• Title/Summary/Keyword: Tilting Center

Search Result 128, Processing Time 0.032 seconds

Effect of Contralateral Hip Adduction on Activity of Lumbar Stabilizers and Pelvic Lateral Tilting During Hip Abduction in Side-Lying

  • Kim, Hyo-Uen;Kwon, Oh-Yun;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.16-21
    • /
    • 2013
  • The purpose of this study was to determine the effect of contralateral hip adduction (CHA) on the muscle activity of lumbar stabilizers and the angle of pelvic lateral tilting during hip abduction in side lying. Twenty healthy male subjects with no medical history of lower extremity or lumbar spine disorders were recruited for the study. Subjects randomly performed preferred hip abduction (PHA) and hip abduction with contralateral hip adduction in side lying. The muscle activities of the dominant side rectus abdominis, external oblique, internal oblique, quadratus lumborum, gluteus medius, and non-dominant side hip adductor longus were measured during PHA and CHA by using a surface electromyography (EMG) system. Pelvic lateral tilting motion was measured by using a three-dimensional motion analysis system. Data on EMG and pelvic motion were collected at the same time during PHA and CHA. A paired t-test was used to compare EMG activity and the angle of pelvic lateral tilting in the two exercises. The study found that the EMG activities of all muscles were more increased significantly in CHA than PHA condition. The angle of pelvic lateral tilting was more decreased significantly in CHA than PHA condition. These findings suggest that CHA could be recommended as a hip abduction exercise for activating lumbar stabilizers and decreasing compensatory pelvic lateral tilting motion.

CAN THE UNIVERSE BE "TILTED"?

  • La, Daile
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.19-23
    • /
    • 1992
  • We investigated the "tilting" of the Universe, i.e., a non-Doppler origin of the dipole moment of the cosmic background radiation (CBR). Superhorizon-sized isocurvature, rotational and true vacuum bubble perturbations are considered. We show that the more natural way of the "tilting" the Universe is via the true vacuum bubble perturbation. Nevertheless, due to the small filling fraction of the bubbles of viable extended inflationary models, we find that the probability of the real occurrence in the Universe is quite insignificant.

  • PDF

Hovering Performance Improvement by Modifying COG of Underwater Robotic Platform (수중운항로봇 플랫폼의 무게중심 조정을 통한 제어성능 향상)

  • Bak, Jeongae;Kim, Jong-Won;Jin, Sangrok;Kim, Jongwon;Seo, TaeWon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.661-666
    • /
    • 2015
  • This paper presents control performance improvement by modifying center of gravity (COG) of an underwater robotic platform. To reduce the oscillation or to increase the positioning accuracy, it is important to accurately know the COG of an underwater robotic platform. The COG is determined by the three measured tilting angles of the platform in different postures. The tilting angle is measured while the platform is hanged by two strings. Using coordinate transformation, the plane of intersection is defined from the angle of the platform and the position of the string. The COG of the robotic platform is directly calculated by the intersected point in three defined planes. The measured COG is implemented to the control algorithm that is pre-designed in the previous research, and the empirical result on tilting gives 48.26% improved oscillation performance comparing to the oscillation result with the ideal COG position.

Sensitivity analysis for optimizing the suspension system of the tilting train (틸팅 열차의 현가장치 최적화를 위한 민감도 분석)

  • Kim, Jeong-Beom;Park, Tae-Won;Yoon, Ji-Won;Kim, Nam-Po;Kim, Young-Mo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2151-2155
    • /
    • 2008
  • The tilting train express (TTX) is able to tilt its body toward to the center of the turning radius on curved railways. TTX can travel at higher speed than the existing normal railway vehicles due to the tilting mechanism decreasing centrifugal force. Also, a new suspension system is required for TTX which has proper stiffness constants and damping ratios because it has different suspension characteristics with the others. Therefore, the suspension systems need to be optimized to maximize dynamic characteristic of the railway vehicle. To optimize the dynamic characteristics of TTX, sensitivity analysis should be onde to identify design variables. In this paper, Design of Experiments(DOE) is used for the sensitivity analysis of TTX.

  • PDF

Development of Anti-fluttering Tilting Pad Journal Bearing with the Shape Modification of Upper Pad (상부패드의 형상 변경을 통한 'Anti-fluttering 틸팅패드 저널베어링' 개발)

  • Yang Seong-Heon;Nah Un-Hak;Park Heui-Joo;Kim Chae-Sil
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.796-805
    • /
    • 2005
  • The tilting pad journal bearings have been widely used to support high pressure/high rotating turbine rotors owing to their inherent dynamic stability characteristics. However, fatigue damages in the upper unloaded pads and the break of locking pins etc. by pad fluttering are continuously taken place in the actual steam turbines. The purpose of this paper is to develop a new bearing model that can prevent bearing problems effectively by pad fluttering in a tilting pad journal bearing. A new bearing model which has a wedged groove is suggested from the studies of fluttering mechanism performed by previously research works. The fluttering characteristics of the upper unloaded pad are studied experimentally in order to verify the reliability of a new bearing model. It can be known that the phenomenon of pad fluttering nearly does not occurred in the new bearing model under the various experimental conditions. And it is observed that any kinds of bearing failures by pad fluttering does not detect in the application of acture steam turbines.

  • PDF

Analysis of Tilting Pad Journal Bearings Considering Pivot Stiffness (피봇 강성을 고려한 틸팅 패드 저널 베어링의 해석)

  • Choi, Tae Gyu;Kim, Tae Ho
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.77-85
    • /
    • 2014
  • This study set out to predict the load capacity and rotordynamic coefficients of tilting-pad journal bearings, taking the pivot stiffness into account. The analysis uses rocker-back (cylindrical) and ball in socket (spherical) pivot models, both of which are based on Hertzian contact stress theory. The models ascertain the non-linear elastic deformation of the pivots according to the applied load, pivot geometry, and material properties. At present, the Reynolds equation for an isothermal, isoviscous, and incompressible fluid is used to calculate the film pressure by using the finite-element method, after which the Newton-Raphson method is used to simultaneously find the journal center location, pad angles, and pivot deflections. The bearing analysis, excluding the pivot models, is validated using predictions those are readily available in the literature. As the rotor speed increases, the predicted journal eccentricity and damping coefficients decrease, but the stiffness coefficients increase, as expected. Most importantly, the implementation of the pivot models increases the journal eccentricity but significantly decreases the stiffness and damping coefficients of the tilting-pad journal bearings.

Water Lubricated Guide Bearing with Self-aligning Segments

  • Oguma, Tadashi;Nakagawa, Naritoshi;Mikami, Makoto;Thantrong, Long;Kizaki, Yasumi;Takimoto, Fumio
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.2
    • /
    • pp.49-55
    • /
    • 2013
  • Water lubricated guide bearing was newly released and has been applied to actual hydro turbines with vertical shaft. As a result, they can have not only high bearing performance but environmental advantages in meeting the demand for reducing river pollution by oil leakage from oil lubricated guide bearing. The PTFE composite guide bearing was tested by experimental equipment operated under conditions similar to those of actual hydro turbines. Circumferential and axial tilting bearing segments help to improve the bearing performance and efficiency due to low friction loss in the bearing system. Furthermore, bearing cooling systems could be eliminated and maintenance periods could be extended, thus the initial investment and operating costs of the hydroelectric power plant are reduced.

A New Training System for Improving Postural Balance Using a Tilting Bed

  • Yu, Chang-Ho;Kwon, Tae-Kyu;Ryu, Mun-Ho;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.117-126
    • /
    • 2007
  • In this paper, we propose an early rehabilitation training system for the improvement of postural balance with multi-modality on a tilting bed. The integration of the visual, somatosensory and vestibular functions is significant to for maintaining the postural control of the human body. However, conventional rehabilitation systems do not provide multi-modality to trainees. We analyzed the characterization of postural control at different tilt angles of an early rehabilitation training system, which consists of a tilting bed, a visual feedback, a computer interface, a computer, and a force plate. The software that we developed for the system consists of the training programs and the analysis programs. To evaluate the characterization of postural control, we conducted the first evaluation before the beginning of the training. In the following four weeks, 12 healthy young and 5 healthy elderly subjects were trained to improve postural control using the training programs with the tilting bed. After four weeks of training, we conducted the second evaluation. The analysis programs assess (center of pressure) COP moving time, COP maintaining time, and mean absolute deviation of the trace before and after training at different tilt angles on the bed. After 4 weeks, the COP moving time was reduced, the COP maintaining time was lengthened, and the mean absolute deviation of the trace was lowered through the repeated use of vertical, horizontal, dynamic circle movement training programs. These results show that this system improves postural balance and could be applied to clinical use as an effective training system.

Proposal of CT Simulator Quality Assurance Items (전산화단층 모의치료장치의 정도관리 항목 제안)

  • Kim, Yon-Lae;Yoon, Young-Woo;Jung, Jae-Yong;Lee, Jeong-Woo;Chung, Jin-Beom
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

Development of Detachable IORT Table for Colorectal Cancer (장착-탈거 및 경사각 조절이 가능한 대장직장암의 수술 중 방사선 치료대의 개발)

  • Kim, Myung-Se;Lee, Joon-Ha
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.117-121
    • /
    • 1994
  • In spite of remarkable improvement of surgical skills and anesthesia, local failure still occurred in 36-45$ \% $ of locally advanced colorectal cancer after curative resection with or without pre-or post-operative irradiation. Intraoperative radiation therapy(IORT) is the ideal modality which resectable lesions are removed surgically 3nd the remaining cancer nests are sterilized by irradiation during a surgical procedure. Therefore, the excellent local control without the damage of the adjacent normal tissues can be achieved. In IORT, judicious set up of the treatment cone on the treatment surface of the patient is required for accurate and homogenous dose distribution within treatment field, especially on the slopping surface of sacrum and pelvic sidewall which are the common sites of the local recurrence in rectal cancer. For this purpose, adequate co-ordination of gantry rotation and table tilting are essential. Adjusting gantry rotation is not difficult but tilting of the table is impossible inconventional treatment couch. Department of Therapeutic Radiology in Yeungnam University Medical Center developed the IORT table for colorectal cancer which is easy to set up and detach on the Linac treatment couch within 5 minutes. The range of tilting with head-up and head-down is about 30 degree which is efficient and easy-to-use, not only for IORT but also for colorectal surgery. So far, authors performed IORT with newly developed treatment table in 2 patients with rectal cancer and we found that this newly developed table could contribute in improving the dose distribution of IORT and surgical procedure for colorectal cancer.

  • PDF