• Title/Summary/Keyword: Tibial Characteristics

Search Result 36, Processing Time 0.025 seconds

Fracture analysis of wild mammals in South Korea

  • Jang, Hyunkyu;Park, Jong-Moon;Ahmed, Sohail;Seok, Seong-Hoon;Kim, Ho-Su;Yeon, Seong-Chan
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.4
    • /
    • pp.175-180
    • /
    • 2019
  • This study was conducted to evaluate and analyze fractures types in wild mammals in Korea. Wild mammals treated at 3 wildlife centers in Korea were included. Of the 63 cases included in this study, water deer was the most common species encountered with fractures. We determined 85 different fracture sites, with maximum lumber vertebral fractures followed by femoral, tibial and pelvic fractures. External skeletal fixator (ESF)-intramedullary (IM) pin (IM+ESF tie-in fixation) was the most common method applied for the surgical treatment of mammals. Lumbar vertebrae and femur were the most common bones involved. The findings of this study are expected to provide information for veterinarians regarding the frequency and characteristics of fractures in wild mammals and serve as a basic database for the types and outcomes of fractures in wild mammals.

Effect of Eversion Characteristics on Knee and Ankle Joint of Trans-tibial Amputees (인공의족의 외반 특성이 하퇴절단자의 무릎과 발목에 미치는 영향)

  • Bae, Tae-Soo;Chang, Yun-Hee;Kim, Shin-Ki;Mun, Mu-Seung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.886-891
    • /
    • 2009
  • One of the important functions of prosthetic foot is the foot inversion-eversion which is so important when walking on uneven surfaces. The aim of our study was to evaluate the effect of foot eversion angle especially on knee and ankle joint for transtibial amputees by motion analysis. The experimental data were collected from three transtibial amputees and then ten healthy individuals. To simulate walking on side sloping ground, we used custom-made slope (5, 10, 15 degrees). Motion analysis was performed by 3-dimensional motion analyzer for 6 dynamic prosthetic feet. The results showed that knee abduction moments of amputated leg were decreased but those of sound leg were mainly increased as foot eversion angle increased. And ankle abduction moments of sound leg were inconsistent in magnitude and tendency between control and experimental group. Therefore foot eversioncharacteristics should be considered to develop advanced prosthetic foot.

Revascularization of Popliteal Artery Injury in Trauma Around Knee Joint (슬관절주위 외상에 의한 슬와동맥 손상의 재혈관화)

  • Han, Soo-Hong;Shin, Dong-Eun;Dan, Jin-Myung;Kim, Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • Popliteal artery injury in blunt trauma of knee joint is not common but poses high rate of amputation due to anatomical characteristics or delayed diagnosis and treatment. The aim of the present study is to review the authors' experiences with this condition and identify factors contributing to disability. We reviewed 7 cases of popliteal artery injury in trauma around knee. Injury mechanism, type of vessel damage, associated injuries, mangled extremity severity scores (MESS), ischemic time and additional treatments were analyzed. Tibial fracture, distal femoral fracture and serious soft tissue defect were combined. Mean MESS was 9.9 point and mean time of revascularization was 7.1 hours. Transfemoral amputation was performed in 2 cases due to vascular insufficiency and devastating infection, and 4 patients were able to walk without any support at the last follow up. Age, the severity of soft tissue injury, ischemic time and MESS are thought to be related to prognosis, and young patients with short ischemic time show best results, but authors experienced one exceptional case. We have to consider multiple factors related to the prognosis in popliteal artery injury with fractures around knee, and careful decision is needed regarding to early amputation.

  • PDF

Clinical Characteristics of Sound Dogs with Medial Patellar Luxation

  • Kim, Gi-Na;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • The purpose of this study is to identify clinical features of sound (non-lame) dogs with medial patellar luxation (MPL). Medical records of 72 dogs diagnosed with MPL were retrospectively reviewed. There were no significances in breed, sex, body weight, body condition score (BCS), osteoarthritis (OA) score, inclination of the femoral head angle (IFA), and mechanical medial proximal tibial angle (mMPTA) between sound and lame dogs, respectively. The mean age of sound dogs was significantly higher than that of lame dogs (P < 0.05), especially in MPL grade 3. The frequency of sound dogs with MPL grade 1 and 2 was 2.3 times higher than that of sound dogs with MPL grade 3 and 4 (P < 0.05). The anatomical lateral distal femoral angle (aLDFA) of sound dogs was significantly lower than that of lame dogs (P < 0.05). However, there were no statistical differences in aLDFA between sound and lame dogs in MPL grade 1, 2, and 4, except for MPL grade 3. This study suggests that in case of MPL grade 1 and 2, frequency of sound dogs is significantly high, and also that in MPL grade 3, if mean ± (standard deviation) age of the dogs is 7.4 ± 3.6 years old and the aLDFA is 105.6 ± 4.1 degrees, they are very highly possible to be sound dogs.

Histomorphometric analysis of microcrack healing after the installation of mini-implants

  • Shin, Soobin;Park, Pan-Soo;Baek, Seung-Hak;Yang, Il-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.62-68
    • /
    • 2015
  • Purpose: The goal of this study was to investigate the histomorphometric characteristics of the healing process of microcracks in the cortical bone after the installation of mini-implants (MIs). Methods: Self-drilling MIs were inserted into the tibial diaphysis of twelve adult male New Zealand rabbits. Four MIs per rabbit were placed randomly. The animals were divided into four groups according to the length of the healing period: group A was sacrificed immediately, group B was sacrificed after one week, group C was sacrificed after two weeks, and group D was sacrificed after four weeks. Cortical bone thickness was measured using micro-computed tomography, and histomorphometric analyses of the cumulative length of the microcracks (CLCr) and the total number of microcracks (NCr) were performed using hematoxylin and eosin staining. Results: The microcracks were radially and concentrically aligned in the peri-MI bone. The CLCr decreased significantly one week after the surgery, mainly due to healing of the concentrically aligned microcracks. The CLCr showed another significant decrease from two weeks after the surgery to four weeks after the surgery, mainly reflecting healing of the radially aligned microcracks. A statistically significant decrease in the NCr occurred as the microcracks healed from zero weeks to two weeks. However, no significant difference in the NCr was found between groups C and D. Conclusions: In order to improve the primary stability of MIs, delayed loading and a healing period of a certain length are recommended to ensure the optimal healing of microcracks and bone remodeling.

Biomechanical evaluation of a bioactive artificial anterior cruciate ligament

  • Guerard, Sandra;Manassero, Mathieu;Viateau, Veronique;Migonney, Veronique;Skalli, Wafa;Mitton, David
    • Advances in biomechanics and applications
    • /
    • v.1 no.4
    • /
    • pp.239-252
    • /
    • 2014
  • This study aimed to assess the biomechanical performance of a new generation of artificial ligament, which can be considered "bioactive" and "biointegrated," implanted in sheep. Thirty sheep were implanted: 15 sheep received the artificial ligament grafted with a bioactive polymer (grafted) and 15 received the artificial ligament without a bioactive polymer (non-grafted). The animals were sacrificed 3 or 12 months after implantation. The knee kinematics, namely flexion-extension, anterior drawer, and varus-valgus tests, were evaluated using a fully characterized custom-made device. Afterward, the specimens were tested under uniaxial tension until failure. The flexion-extension showed significant differences between (grafted or non-grafted) artificial and native ligaments 3 months after implantation. This difference became non-significant 12 months postoperatively. The anterior tibial drawer was significantly increased 3 months after implantation and remained significantly different only for non-grafted ligament 12 months after implantation. Twelve months after implantation, the differences between grafted and non-grafted ligament biomechanical properties were significant in terms of stiffness. In terms of load to failure, grafted ligaments seem to have had slightly better performance than non-grafted ligaments 12 months postoperatively. Overall these results suggest that grafted artificial ligaments have slightly better biomechanical characteristics than non-grafted artificial ligaments 12 months after implantation in sheep.

Clinical and Electrophysiological Characteristics of the Patient with 'Mononeuropathy multiplex' (다발성 단신경병증의 임상적, 전기생리학적 특성)

  • Park, Kyung-Seok;Chung, Jae-Myun;Park, Seong-Ho;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.34-37
    • /
    • 2002
  • Background : The term "mononeuropathy multiplex" means simultaneous or sequential involvement of individual noncontiguous nerve trunks, evolving over days to years. The aim of this study was to delineate the causes, clinical features, and detailed electrophysiological findings in the patients with mononeuropathy multiplex. Methods : We analyzed the medical records of 22 patients with mononeuropathy multiplex confirmed on electrophysiological studies in Inje University Seoul Paik Hospital, Seoul Municipal Boramae Hospital, and Seoul National University Hospital between 1991 to 2000. Results : The number of male and female patients was equal. The mean age was 48 years with a peak incidence in the sixth decade. The etiology could be divided into vasculitis(11 patients) or non-vasculitis group. In vasculitis group, Churg-Strauss syndrome, polyarteritis nodosa, and rheumatoid arthritis were included. The non-vasculitis group included diabetes mellitus, leprosy, and Guillain-Barre syndrome. Ulnar and median nerves were most commonly involved(91%). In descending order of frequency, peroneal, posterior tibial, sural, and radial nerves were also involved. Bilateral involvement occurred most commonly in ulnar nerve. The symptoms and signs of mononeuropathy multiplex were the initial manifestations in 12 patients(55%), which was more frequent in vasculitis group(73%). Nerve conduction abnormalities could be divided into axonal, demyelinating, or mixed type. Most(91%) of the patients in vasculitis group revealed axonal type abnormalities. The location of the nerve lesion was frequently related to potential site of entrapment in demyelinating type. Conclusions : Mononeuropathy multiplex is the presenting features of the etiological disease frequently, especially in vasculitis group. Nerve conduction studies(NCS) reveals not only axonal type but also demyelinating type abnormalities. The etiological diseases were different in each type. Therefore, NCS is very helpful for the early etiological diagnosis and therapeutic implication in the patients with mononeuropathy multiplex.

  • PDF

The Concepts of Montage in Somatosensory Evoked Potentials (체성감각 유발 전위에서 montage에 대한 개념)

  • Cha, Jae-Kwan;Kim, Seung-Hyun
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.160-167
    • /
    • 1999
  • Although somatosensory evoked potentials(SSEPs) have been utilized as the useful diagnostic tools in evaluating the wide variety of pathological conditions, such as focal lesions affecting the somatosensory pathways, demyelinating diseases, and detecting the clinically occult abnormality, their neural generators is still considerably uncertain. To appreciate the basis for uncertainties about the origins of SSEPs, consider criteria that must be met to establish a causal relationship between activity in a neural structure and a spine/ scalp-recorded potential. Electrode locations and channel derivations for SSEPs recordings are based on two principles:(1) the waveforms are best recorded from electrode sites on the body surface closest to the presumed generator sources along the somatosensory pathways, and(2) studies of the potential-field distribution of each waveform of interest dictate the best techniques to be used. In this article, authors will describe followings focused on ;(1) the concepts of near field potentials(NFPs) and far field potentials(FFPs) - the voltage of NFPs is highly dependent upon recording electrode position, FFPs are unlike NFPs in that they are widely distributed, their latencies and amplitudes are independent of recording electrode.(2) appropriate montage settings to detect the significant potentials in the median nerve and posterior tibial nerve SSEPs(3) neural generators of various potentials(P9, N13, P14, N18, N20, P37) and their clinical significance in interpretating the results of SSEPs. Especially, Characteristics of N18(longduration, small superimposed inflection) suggested that N18 is a complex wave with multiple generators including brainstem structures and thalamic nuclei. And N18 might be used as the parameter of braindeath. Precise understanding on these facts provide an adequate basis utilizing SSEPs for numerous clinical purposes.

  • PDF

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

Electromyographic Study of Lumbosacral Radiculopathy by Lumbar Disc (요추 추간원판에 의한 요천추 선경근 병변의 근전도 연구)

  • Kim Ho-Bong;Lee Jin-Hee;Kim Jong-Youl;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.3
    • /
    • pp.1-12
    • /
    • 1999
  • The aim of this study is to examine the sensitivity and characteristics of electromyography abnormalities detected by using various paramenters in patients with lumbosacral radiculopathies. EMG is widely used for disgnosing and localizing the level of radiculopathy. The results of the study were as follow : 1. In electromyography, L5 radiculopathy usa 95 cases(51.690). S1 radiculopathy was $45m(24.5\%)$ L4 radiculopathy was 18cases $(9.8\%)$, and L2, 3 radiculopathy was 8cases$(4.3\%)$. Remains 18cases$(9.8\%)$ had no definite radiculopathy. 2. Peroneal and tibial motor nerve conduction velocity studies were not significant as compared to the side to side. 3. Latency of H-reflex in L5 radiculopathy was $30.55\pm2.47$ in affected side, $29.47\pm2.29$ in unaffected side, in S1 radiculopathy was $33.00\pm2.03$ in affected side, R30.18\pm2.21$ in unaffected side. It was statistically significant(p<0.01). H-reflex mean difference of S1 radiculopathy group was significantly prolonged as compared to the L5 and S1 radiculopathies(p<0.001). 4. In L2, 3 radiculopathy, abnormal spontaneous activities and motor unit action potentials were showed high sensitivity in upper lumber paraspinal, hip adductors, quadriceps and iliopsoas muscles. 5. In L4 radiculopathy, lower lumbar paraspinal, tibialis anterior, quadriceps muscles were showed high sensitivity. 6. In L5 radiculopathy, lower lumbar paraspinal, extensor hallucis longus, extensor digitorum longus, peroneus longus, extensor digitorum brevis, gluteus maximus, tensor fasciae latae muscles were showed high sensitivity. 7. In S1 radiculopathy, lower lumbar paraspinal, gluteus maximus, peroneus longus, soleus, abductor hallucis, hamstrings, extensor digitorum brevis, extensor hallucis lognus, gastrocnemius muscles were showed high sensitivity.

  • PDF