• Title/Summary/Keyword: Time difference of arrival

Search Result 298, Processing Time 0.023 seconds

A study on Medical servicer satisfaction of Emergency Department patient (응급실 내원자의 의료서비스 만족에 관한 연구)

  • Kwon, Seon Suk;Yoo, In Soo;Jung, Ha Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.1 no.1
    • /
    • pp.42-53
    • /
    • 1997
  • To offer basic data about the influential factors on patient's Satisfaction level for emergency medical services the authors were performed this study in 60 patients visited to emergency room of third stage general hospital in Taejeon city. Data were collected through interview with patients by using a 15 items' questionaire according to care subscale, teaching subscale of Likert's five stage quantitative scale and the tools developed by Barbara Davis. The data were analyzed by using the SPSS/PC computerized program for mean, standard deviation, percentage, ANOVA, t-test, and pearson correlation. The results are as followings ; 1. Satisfaction of emergency medical service were showed in care area, but not showed in teaching and total area 2. Satisfaction of sociodemographic characteristics were a statistically significant difference only marriage, that were the higher in marriaged than single(P<.0.05). 3. In the emergency situation characteristics the satisfaction accordings to the visit cause were lower in accident than disease group, the reason of hospital selection were in order trust, introduction group, distance, traffic, kinds, and score of satisfaction were showed each of 43.47, 51.27(P<.001), the transportation vehicle was the 119, hospital ambulance group. but were not a satistically significant difference. 4. The negative correlation was observed between satisfaction and the length of stay at ER and the longer length of stay at ER was showed the lower satisfaction. But the positive correlation was observed between satisfacton and the arrival time, patients who arrived ER from 6:00P.M. to midnight were more satisfied than patients who arrived other time. 5. The length of stay at ER was significantly different according to the reason of hospital selection, the reason of ER selection, the visitant cause and hopital decisioner. Especially the length of stay was much longer in accident group and unconscious group.

  • PDF

Time Synchronization Technique for GNSS Jamming Monitoring Network System (GNSS 재밍 신호 모니터링 네트워크 시스템을 위한 독립된 GNSS 수신기 간 시각 동기화 기법)

  • Jin, Gwon gyu;Song, Young jin;Won, Jong hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.3
    • /
    • pp.74-85
    • /
    • 2021
  • Global Navigation Satellite System (GNSS) receivers are intrinsically vulnerable to radio frequency jamming signals due to the fundamental property of radio navigation systems. A GNSS jamming monitoring system that is capable of jamming detection, classification and localization is essential for infrastructure for autonomous driving systems. For these 3 functionalities, a GNSS jamming monitoring network consisting of a multiple of low-cost GNSS receivers distributed in a certain area is needed, and the precise time synchronizaion between multiple independent GNSS receivers in the network is an essential element. This paper presents a precise time synchronization method based on the direct use of Time Difference of Arrival (TDOA) technique in signal domain. A block interpolation method is additionally incorporated into the method in order to maintain the precision of time synchronization even with the relatively low sampling rate of the received signals for computational efficiency. The feasibility of the proposed approach is verified in the numerical simualtions.

Gauss-Newton Based Estimation for Moving Emitter Location Using TDOA/FDOA Measurements and Its Analysis (TDOA/FDOA 정보를 이용한 Gauss-Newton 기법 기반의 이동 신호원 위치 및 속도 추정 방법과 성능 분석)

  • Kim, Yong-Hee;Kim, Dong-Gyu;Han, Jin-Woo;Song, Kyu-Ha;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.62-71
    • /
    • 2013
  • The passive emitter location method using TDOA and FDOA measurements has higher accuracy comparing to the single TDOA or FDOA based method. Moreover, it is able to estimate the velocity vector of a moving platform. Recently, several non-iterative methods were suggested using the nuisance parameter but the common reference sensor is needed for each pair of sensors. They show also relatively low performance in the case of a long range between the sensor groups and the emitter. To solve this, we derive the estimation method of the position and velocity of a moving platform based on the Gauss-Newton method. In addition, to analyze the estimation performance of the position and velocity, respectively, we decompose the CRLB matrix into each subspace. Simulation results show the estimation performance of the derived method and the CEP planes according to the given geometry of the sensors.

Effects of Family Presence Intervention on Anxiety, Delirium, Pain and Length of Time in Recovery Room of Post-operative Elderly Patients in Post-anesthesia Care Units (회복실 보호자 상주가 전신마취 노인수술환자의 수술직후 상태불안, 각성섬망, 통증 및 회복실 체류시간에 미치는 영향)

  • Kim, Kyunghee;Lee, Sookhee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.2
    • /
    • pp.149-157
    • /
    • 2015
  • Purpose: The objectives of this study were to assess the influence of family presence in the PACU (Post Anesthesia Care Unit) on anxiety, emergency delirium, pain and length of stay in the recovery room for elderly patients undergoing surgery for which general anesthesia has been used. Methods: The study was a nonequivalent control group pre-post test design. Eighty elderly patients over 65 years who underwent surgery under general anesthesia were recruited. Forty were assigned to the experiment group, patients together with a family member and 40 to the control group, with no family member present. Patients' anxiety, emergency delirium, pain and length of time in the recovery room were evaluated at 10 minute and 30 minute after arrival in the PACU. Results: Patients with family members in the PACU showed significantly decreased levels of anxiety at 10 and 30 minutes and significantly lower levels of emergency delirium and pain at 30 minutes. However there was no difference between the 2 groups for length of time in the recovery room. Conclusion: The results of this study indicate that being with family members in the PACU after surgery under general anesthesia is effective for reducing elderly patients' anxiety, delirium and pain during time in the recovery room.

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

Partial Discharge Location Method using Group Velocity Difference of Modes in a Electromagnetic Partial Discharge Signal in Gas Insulated Bus (가스절연모선(GIB)에서 전자파 방전신호의 모드별 군속도 차이를 이용한 방전위치 산정기법)

  • Goo, Sun-Geun;Ju, Hyoung-Jun;Park, Ki-Jun;Han, Ki-Seon;Yoon, Jin-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2184-2188
    • /
    • 2007
  • We developed a novel method of partial discharge(PD) location based on the fact that the waveform of PD signal propagate along the GIB (Gas Insulated Bus) is composed of several modes of electromagnetic wave with different group velocities and cut-off frequencies. From the PD waveform, measured at a broadband PD sensor attached on the GIB, we could derive arrival time and frequency components of different modes using the short term Fourier transform or etc. After the group velocities of different modes are calculated, the location of the PD source could be estimated. To show the effectiveness of this new locating method in a real on site application, we used this method to locate the position of a PD source at a 76 m long 345 kV GIB substation. The estimated location of the PD source using the method proposed above was in good agreement with the actual location found from the inspection result of internal component in the GIB with 2.4% of the estimation error.

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

Frequency translation approach for transmission beamforming in FDD wireless communication systems with basestation arrays (기지국 안테나 배열을 이용한 FDD 방식의 무선통신 시스템에서 송신 빔 형성을 위한 주파수 변환 방식)

  • ;Shawn P.Stapleton
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.5
    • /
    • pp.1-14
    • /
    • 1997
  • We consider transmission beamforming techniques for frequency-division-duplex (FDD) wireless communication systems using adaptive arrays to improve the signal quality of the array transmission link. We develop a simple effective transmission beamforming technique based on an approximated frequency tranlsation (AFT) to derive the tranmsiion beamforming weights from the uplink channel vector. This technique exploits the invariance of the short-time averaged fast fading statistics to small frequency translations. A simple approximate relationship that relates the transmission channel vector to the reception channel vector is derived. We have developed its practical alternative in which the frequency translation of the channel vector is performed at the principal angle of arrival (AOA) of the u;link synthestic angular spectrum instead of the mean AOA. To analyze the performance of the proposed methods, we consider the power loss incurred by applying the estimated channel vector instead of the true downlink channel vector. The performance is analyzed as a function of the mean AOA, the angular spread, the number of elements, frequncy difference between the uplink and the downlink, and the angle distribution. Their performance is also compared with that of the direct weight reuse method and the AOA based methods.

  • PDF

Three-Dimensional Location Tracking System for Automatic Landing of an Unmanned Helicopter (무인 헬기 자동 착륙을 위한 3차원 위치 추적 시스템)

  • Choo, Young-Yeol;Kang, Seong-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.608-614
    • /
    • 2008
  • This paper describes a location tracking system to guide landing process of an Unmanned Helicopter(UMH) exploiting MIT Cricket nodes. For automatic landing of a UMH, a precise positioning system is indispensable. However, GPS(Global Positioning System) is inadequate for tracking the three dimensional position of a UMH because of large positioning errors. The Cricket systems use Time-Difference-of-Arrival(TDoA) method with ultrasonic and RF(Radio Frequency) signals to measure distances. They operate in passive mode in that a listener attached to a moving device receives distance signals from several beacons located at fixed points on ground. Inevitably, this passive type of implementation causes large disturbances in measuring distances between beacons and the listener due to wind blow from propeller and turbulence of UMH body. To cope with this problem, we proposed active type of implementation for positioning a UMH. In this implementation, a beacon is set up at UMH body and four listeners are located at ground area at least where the UMH will land. A pair of Ultrasonic and RF signals from the beacon arrives at several listeners to calculate the position of the UMH. The distance signals among listeners are synchronized with a counter value appended to each distance signals from the beacon.

Fire Resistance Characteristics of Firewall Structure Associated with Impact Damage Induced by Explosion

  • Hye Rim Cho;Jeong Hwa Yoo;Jung Kwan Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.99-110
    • /
    • 2023
  • When a fire accident accompanied by an explosion occurs, the surrounding firewalls are affected by impact and thermal loads. Damaged firewalls due to accidental loads may not fully perform their essential function. Therefore, this paper proposes an advanced methodology for evaluating the fire resistance performance of firewalls damaged by explosions. The fragments were assumed to be scattered, and fire occurred as a vehicle exploded in a large compartment of a roll-on/roll-off (RO-RO) vessel. The impact velocity of the fragments was calculated based on the TNT equivalent mass corresponding to the explosion pressure. Damage and thermal-structural response analyses of the firewall were performed using Ansys LS-DYNA code. The fire resistance reduction was analyzed in terms of the temperature difference between fire-exposed and unexposed surfaces, temperature increase rate, and reference temperature arrival time. The degree of damage and the fire resistance performance of the firewalls varied significantly depending on impact loads. When naval ships and RO-RO vessels that carry various explosive substances are designed, it is reasonable to predict that the fire resistance performance will be degraded according to the explosion characteristics of the cargo.