• Title/Summary/Keyword: Tibial bone length

Search Result 32, Processing Time 0.027 seconds

Effects of Herbal-Acupuncture with Evodiae Fructus at KI10 on Osteoporosis in Ovariectomized Mice (음곡(陰谷) 오수유(吳茱萸) 약침(藥鍼)이 난소적출(卵巢摘出)생쥐의 골다공증(骨多孔症)에 미치는 영향(影響))

  • Choi, Sung-Hoon;Lee, Byung-Ryul;Yang, Gi-Young;Kim, Jae-Kue;Seo, Young-Suk;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.217-242
    • /
    • 2010
  • Objective : This study is aimed to evaluate the effects of Evodiae Fructus herbal-acupuncture (EF-HA) at KI10 on osteoporosis induced by ovariectomy in mice. Method : Mice underwent bilateral ovariectomy. After recovering, the ovariectomized (OVX) mice were treated by needle prick, saline injection, herbal acupuncture with Evodiae Fructus (EF-HA) at KI10 for 8 weeks. Result : 1. EF-HA at KI10 significantly inhibited the overgrowth of tibia in ovariectomized mice. 2. NP at KI10 significantly restored the tibial BMD (bone mineral density) in ovariectomized mice. 3. EF-HA at KI10 significantly restored the phosphorus and creatinine levels in ovariectomized mice serum. 4. EF-HA at KI10 significantly restored the tibial Ca and P levels in ovariectomized mice. 5. EF-HA at KI10 significantly reduced the tibial osteoclast-like cells in ovariectomized mice. 6. EF-HA at KI10 significantly inhibited the overgrowth of tibial GPL (growth plate length) in ovariectomized mice. Conclusion : EF-HA at KI10 has protective and therapeutic effect for osteoporosis in ovariectomized mice. Thus, it is suggested that EF-HA can be an useful therapeutics in clinical field after further researches.

A HISTOLOGIC STUDY OF BONE FORMATION ACCORDING TO DIFFERENT CRYOPROTECTANTS DURING CRYOPRESERVATION OF BONE (동결보호제의 종류에 따른 냉동보관자가골의 골형성능에 대한 연구)

  • Park, Hyun-Wook;Lee, Baek-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.228-238
    • /
    • 2005
  • Purpose: Several cryoprotectants are in use to help the survival of cells during cryopreservation of bone in maxillofacial region. Among them, $Me_2SO$(dimethyl sulfoxide), EG(ethylene glycol), sucrose were used for experimentally created defects with accompanying cryopreserved bone graft in the rabbit model. The aim of this study is to analyze the effect of above mentioned agents on bone formation using histologic and histomorphometrical methods, thus to provide experimental support for clinical application of these agents. Materials and methods: Nine rabbits were used as experimental animals. Surgical defects were created on the distal femoral heads and mesial tibial heads of each animal using trephine drill(5mm diameter and 5mm length). The harvested bones were cryopreserved in $-80^{\circ}C$ refrigerator for one week. The defects were filled with cryopreserved bone with cryoprotectants as experimental groups and cryopreserved bone without cryoprotectant as control. Then, the animals were sacrificed at 1, 2, and 3 weeks after surgery. With Goldner's modified Masson trichrome staining and semiautomatic image analysis system, we observed the change of the cells and bone formation. Results: After bone graft, bone formation and active remodeling process were examined in all experimental groups and the control. But the intensity of such activities of the control were somewhat weaker than that of the experiments. Especially $Me_2SO$+sucrose group was the best in bone formation and bone remodeling. $Me_2SO$ group was more than that of EG group in bone fomation. Sucrose seems to be helpful in survival of the bone cell. Histologic findings showed superior bony quantity and quality in experimental groups than that in control. Conclusions: The data from this study provides the basis for future studies for evaluating the effect of cryoprotectants in the cryopreservation of bone and clinical study for predictable use of these agents.

THREE DIMENSIONAL LINEAR MEASUREMENT OF PROXIMAL TIBIA IN MEDIAL AND LATERAL APPROACH FOR BONE HARVESTING (경골 근위부 골채취를 위한 내측 및 외측 접근법시의 삼차원적 길이계측)

  • Nam, Woong;Park, Won-Se;Jeong, Ho-Gul;Hu, Kyung-Seok;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.307-311
    • /
    • 2007
  • Purpose: The aim of this study was simply assessing linear measurements in the lateral and medial approach, respectively, for bone harvesting using anatomic and three-dimensional(3D) computed tomographic(CT) analyses on a dried cadaveric proximal tibia. In addition, the availability of the three-dimensional computed tomographic(3D-CT) analysis was also estimated. Materials and methods: Ten dried proximal tibia were obtained from five Korean cadavers. Four the reference points, the SM(superior-medial), IM(inferior-medial), SL(superior-lateral), and IL(inferior-lateral) were marked around the tibial tuberosity. The PM(posterior-medial) and PL(posterior-lateral) points were randomly marked at points farthest from the lateral and medial reference points, respectively, in the posterior border of the superior articular surface of both condyles. All measurements were obtained on the dried proximal tibia. After computed tomography had been performed, the three dimensional images were reconstructed using V works $4.0^{TM}$(Cybermed Inc., Seoul, Korea), and the length between the reference points were measured three dimensionally using the method described above. The error between the mean actual and mean 3D-CT measurements was calculated in order to determine the availability of the three dimensional computed tomographic analysis. Results: The length between the reference points was greatest at the IL-PM, which averaged $65.39mm{\pm}10.35$. This was followed by the SL-PM with $63.24mm{\pm}8.10$, the IM-PL with $58.09mm{\pm}10.02$, and the SM-PL with $51.99mm{\pm}9.06$. The differences between the IL-PM and SM-PL were 13.4 mm. The mean values were 55.04 mm in the medial approach and 64.32 mm in the lateral approach, and the differences between medial and lateral were 9.28 mm. The error between the mean actual and mean 3D-CT measurements was 0.31% and the standard deviation was 0.28%. Conclusion: The anatomical and three dimensional computed tomographic analysis indicates that there was only a 9.28 mm linear difference between the lateral and medial approach. This is consistent with previous studies, which showed that there was little difference between the two approaches in terms of the bone volume. In addition, the error(0.31%) and the standard deviation(0.28%) were considered low, demonstrating high accuracy of 3D-CT. Therefore it can be used in preoperative treatment planning.

The Experimental Study of Effects of Irradiation on Osseointegration (방사선조사가 임프란트의 골유착에 미치는 영향에 관한 실험적 연구)

  • Park Kwan-Soo;Lee Sang-Rae;Hwang Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.119-147
    • /
    • 1999
  • The purpose of this study was to investigate the effects of the Co-60 γ irradiation on the osseointegration. 2.0 mm titanium alloy screw implants(Sankin Industry Co. Ltd., Japan) were placed in the tibial metaphysis of the rabbits, bilaterally. The mean length of the implants was 6.0 mm. The right tibia was irradiated with a single dose of 15Gy from 60Co teletherapic machine at 5th postoperative day. The experimental group was irradiated tibia. The control group was non­irradiated tibia. To observe the phase of bone formation, the bone labeling by intramuscular injection of 20mg/Kg of Tetracycline, Calcein, Alizarin red S, was performed. The rabbits were sacrificed on the 1st, 2nd, 4th, 6th, 8th week and the tibia including implants were taken, and then the specimens were examined by the microradiography, light microscopy, and fluorescent microscopy. The obtained results were as follows: 1. There were connective tissue between bone and titanium at 1st week, in both group. Especially, the many empty lacunae without nucleus and obscure cytoplasm in experimental group, were observed. 2. The osteons were observed at 4th week in control group, and at 6th week in experimental group. The bone formation in experimental group was retarded as compared to the control group. 3. In fluorescent microscopy, bone labelling band was observed as linear, arc or concentric shape. Occasionary interrupted labelling band was observed, which is demonstrated bone remodeling. 4. In microradiographic examination, the radiolucent image was found between bone and implant with widening of bone marrow spaces as compared to the control group.

  • PDF

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Juvenile Hemangioma Occurred in Distal Femoral Epiphysis (소아의 대퇴골 원위부 골단에 발생한 혈관종)

  • Kim, Tai-Seung;Lee, Chang-Hoon;Park, Chan-Keum
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.37-41
    • /
    • 2010
  • A hemangioma occurred in the bony epiphysis is extremly rare. A 5-year-old boy visited to our hospital with pain and flexion contracture on the right knee. MRI showed some lesions scattered in the epiphysis of the distal femur and the proximal tibia. Biopsy specimen from the distal femoral epiphysis revealed pathologic findings compatible with hemangioma. On 8 years follow-up, the lesion in the distal femoral epiphysis had been cured, and those in the proximal tibial epiphysis were spontaneously disappeared without surgery. The scanogram shows no leg length discrepancy and angular deformity. We reports a rare case of hemangioma occurred in the bony epiphysis with the results of 8 year follow-up with the review of literatures.

Free Vascularized Osteocutaneous Fibular Graft to the Tibia (경골에 시행한 유리 생 비골 및 피부편 이식)

  • Lee, Kwang-Suk;Park, Jong-Woong;Ha, Kyoung-Hwan;Han, Sang-Seok
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.63-72
    • /
    • 1997
  • We have evaluated the clinical results following the 46 cases of free vascularized osteocutaneous fibular flap transfer to the tibial defect combined with skin and soft tissue defect, which were performed from May 1982 to January 1997. Regarding to the operation, flap size, length of the grafted fibula, anastomosed vessels, ischemic time of the flap and total operation time were measured. After the operation, time to union of grafted fibula and the amount of hypertrophy of grafted fibula were periodically measured through the serial X-ray follow-up and also the complications and results of treatment were evaluated. In the 46 consecutive procedures of free vascularized osteocutaneous fibular flap transfer, initial bony union were obtained in the 43 grafted fibulas at average 3.75 months after the operation. There were 2 cases in delayed unions and 1 in nonunion. 44 cutaneous flaps among the 46 cases were survived but 2 cases were necrotized due to deep infection and venous insufficiency. One necrotized flap was treated with latissimus dorsi free flap transfer and the other was treated with soleus muscle rotational flap. Grafted fibulas have been hypertrophied during the follow-up periods. The fracture of grafted fibula(15 cases) was the most common complication and occurred at average 9.7 months after the operation. The fractured fibulas were treated with the cast immobilization or internal fixation with conventional cancellous bone graft. In the cases of tibia and fibula fracture at recipient site, the initial rigid fixation for the fibula fracture at recipient site could prevent the fracture of grafted fibula to the tibia.

  • PDF

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA (가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가)

  • Kwak Myeong-Bae;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.

THE EFFECT OF VARIOUS SURFACE TREATMENT METHODS ON THE OSSEOINTEGRATION (임플랜트의 표면처리 방법이 골유착에 미치는 영향에 관한 연구)

  • Choi Jeong-Won;Kim Kwang-Nam;Heo Seong-Joo;Chang Ik-Tae;Han Chong-Hyun;Baek Hong-Gu;Choi Yong-Chang;Wennerberg Ann
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.71-83
    • /
    • 2001
  • The purpose of this study was to compare the effects of various surface treatments by measuring removal torque on bone healing around titanium implants. 40 Screw-shaped cp titanium implants with length of 4mm, outer diameter of 3.75mm, and pitch-height of 0.5mm were used Group 1 was left as machined(control), Group 2 was blasted with $50{\mu}m\;Al_2O_3$, group 3 was blasted and etched in etching solution($NH_4OH : H_2O_2:H_2O= 1 : 1 : 5$) at $90^{\circ}C$ for 1 minute group 4 was blasted and oxidated under pure oxygen at $800^{\circ}C$. The implant surface roughness was analyzed with SEM and CLSM(Confocal Laser Scanning Microscope) and implants were placed in proximal tibial metaphysis of 10 New Zealand White rabbits. After 3 months of healing period, removal torque of each implant was measured to compare bone healing around implant. The results obtained were as follows 1. In SEM view, blasting increased the roughness of the surface, but etching of that rough surface decreased the roughness due to the removal of the tip of the peak. Oxidation also decreased the roughness due to formation of needle-like oxide grains on the implant surface. 2. The Sa value from CLSM was least in the machined group($0.47{\mu}m$), greatest in blasted group($1.25{\mu}m$), and the value decreased after etching($0.91{\mu}m$) and oxidation($0.94{\mu}m$). 3. The removal torque of etched group(24.5Ncm) was greater than that of machined group(16.7Ncm) (P<0.05), and was greatest in the oxidated group(40.3Ncm) and the blasted group(34.7Ncm).

  • PDF