• Title/Summary/Keyword: TiOCl%24_2%24

Search Result 3, Processing Time 0.019 seconds

Hydrothermal Precipitation of PZT Powder (PZT분말의 수열합성에 관한 연구)

  • 이경희;이병하;대문정기;천하희흥지;강원호;박한수
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.397-403
    • /
    • 1987
  • Pb(Zr0.52Ti0.48)O3 powders were prepared by hydrothermal synthesis. Using soluble salts such as Pb(NO3)2, TiCl4 and ZrOCl2$.$8H2O and oxide such as PbO and TiO2 as starting materials, PZT powder was hydrothermally synthesized at the temperature range between 150$^{\circ}C$ and 200$^{\circ}C$. The result showed that reactivity by alkali was decreased in the sequence of Pb(NO3)2, TiCl4, ZrOCl2, PbO, TiO2 and ZrO2. Using the first three soluble salts, PZT powder was synthesiged at 150$^{\circ}C$ for 1hr. In PbO-TiCl4-ZrOCl2 system, PZT powder was synthesized at 150$^{\circ}C$ for 8rs. In Pb(NO3)2-TiO2-ZrOCl2 system, PZT powder was synthesized at 150$^{\circ}C$ for 16hrs, in PbO-TiO2-ZrOCl2 system, the powder was synthesized at 200$^{\circ}C$ for 8hrs.

  • PDF

Phase Transition of $TiO_2$ prepared by HPPLT (저온균일침전법에 의해 제조된 $TiO_2$의 상변화)

  • Hwang, Du-Seon;Lee, Nam-Hui;Lee, Gang;Kim, Seon-Jae
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.208-208
    • /
    • 2003
  • 저온균일침전법(HPPLT)으로 제조된 TiO$_2$나노분말은 10$0^{\circ}C$이하의 온도에서 rutile상을 얻을 수 있다. 또한, rutile에서 anatase로의 상변화는 합성시간, 가열속도, 반응온도 그리고 음이온 첨가에 의해 일어난다고 보고되어졌지만, 금속양이온들에 의한 상변화는 알려진 바가 없다. 따라서, 다양한 양이온을 첨가하여 저온균일침전법에서 TiO$_2$의 상변화가 어떻게 일어나는지를 조사하였다. 출발원료인 TIC1$_4$를 사용하여 가수분해하여 0.67M의 TiOCl$_2$을 얻었다. 얻어진 TiOCl$_2$ 수용액에 각각 0.01M의 금속염화물(ZrOCl$_2$, NiCl$_2$, CuCl$_2$, FeCl$_3$, AlCl$_3$ 그리고 NbCl$_{5}$)을 첨가한 후 반응기에 넣고 10$0^{\circ}C$에서 4시간동안 가열하였다 가열한 후 얻어진 침전물에 NaOH 수용액을 이용하여 PH 7-8로 중화한 후 증류수로 Cl$^{-}$이온이 제거될 때까지 충분히 세척하였다. 세척된 침전물을 105$^{\circ}C$에서 24h동안 건조하여 분말을 얻었고, rutile에서 anatase로의 상변화특성을 관찰하기 위하여 XRD, SEM, TEM, ICP 분석을 실시하였다.

  • PDF

Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex (근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향)

  • Moon, Ho-Jin;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.