• Title/Summary/Keyword: Time of flight measurement

Search Result 173, Processing Time 0.032 seconds

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

Influence of Diverse Atmospheric Conditions on Optical Properties of a Pulse Laser in a Time-of-Flight Laser Range Finder

  • Shim, Young Bo;Kwon, Oh-Jang;Choi, Hyun-Yong;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • We investigate the propagation characteristics of a pulse laser in a time-of-flight laser range finder (TOF-LRF) system with variations in atmospheric conditions, such as temperature, pressure, relative humidity, and the concentration of $CO_2$. The measurement error of distance related with the group velocity change in the TOF-LRF system is analyzed by considering the refractive index of the standard atmosphere with variations in atmospheric conditions. The dependence of the pulse width broadening induced by chromatic dispersion of the standard atmosphere on the operating wavelength and the initial pulse width of the light sources is discussed. The transmission of air with variations in the relative humidity or the concentration of $CO_2$ is analyzed by using different values of absorption coefficients depending on the operation wavelength of the light source in the TOF-LRF system.

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.

An Efficient Algorithm for 3-D Range Measurement using Disparity of Stereoscopic Camera (스테레오 카메라의 양안 시차를 이용한 거리 계측의 고속 연산 알고리즘)

  • 김재한
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.6
    • /
    • pp.1163-1168
    • /
    • 2001
  • The ranging systems measure range data in three-dimensional coordinate from target surface. These non-contact remote ranging systems is widely used in various automation applications, including military equipment, construction field, navigation, inspection, assembly, and robot vision. The active ranging systems using time of flight technique or light pattern illumination technique are complex and expensive, the passive systems based on stereo or focusing principle are time-consuming. The proposed algorithm, that is based on cross correlation of projection profile of vertical edge, provides advantages of fast and simple operation in the range acquisition. The results of experiment show the effectiveness of the proposed algorithm.

  • PDF

Ultrasonic Distance Measurement Method by Using the Envelope Model of Received Signal Based on System Dynamic Model of Ultrasonic Transducers

  • Choe, Jin-Hee;Lee, Kook-Sun;Choy, Ick;Cho, Whang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.981-988
    • /
    • 2018
  • In order to acquire an accurate TOF, this paper proposes a method that produces TOF by using a mathematical model for the envelope of the received signal obtained from a system dynamic model of ultrasonic transducer. The proposed method estimates the arrival time of the received signal retrospectively by comparing its wave form obtained after triggering point with its mathematical envelope model. Experimental result shows that the error due to variation of triggering point can be dramatically decreased by implementing the proposed method.

Attitude Determination GPS/INS Integrated Navigation System with FDI Algorithm for a UAV

  • Oh Sang Heon;Hwang Dong-Hwan;Park Chansik;Lee Sang Jeong;Kim Se Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1529-1543
    • /
    • 2005
  • Recently an unmanned aerial vehicle (UAV) has been widely used for military and civil applications. The role of a navigation system in the UAV is to provide navigation data to the flight control computer (FCC) for guidance and control. Since performance of the FCC is highly reliant on the navigation data, a fault in the navigation system may lead to a disastrous failure of the whole UAV. Therefore, the navigation system should possess a fault detection and isolation (FDI) algorithm. This paper proposes an attitude determination GPS/INS integrated navigation system with an FDI algorithm for a UAV. Hardware for the proposed navigation system has been developed. The developed hardware comprises a commercial inertial measurement unit (IMU) and the integrated navigation package (INP) which includes an attitude determination GPS (ADGPS) receiver and a navigation computer unit (NCU). The navigation algorithm was implemented in a real-time operating system with a multi-tasking structure. To evaluate performance of the proposed navigation system, a flight test has been performed using a small aircraft. The test results show that the proposed navigation system can give accurate navigation results even in a high dynamic environment.

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Comparison of Vertical Ground Reaction Forces during Jump between Elderly and Young Adults using Nintendo Wii Balance Board

  • Lim, Jiyoung;Yu, Deokhyeon;Kim, Chaeyoung;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.2
    • /
    • pp.161-166
    • /
    • 2021
  • Objective: The purpose of this study was to quantitatively evaluate the Wii Balance Board (WBB)-based jump performance for the elderly and to confirm the difference in jump performance according to age. Design: Cross-sectional study. Methods: 40 young adults (aged 22.5±2.2 years) and 33 elderly (aged 75.1±5.2 years) without orthopedics disease participated in this study. Standing on the WBB then, with the signal "start," jump vertically to the maximum height at which you can jump, land on the force plate after jump and keep it standing on both feet. All subjects were required to practice the jump sufficiently before starting the measurement, each measuring three times, and the mean values were used. A one-minute break was provided between each trial. Evaluators waited within 1meter for every test to prepare for fall. Results: The vertical ground reaction force of elderly and young adults when jumping using WBB showed a significant difference (p<0.05) and demonstrated discriminant validity. Between two groups, there were significant differences in overall jump time (p<0.05), maximum value (p<0.05), minimum value (p<0.05), center of pressure (COP) pathlength (p<0.05), and flight time p<0.05). Conclusions: This study found that performing the vertical jump, the elderly showed longer jump time, lower vertical ground reaction force, COP pathlength and shorter flight phase than healthy young adults using WBB and demonstrated that as a measurement tool, WBB discriminated vertical jump performance between elderly and young adults.

Satellite data validation system using RC helicopter

  • Honda, Yoshiaki;Kajiwara, Koji
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.746-749
    • /
    • 2002
  • This paper is introducing a radio control helicopter as a new platform of ground truth measurement. This helicopter is normally used for spraying an agricultural chemical. It can do pinpoint hovering and programing flight using DGPS etc., A spectrometer with dual port can measure ground surface and white reference plate at the same time. And it can also take digital images by digital camera. It is needed to collect ground reflectance information as satellite sensor footprint size for satellite data validation. Generally it is possible to get such ground reflectance by an airplane measurement. But it is high cost and not so easy to make a measurement by airplane. Developed validation system can provide such ground reflectance in low cost and easy.

  • PDF