• Title/Summary/Keyword: Tibial tunnel widening

Search Result 5, Processing Time 0.017 seconds

Rigidfix 와 Infrafix 로 고정한 슬괵건을 이용한 전방 십자인대 재건술 후 경골터널의 확장

  • Choi, Nam-Hong;Jung, Yoo-Hoon
    • 대한관절경학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.153-153
    • /
    • 2009
  • The purpose of this study was to evaluate tibial tunnel widening prospectively after anterior cruciate ligament (ACL) reconstruction with hamstring tendon grafts using Rigidfix (DePuy Mitek, Raynham, MA) femoral fixation and Intrafix (DePuy Mitek) tibial fixation. 56 consecutive patients who underwent ACL reconstruction with a minimum of 2 years' postoperative evaluation were reviewed. On the anterior-posterior (AP) and lateral radiographs, the diameter of the tibial tunnel was measured at proximal, middle, and distal positions and the shape of the tibial tunnels were classified. Tunnel widening was defined as widening of greater than 2 mm. Group I was defined as cases with no tunnel widening and group II defined as cases with tunnel widening. Postoperative laxity evaluations were performed using Lachman test, pivot-shift test, and Instrumented laxity testing using the KT-1000 arthrometer. On the AP radiographs, the average diameter of the tibial tunnel increased 8.8% at 6 months and 8.5% at 12 months postoperatively compared to the immediate postoperative day. On the lateral radiographs, the average diameter of the tibial tunnel increased 7.2% at 6 months and 8.1% at 12 months year postoperatively compared to the immediate postoperative day. The tunnel shape evaluation revealed predominantly linear type in 53 patients (95%). Group I was 42 patients (75%) and group II was 14 (25%). The average KT-1000 measurement was 1.0~1.8 mm in group I and 2.1~2.8 mm in group II (p>0.05) The Lachman and pivot-shift showed tests no significant differences between the two groups. In conclusion, hamstring ACL reconstruction using Rigidfix and Intrafix fixation showed less widening of the tibial tunnels than observed in previously published studies.

  • PDF

Significance of tibial intra-tunnel fixation at Arthroscopic ACL Reconstruction with hamstring tendon (Second-look Arthroscopic Evalution) (자가 슬괵건을 이용한 전방 십자인대 재건술시 경골측 골 터널내 고정의 의의 (이차관절경 검사의 평가))

  • Kim, Young-Chang ;Seo, Seung-Suk;Jung, Kyung-Chil;Gwak, Hey-Chul;Kim, Yoon-Jun;Kim, Jin-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 2006
  • Purpose: The purpose of this study is to evaluate the effects of intratunnel fixation in the tibial side on the arthroscopic ACL reconstruction with quadruple hamstring tendon at the second look arthroscopy. Materials and Method: From Dec 1999 to May 2005, we arthroscopically reexamined 32 cases who had been done arthroscopic ACL reconstruction with quadruple hamstring tendons. Hamstring tendons of all cases were fixed at femoral side with RigidfixTM. At the tibial side hamstring tendons were fixed only Post-tie (Group I) or Post-tie combined with IntrafixTM (Group II). At the time of second look arthroscopy mean age of cases was 30 years and mean duration for second look arthroscopy was 21.3 months. We analyzed the results with IKDC score, KT-1000 arthrometer under anesthesia, Telos stress radiography, tibial tunnel widening on the radiography and second look arthroscopic findings. Results: Group II had more superior than group I at side to side differences with KT-1000 and Telos stress radiograph, IKDC score, but the differences were insignificant. At arthroscopic evaluation, Group ll also had more superior than group I at graft tension and graft appearance, graft synovialization, but the differences were insignificant. Tibial tunnel widening in the knee AP radiograph was 2.3 mm in Group I and 1.7 mm in Group II and the difference was significant. (P=0.042) Conclusions: Additional procedure of tibial intratunnel fixation in arthroscopic ACL reconstruction with autogenous hamstring tendon significantly prohibited from tibial tunnel widening but clinical results, radiologic joint stability, findings in second look arthroscopy were insignificantly different. We concluded that Post-tie itself induced satisfactory clinical results, joint stability and graft maturation and that tibial tunnel widening did not affect the results.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF