• Title/Summary/Keyword: Time Determination

Search Result 2,982, Processing Time 0.036 seconds

Performance Analysis of the KOMPSAT-1 Orbit Determination Using GPS Navigation Solutions (GPS 항행해를 이용한 아리랑 1호의 궤도결정 성능분석 연구)

  • Kim, Hae-Dong;Choi, Hae-Jin;Kim, Eun-Kyou
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.43-52
    • /
    • 2004
  • In this paper, the performance of the KOMPSAT-1 orbit determination (OD) accuracy at the ground station was analyzed by using the flight data. The Bayesian least squares estimation was used for the orbit determination and the assessment of the orbit accuracy was evaluated based on orbit overlap comparisons. We also compared the result from OD using GPS navigation solutions with NORAD TLE and the result from OD using range data. Furthermore, the effect of observation type and OBT drift on the accuracy was investigated. As a consequence, It is shown that the OD accuracy using only GPS position data is on the order of 5m RMS (Root Mean Square) with 4 hrs arc overlap for the 30hr arc and the GPS velocity data is not proper as a observation for the OD due to its inferior quality. The significant deterioration of the accuracy due to the critical clock bias was not founded by means of the comparison of OD result from other observations.

Determination of Lead in Urine by Atomic Absorption Spectrophotometry (원자흡광법을 이용한 요중 연 배설량의 정량)

  • Paik, Nam-Won;Yoon, Bock-Sang;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.377-381
    • /
    • 1974
  • Determination of lead in urine is important in industrial hygiene and toxicology. Dithizone method has been principally used for the determination of lead in urine, which gives accurate results in skilful hands but is usually complex and time-consuming. Atomic absorption spectrophotometry is a new simple method and several procedures have been described. However, the influences of pH and the presence of chelating agents during treatment of lead poisoning are not clear. The purpose of this study was to find out the effect of pH and chelating agents on the determination of lead using Shimadzu atomic absorption/flame spectrophotometer, model AA-610. The results obtained were as follows: 1. The atomic absorption spectrophotometry(AAS) could be applied without prior acid digestion to specimens in the absence of chelating agents. The absorbance at $2,170\;{\AA}$, though more sensitive, was more noisy electronically. Therefore, we selected the wavelength of $2,833\;{\AA}$ plus scale expansion. 2. The optimal pH was in the range from 2 to 3. 3. The sensitivity was $0.075{\mu}g/ml/%$ and detection limit was about $0.2{\mu}g/ml$. 4. In the presence of EDTA, lead could not be completely determined without prior acid digestion. 5. On specimens from patients receiving penicillamine therapy, a comparison was made between the values obtained with dithizone method and AAS method with prior acid digestion. The results of comparison showed a very good agreement.

  • PDF

Study on the Determination of Fire Protection Thickness based on Section Factor (강재의 단면형상에 따른 내화피복두께 산정 연구)

  • 정청운;지남용;권인규
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

Determination of Cadmium(II) and Copper(II) by Flame Atomic Absorption Spectrometry after Preconcentration on Column with Pulverized Amberlite XAD-4 with Bismuthiol I

  • Park, Dong-Seok;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1375-1382
    • /
    • 2007
  • A column preconcentration method with pulverized Amberlite XAD-4 loaded with bismuthiol I (BI) has been developed for the determination of trace Cd(II) and Cu(II) in various real samples by flame atomic absorption spectrophotometry. Various experimental conditions, such as the size of XAD-4, adsorption flow rate, amount of bismuthiol I, stirring time for adsorbing bismuthiol I on XAD-4, pH of sample solution, amount of XAD-4- BI, desorption solvent, and desorption flow rate, were optimized. Also, the adsorption capacity and the adsorption rate of Cd(II) and Cu(II) on XAD-4-BI were investigated. The interfering effects of various concomitant ions were investigated, Bi(III), Sn(II) and Fe(III) were found to affect the determination. But the interference by these ions was completely eliminated by adjusting the amount of XAD-4-BI resin to 0.70 g, although the adsorption flow rate was slower. For Cd(II) our proposed technique obtained a dynamic range of 0.5-40 ng mL-1, a correlation coefficient (R2) of 0.9913, and a detection limit of 0.3 ng mL-1. For Cu(II), the corresponding values were 2.0-120 ng mL-1, 0.9921 and 1.02 ng mL-1. To validate this proposed technique, the aqueous samples (stream water, reservoir water, tap water and wastewater), the diluted brass sample and the plastic sample, as real samples, were used. Recovery yields of 91-103% were obtained. These measured data were not different from ICP-MS data at 95% confidence level. Our proposed method was also validated using rice flour CRM (normal, fortified) samples. From the results of our experiment, we found that the technique we present here can be applied to the determination of Cd(II) and Cu(II) in various real samples.

Studies on the Simultaneous Determination of VNA and TSNA by GC - TEA (Gas chromatography-Thermal Energy Analyzer에 의한 휘발성 니트로소아민과 담배 특유의 니트로소아민들의 동시 분석연구)

  • Rhee, Mun-Su;Ji, Sang-Woon;Park, Yang-Su
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 1993
  • This is to investigate the methodology for the simultaneous determination of Wk, mk and TSNA using gas chromatography(GC) in combination with chemiluminescence detector, thermal energy analyzer(TEA) . The simultaneous analysis has been estimated by evaluating tobacco. The TEA was linked to GC equipped with non -polar SPB -5 fused silica capillary column which was introduced into the ceramic pyrolysis tube by the point of 16cm from the end of TEA. Quantification was carried out by internal standardization with WDPA after calibration of retention times and response factors with authentic nitrosoamines. It was demonstrated that WDPA was most preferable as internal standard for the simultaneous analysis. The recoveries of the internal standard were in the range of 83∼96% . Nitrosoamines in this method were detected with determination limit of 0.1ng and was made by a straight line in calibration curve by TEA response. The suitability of nitrosoamines extraction in tobacco leaf was investigated. It was most suitable to extract nitrosoamines from tobacco leaves with 0.01 M NaOH within a period of 8 hours. Thimerosal as an antibacterial agent was added to NaOH solution to prevent artifactual formation. The fractionation and the purification of nitrosoamines form alkaline extracts were conveniently performed using Extrelut multilayer column and dichloromethane. Reproducible and reliable results were obtained for the determination of nitrosamines in a relatively short time compared to previous known method. TSNA contents in burley were about 4 times higher as those in the fluecured tobacco.

  • PDF

A study of determination probability function to the hidden inheritance in SR DEVS (SR DEVS에서 숨겨진 상속에 대한 결정확률 함수의 연구)

  • Park, Sang-Joon;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.1
    • /
    • pp.137-142
    • /
    • 2015
  • In the object inheritance of SR DEVS, partial or overall asset inheritance can be possible. To a asset inherited from parent object, by respective dedicated function a child object can implement partial or whole asset, or not. Even though a child has a inherited asset, if the asset is the hidden property its implementation will not be provided. A inherited asset cannot be showed in whole asset implementation, or it can be implemented by special system state. Here, the whole asset implementation means may include time parameter. In this paper, we describe a determination probability scheme for partial or whole asset inherited from the parent object to determine the hidden inheritance. By the determination probability function it is decided that the inherited asset will be hidden or normal asset.

Genetic Studies on Heading-to-Ripening Period and Its Relationship to Yield Components in Barley I. Studies on maturity criteria in barley (대맥의 등숙일수와 수량구성요소와의 관계에 대한 유전연구 제I보 대맥의 생리적 성숙기 기준 설정)

  • Chun; J.U.;Lee, E.S.;Lee, H.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.1
    • /
    • pp.49-54
    • /
    • 1982
  • Experiments were carried out to establish physiological maturity determination criteria with reference to visibly easy measurement in barley in 1980 at Suweon. Thirty-three cultivars and lines from 500 crossing blocks were classified into 4 heading groups, and 5 variables; moisture content, discoloration of awn, exsertion, lemma and flag leaf were measured. There were highly negative correlations between heading date and ripening periods (r=-0.656$^{**}$ ), so early heading types had longer ripening periods. Comparing with the variables used for maturity determination, moisture content and discoloration of lemma were most sensitive to development of grain-filling. Those two variables, alone or in combination could be used to screen many genotypes of barley for physiological maturity. In determination of maturity with reference to visibly easy measurement, color of lemma changed stably and was the most useful way and discolor of flag leaf increased the accuracy of determination. The color of lemma at this time was Grayish yellow, and the mean moisture content was about 33 percent in 33 barley cultivars and lines.

  • PDF

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

Determination of a Minimum Detectable Activity through a Measurement of Pu Isotopes in Environmental Samples

  • Lee, M. H.;Jung, E. C.;Song, K.S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1162-1166
    • /
    • 2008
  • In this paper, several parameters affecting the sensitivity and determining the minimum detectable activity (MDA) for the measurement of the Pu isotopes were investigated. Among the parameters affecting the determination of the MDA values for the Pu isotopes in the environmental samples, amounts of the samples appeared to be crucial factors in decreasing the MDA values. The MDA for the Pu isotopes in the environmental samples were calculated by varying the counting time of the samples and background. The results obtained in this study can be used for an environmental radiation monitoring program regarding the level of concern for a radionuclide beyond which some action may need to be taken.

Impact of Different Green-Ampt Model Parameters on the Distributed Rainfall-Runoff Model FLO-2D owing to Scale Heterogeneity (분포형 강우-유출 모형에서 토양도 격자크기 효과가 Green-Ampt 모형의 매개변수와 모의된 강우손실에 미치는 영향)

  • Hwang, Ji-hyeong;Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.29 no.1
    • /
    • pp.15-23
    • /
    • 2020
  • The determination of soil characteristics is important in the simulation of rainfall runoff using a distributed FLO-2D model in catchment analysis. Digital maps acquired using remote sensing techniques have been widely used in modern hydrology. However, the determination of a representative parameter with spatial scaling mismatch is difficult. In this investigation, the FLO-2D rainfall-runoff model is utilized in the Yongdam catchment to test sensitivity based on three different methods (mosaic, arithmetic, and predominant) that describe soil surface characteristics in real systems. The results show that the mosaic method is costly, but provides a reasonably realistic description and exhibits superior performance compared to other methods in terms of both the amount and time to peak flow.