resection to achieve a targeted functional arc of motion in order to minimize the risk of postoperative complications.

Trends in Regional Disparity in Cardiovascular Mortality in Korea, 1983-2019

  • Eunji Kim;Jongmin Baek;Min Kim;Hokyou Lee;Jang-Whan Bae;Hyeon Chang Kim
    • Korean Circulation Journal
    • /
    • v.52 no.11
    • /
    • pp.829-843
    • /
    • 2022
  • Background and Objectives: Despite remarkable reduction in cardiovascular disease (CVD) mortality, the burden has remained the leading cause of death. Since little research has focused on regional disparity in CVD mortality, this study aims to investigate its spatiotemporal trends in Korea from 1983 to 2019. Methods: Using the causes of death statistics in Korea, we analyzed the geographic variation in deaths from CVDs from 1983 to 2019. The sex and age-standardized mortality rate was calculated according to the 17 administrative regions. The analyses include all diseases of the circulatory system (International Classification of Diseases-10 codes, I00-I99), along with the following 6 subcategories which were not mutually exclusive: total heart disease (I00-I13 and I20-I51), hypertensive heart disease (I10-I13), ischemic heart disease (I20-I25), myocardial infarction (I21-I23), heart failure (I50), and cerebrovascular disease (I60-I69). Results: Overall, heart failure death rate increased across all regions, and other CVD death rates showed a decreasing trend. Regional disparity in mortality was substantial in the early 1980s but converged over time. In all types of cardiovascular mortality, Busan, Ulsan and Gyeongnam remained the highest, although they showed a downward trend like other regions. Jeju continued to have a relatively low CVD mortality rate. Conclusions: The regional disparity substantially decreased compared to the 1980s. However, the relatively high burden of CVD mortality in the southeastern region has not been fully resolved.

Natural course of chronic subdural hematoma following surgical clipping of unruptured intracranial aneurysm by pterional approach

  • Su-Bin Kweon;Suchel Kim;Min-Yong Kwon;Chang-Hyun Kim;Sae Min Kwon;Yong San Ko;Chang-Young Lee
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.390-402
    • /
    • 2023
  • Objective: Chronic subdural hematoma (CSDH) is a neurological complication following clipping surgery. However, the natural course and ideal approach for the treatment of clipping-related-CSDH (CR-CSDH) have not been clearly established. We aimed to investigate the course of CR-CSDH using chronological radiological findings. Methods: We performed a retrospective analysis of 28 (3.8%) patients who developed CSDH among 736 patients who underwent surgical clipping using pterional approach for unruptured aneurysms at our institution between December 2010 and December 2018. Patients underwent follow-up CT scan 6-8 weeks after clipping surgery and decision to pursue surgical intervention rests upon the patient's symptom based on the Markwalder's grading scale (MGS) and numeric rating scale (NRS). Results: Of the 28 patients, 3 patients (10.7%) underwent surgery, while 25 (89.2%) showed spontaneous resolution of CR-CSDH. Eighteen patients (64.2%) had mild headache with MGS of 0-1. The mean maximum hematoma volume was 41.9±30.9 ml (5.8-135 ml), and 26 patients (92.8%) had homogeneous hematoma. The mean time to hematoma resolution was 126.7±52.9 days (46-228 days). Comparing group of CR-CSDH volume ≥43 ml or a midline shift ≥5 mm, the difference in presence of linear low-density area (p=0.002) and age (p=0.026) between the conservative and operative groups were found to be statistically significant. Conclusions: Most CR-CSDH cases spontaneously resolved within 4 months. Therefore, we suggest that close observation should be performed if patient's symptoms are mild and special radiologic findings are present, despite its relatively large volume and midline shifting.

Spectroscopic Studies on U(VI) Complex with 2,6-Dihydroxybenzoic acid as a Model Ligand of Humic Acid (분광학을 이용한 흄산의 모델 리간드인 2,6-Dihydroxybenzoic acid와 우라늄(VI)의 착물형성 반응에 관한 연구)

  • Cha, Wan-Sik;Cho, Hye-Ryun;Jung, Euo-Chang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.207-217
    • /
    • 2011
  • In this study the complex formation reactions between uranium(VI) and 2,6-dihydroxybenzoate (DHB) as a model ligand of humic acid were investigated by using UV-Vis spectrophotometry and time-resolved laser-induced fluorescence spectroscopy (TRLFS). The analysis of the spectrophotometric data, i.e., absorbance changes at the characteristic charge-transfer bands of the U(VI)-DHB complex, indicates that both 1:1 and 1:2 (U(VI):DHB) complexes occur as a result of dual equilibria and their distribution varies in a pH-dependent manner. The stepwise stability constants determined (log $K_1$ and log $K_2$) are $12.4{\pm}0.1$ and $11.4{\pm}0.1$. Further, the TRLFS study shows that DHB plays a role as a fluorescence quencher of U(VI) species. The presence of both a dynamic and static quenching process was identified for all U(VI) species examined, i.e., ${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$, and $(UO_2)_3{(OH)_5}^+$. The fluorescence intensity and lifetimes of each species were measured from the time-resolved spectra at various ligand concentrations, and then analyzed based on Stern-Volmer equations. The static quenching constants (log $K_s$) obtained are $4.2{\pm}0.1$, $4.3{\pm}0.1$, and $4.34{\pm}0.08$ for ${UO_2}^{2+}$, $(UO_2)_2{(OH)_2}^{2+}$, and $(UO_2)_3{(OH)_5}^+$, respectively. The results of Stern-Volmer analysis suggest that both mono- and bi-dentate U(VI)-DHB complexes serve as groundstate complexes inducing static quenching.

Analysis of Conformability for Cadastral Control Network Using GPS Satellite Surveying (GPS에 의한 지적삼각망의 정합성 분석)

  • Kang, Joon-Mook;Yoon, Hee-Cheon;Kim, Hong-Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.2 no.1 s.3
    • /
    • pp.121-129
    • /
    • 1994
  • A number of existing cadastral control stations have been destroyed and shifted by a long lapse of time and careless management. Also, results of them are partly poor owing to dependence on conventional survey method. Because of these, it is very difficult in use of results. Hereupon, correction of cadastral results is necessary in level of government. But it is very consumable to check and adjust results with existing equipments and related techniques only. It is required that this problem can be resolved efficiently. This study analyzed the conformability for cadastral control network to GPS, GPS, which determine precise 3-D coordinates on a short time, to positioning of cadastral stations. We chose DaeJon city for the test area of this study and analyzed the precision of network composed of sixteen cadastral control stations. We made comparision the old result and the new outcome which obtained from coordinate transformation method and horizontal network adjustment method. As a result of this, we detected the blunder of cadastral stations. Furthermore, we suggested effective network type according to precision analysis of GPS observation network. Therefore, there is no doubt that GPS surveying can be applied to checking and adjustment of cadastral control network. Hereafter, it is expected that the practical use of GPS is advanced in a field of cadastration.

  • PDF

Traffic Impacts of Transit-oriented Urban Regeneration (TOD형 도시재생사업의 교통영향 분석)

  • Hwang, Kee Yeon;Cho, Yong Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4D
    • /
    • pp.469-476
    • /
    • 2008
  • Recently, TOD gains popularity as a traffic solution measure of high density urban regeneration projects. The purpose of this study is to investigate traffic impacts of high density TOD projects, and to identify the issues to be resolved. For a case study, it chooses Gangnamgucheong station in Gangnam area served by two subway lines, and designates 400m radius from the station as a site for high-density development. The MOEs chosen for this study is traffic volume, time, distance, speed, and mode share. The SECOM model is adopted for traffic simulation. The analysis results show that high-density TOD is an effective tool for traffic improvement even with only one station area being implemented. It is found that the traffic volume increases near the station in nature where high-density development occurs, but it declines overall in the rest of Gangam area. The total travel time and distance of passenger vehicles decline, meaning that the traffic condition becomes better than before. With regulation on parking supply, the improvement becomes more vivid. In terms of the changes of traffic speed, both alternatives show 4.1% increase in speed, but the difference between alternatives is not quite noticeable because of the induced vehicle demand driven to the streets with improved traffic condition. The mode share changes occur for the benefit of subway ridership, because the study station is equipped with two subway line services. When mixed with parking supply restriction, the impact becomes clearer.

Study of the Efficiency Droop Phenomena in GaN based LEDs with Different Substrate

  • Yoo, Yang-Seok;Li, Song-Mei;Kim, Je-Hyung;Gong, Su-Hyun;Na, Jong-Ho;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.172-173
    • /
    • 2012
  • Currently GaN based LED is known to show high internal or external efficiency at low current range. However, this LED operation occurs at high current range and in this range, a significant performance degradation known as 'efficiency droop' occurs. Auger process, carrier leakage process, field effect due to lattice mismatch and thermal effects have been discussed as the causes of loss of efficiency, and these phenomena are major hindrance in LED performance. In order to investigate the main effects of efficiency loss and overcome such effects, it is essential to obtain relative proportion of measurements of internal quantum efficiency (IQE) and various radiative and nonradiative recombination processes. Also, it is very important to obtain radiative and non-radiative recombination times in LEDs. In this research, we measured the IQE of InGaN/GaN multiple quantum wells (MQWs) LEDs with PSS and Planar substrate using modified ABC equation, and investigated the physical mechanism behind by analyzing the emission energy, full-width half maximum (FWHM) of the emission spectra, and carrier recombination dynamic by time-resolved electroluminescence (TREL) measurement using pulse current generator. The LED layer structures were grown on a c-plane sapphire substrate and the active region consists of five 30 ${\AA}$ thick In0.15Ga0.85N QWs. The dimension of the fabricated LED chip was $800um{\times}300um$. Fig. 1. is shown external quantum efficiency (EQE) of both samples. Peak efficiency of LED with PSS is 92% and peak efficiency of LED with planar substrate is 82%. We also confirm that droop of PSS sample is slightly larger than planar substrate sample. Fig. 2 is shown that analysis of relation between IQE and decay time with increasing current using TREL method.

  • PDF

A Study of Correcting Technology based POI for Pedestrian Location-information Detecting in Traffic Connective Transferring System (교통 연계 환승 시스템의 보행자 위치정보 수집을 위한 POI 기반 위치 보정 기술 연구)

  • Jung, Jong-In;Lee, Sang-Sun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.2
    • /
    • pp.84-93
    • /
    • 2011
  • In order to provide the real time and proper information to the pedestrian who is using the transport connection and transfer center through data collecting and processing process, the design of the test-bed (Gimpo airport)'s communication construction and the technology of the pedestrian location tracking has been researched. The design of the communication construction should make sure that it can provide believable data to the user of the transfer center. At the same time, the location tracking should also be considered, so that the require of the communication efficiency and the location tracking efficiency can be met together. In order to make the efficient location tracking technology, the problems related to the commercial technology based real time location identification will be resolved and the new approach method was proposed and be applied and analysed to the test-bed. The wireless access points can be located in the most real-world situation which has added the characteristics of the real building to the electronic map, and through the analysis of theirs location, they can be set as the mainly necessary points for the communication construction design and the location tracking and the method to locate that points has been proposed. How to set, how to apply it to the test-bed and the examination result will be introduced in this paper.

Analysis of Treatment and Delay Times by Disease Site and Delivery Technique at Samsung Medical Center - Proton Therapy Center

  • Jo, Kwanghyun;Ahn, Sung Hwan;Chung, Kwangzoo;Cho, Sungkoo;Shin, Eunhyuk;Hong, Chae-Seon;Park, Seyjoon;Kim, Dae-Hyun;Lee, Boram;Lee, Woo-Jin;Seo, Se-Kwang;Jang, Jun-Young;Choi, Doo Ho;Lim, Do Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.258-266
    • /
    • 2016
  • We have treated various disease sites using wobbling and scanning proton therapy techniques since December 2015 at the Samsung Medical Center. In this study, we analyze the treatment time for each disease site in 65 wobbling and 50 scanning patient treatments. Treatment times are longest for liver and lung patients using the respiratory gating technique in the wobbling treatment and for cranio-spinal irradiation in pediatric patients with anesthesia in the scanning treatment. Moreover, we analyze the number of incidents causing treatment delays and the corresponding treatment delay time. The X-ray panel was the main reason for delays in the wobbling treatment; this decreased continually from January to June 2016, related closely to the proficiency of the human operators involved. The main reason for delays in the scanning treatment was interlocks during scanning pattern delivery; this was resolved by proton machine engineers. Through this work, we hope to provide other institutes with useful insight for initial operation of their proton therapy machines.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF