• 제목/요약/키워드: Ti-Cr alloy

검색결과 190건 처리시간 0.025초

Ni-22Cr-18Fe-9Mo계 ODS 합금의 미세조직 및 고온인장 특성 평가 (Microstructural Evaluation and High Temperature Mechanical Properties of Ni-22Cr-18Fe-9Mo ODS Alloy)

  • 정석환;강석훈;한창희;김태규;김도향;장진성
    • 한국분말재료학회지
    • /
    • 제18권5호
    • /
    • pp.456-462
    • /
    • 2011
  • Yttrium oxide is one of the most thermo-dynamically stable materials, so that it is generally used as a dispersoid in many kinds of dispersion strengthed alloys. In this study, a nickel-base superalloy is strengthened by dispersion of yttrium oxide particles. Elemental powders with the composition of Ni-22Cr-18Fe-9Mo were mechanically alloyed(M.A.) with 0.6 wt% $Y_2O_3$. The MA powders were then HIP(hot isotactic press)ed and hot rolled. Most oxide particles in Ni-22Cr-18Fe-9Mo base ODS alloy were found to be Y-Ti-O type. The oxide particles were uniformly dispersed in the matrix and also on the grain boundaries. Tensile test results show that the yield strength and ultimate tensile strength of ODS alloy specimens were 1.2~1.7 times higher than those of the conventional $Hastelloy^{TM}$ X(R), which has the same chemical compositions with ODS alloy specimens except the oxide particles.

V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) 금속수소화물전극에 관한 연구 (A Study on the V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) Metal Hydride Electrodes)

  • 김정선;조원일;조병원;윤경석;김상주
    • 한국수소및신에너지학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-8
    • /
    • 1994
  • Lattice structure, hydrogen absorption characteristics, discharge capacity and cycle life of $V_{22}Ti_{16}Zr_{16}Ni_{39}X_7$(X= Cr, Co, Fe, Mn, Al) alloys were investigated. The matrix phases of these alloys were the C14 Laves phase. Chromium-containing alloy had a vanadium-rich phase in addition to the Laves phase. The chromium, maganese, or aluminum-containing alloys had lower hydrogen equilibrium pressure and larger hydrogen absorption content than the cobalt or iron-containing alloys. The discharge capacities of these alloys were 270~330mAh/g. The discharge capacity according to the alloying element X decreased in the order of Mn>Cr>Co, Al)Fe. The charge/discharge cycle lives of the chromium, cobalt or iron-containing alloys were longer than those of maganese or aluminum-containing alloys due to the lower vanadium dissolution rate.

  • PDF

베릴륨(Be)이 미 첨가된 치과도재소부용 Ni-Cr-Mo계 합금의 미세조직 및 기계적 성질 특성 (Microstructures and Mechanical Properties of Beryllium(Be)-free Ni-Cr-Mo based Alloys for Metal-Ceramic Crown)

  • 송경우;고은경;이정환;정종현;노학;한재익
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.321-329
    • /
    • 2006
  • The popularity of Ni-Cr-Mo based metal alloys for metal-ceramic crown have increased recently because of low price, superior yield strength and rigidity. the use of these alloys give them the potential advantage of thinner copping with the required rigidity for long span bridges. The purpose of this study was to assess the microstructures and mechanical properties of Ni-Cr-Mo-(Si,Al,Nb,Zr,Ti.Cu,Mm) based Alloys not containing beryllium(Be) related toxic effects. The abtained results indicated that as-cast these specimen alloys showed compositional and microstructural differences, and mechanical properties values of Ni69Cr20Mo5Si2Al4 alloy among these specimen alloys was found to be superior to those of commercial Ni-Cr based alloy using in market place today.

  • PDF

교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구 (A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions)

  • 이진우;차경석;한정숙
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.271-281
    • /
    • 2001
  • 치아에 부착된 bracket이 교정선을 따라 이동할때 필연적으로 bracket과 교정선, 결찰재 사이에 마찰력이 발생된다. 이에 저자는 동일한 bracket내에서 교정선의 종류, 결찰방법, 건조와 타액상태에 따른 마찰력 차이, 타액의 윤활제로서의 기능을 살펴보기 위해 본 연구를 시행하게 되었다. 본 실험에 사용된 bracket은 .18" ${\times}$ .025" slot의 상악 견치용 standard edgewise bracket(RMO. USA)이며, 교정선은 .016" , .016" ${\times}$ .022" 크기의 Cobalt-chromium(Elgiloy : RMO. USA), Nickel-titanium(Ni-Ti) (ORTHOLLOY : Goldstar Cable Co. KOREA), Beta- titanium(TMA : ORMCO Co., USA)의 2가지 형태의 3종을 이용하여 활주할 때의 마찰력을 만능시험기(Instron, M 1000 EC)를 사용하여 계측하여 다음과 같은 결론을 얻었다. 1. 각각의 동일조건하에서 교정선의 재질에 따른 마찰력은 Co-Cr, Ni-Ti, ${\beta}$-Ti순으로 증가하였다. 단, 타액상태에서 elastomeric으로 결찰한 .016" 군에서는 예외이다. 2. 각 조건하(건조/타액상태, .016" /.016" ${\times}$.022" ) 에서 결찰방법에 따른 마찰력은 elastomeric보다 stainless steel결찰에서 더 크게 나타났다(p<0.05). 3. 각각의 교정선과 결찰방법에서 타액 유무에 따른 마찰력은 stainless steel로 결찰한 .016" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 감소하나, stainless steel로 결찰한 .016" ${\times}$.022" Co-Cr, Ni-Ti, ${\beta}$-Ti는 타액상태에서 증가하였다(p<0.05). 4. 각 조건하(건조/타액상태, elastomeric/stainless steel 결찰) .016" 과 .016" ${\times}$.022" 교정선 사이의 마찰력은 .016" ${\times}$.022" 교정선에서 증가하였다(p<0.05).

  • PDF

자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가 (Evaluation of image quality for metal artifact using protocol parameters in the MRI)

  • 이수현;김도경;김요한;염혜정;이헌준;임주연;최우전;김동현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.582-585
    • /
    • 2015
  • 고령화 사회로 인한 관절 질환 환자의 증가로 TKRA(Total Knee Replacement Arthroplasty)가 증가하고 있다. 이에 따라 TKRA에 사용되는 인공관절에 의해 MRI영상에서 금속인공물이 발생하게 되는데 이는 진단에 영향을 미치게 된다. 그러므로 본 논문에서는 Co-Cr, Ni-Ti 소재의 인공관절과 시퀀스 변화를 주어 영상에서의 영향을 최소화시켜 진단의 효과를 높이고자 한다. 1.5T AVANTO장비와 플라스틱 통, 각각의 인공관절(Normal, Co-Cr, Ni-Ti)을 사용하였으며 종이컵 안에 인공관절을 고정시킨 후 원통 모양의 플라스틱 통 안에 넣어 신호강도를 측정하였다. 균일하고 강한 신호강도를 획득하기 위하여 플라스틱 통은 물로 채웠다. 시퀀스는 T1 TSE, T2 TSE, PD TSE로 변화하면서 실험하였고 Axial영상을 획득하였다. 신호강도는 동일한 크기의 관심영역을 설정하여 최대값, 최소값을 제외한 후 평균을 구해 SNR, CNR을 측정하고 Image J를 이용해 PSNR을 측정하였다. 결과적으로 PD TSE가 T1 TSE, T2 TSE에 비하여 SNR과 CNR 값이 크게 나타나왔고 Co-Cr이 Ni-Ti에 비하여 PSNR의 수치도 크게 나타나고 Normal의 SNR 값과 유사하게 나타난 것으로 보아 PD TSE의 시퀀스와 Co-Cr의 합금을 사용하는 것이 진단 및 판독을 하는데 있어서 유용할 것으로 사료된다.

  • PDF

Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구 (MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY)

  • 정희찬;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

Eco-friendly Fabrication Process of Al-Ti-C Grain Refiner

  • Cho, Hoon;Kim, Bong-Hwan
    • 한국주조공학회지
    • /
    • 제30권4호
    • /
    • pp.147-150
    • /
    • 2010
  • 알루미늄 합금의 미세조직 개량을 위한 목적으로 사용되는 Al-Ti-B 합금계의 미세화제는 재활용 과정에서 붕소(B)의 농축(Agglomeration) 문제 및 Zr, Si, Cr 등을 함유하는 합금에서 미세화 효과가 급격히 감소하는 Poisoning effect 등이 지적되어 왔다. 최근에는 이를 대체할 수 있는 Al-Ti-C 합금계의 미세화제에 대한 연구가 활발한데 이는 TiC가 용탕 내에서 ${\alpha}$-Al의 핵생성처로 직접 작용하는 점에 착안한 것이다. 한편, 이들 Al-Ti-B, Al-Ti-C 계의 미세화제는 그 제조공정에서 $K_2TiF_6$를 이용함에 따라 불소함유 유해가스를 배출하여 환경 문제를 야기하고, 이를 포집/정화하기 위한 추가설비를 요구하게 된다. 따라서 대기 환경 오염 및 경제성 측면에서 유리한 미세화제의 친환경 제조기술에 대한 개발이 필요한 시점이다. 본 연구에서는 $K_2TiF_6$를 사용하지 않고 용탕 내의 자발적 반응을 이용하여 환경 및 경제적 측면에서 유리한 Al-Ti-C 미세화제를 개발하고자 하였다. A3003 합금을 대상소재로 하여 개발된 Al-Ti-C 미세화제와 상용 Al-Ti-B 미세화제의 미세화 도달시간 및 fading 발생 등을 비교하였다. 본 연구를 통하여 개발된 Al-8.6Ti-0.025C 미세화제는 상용 Al-Ti-B 미세화제 보다 적은 첨가량에도 유사한 미세화 성능을 나타내었으며 용탕 유지시간 100분까지도 fading이 발생하지 않는 것을 확인하였다.

이온빔 보조 증착법에 의한 TiN 박막도포가 니켈-크롬-베릴륨 합금의 표면 성상에 미치는 영향에 관한 연구 (A STUDY OF ION BEAM ASSISTED DEPOSITION(IBAD) OF TiN ON Ni-Cr Be ALLOY FOR SURFACE CHARACTERISTIC)

  • 최수영;이선형;장익태;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.212-234
    • /
    • 1999
  • Dental restorative materials must have the physical properties to withstand wear and corrosion. Base metal alloys possess better mechanical properties and lower price than the gold alloys. For these reasons such alloys have largely replaced the precious metal alloys. One aspect to con-sider is the release of metal substances to oral environment. The release of elements from dental alloys is a continuing concern because the elements may have the potentially harmful biological effects on local tissues. The purpose of this study was to minimize metal release on the nonprecious metal surfaces by ion beam assisted deposition(IBAD) of titanium nitride (TiN) Ni-Cr-Be alloys with and without TiN coatings were secured in an wear test machine opposing ruby ball to determine their relative resistance to wear with loom, 200m, 300m and 400m sliding distance. And the corrosion behavior of the Ni-Cr-Be alloys with and without TiN coatings and 3 dental noble alloys have been studied. Potentiodynamic curves were used to analyse the corrosion characteristics of the alloys. The measurement of the released Ni and Cr ions was conducted by analysis of the electrolyte solution with atomic absorption spectroscopy. The results were as follows : 1. The critical sliding distance that wore down TiN coatings of $2.5{\mu}m$ thickness in this study condition was 300m. 2. Ion beam assisted deposition of TiN showed a good surface modification with respect to the properties of wear and corrosion resistance. 3. X-ray diffraction showed that the strongest peak of TiN is TiN(111) in the coatings. 4. The release of Ni and Cr ions from alloys measured by means of atomic absorption spectroscopy was reduced by ion beam assisted deposition of TiN.

  • PDF

비귀금속 산화물이 치과용 합금과 도재의 화학적 결합에 미치는 영향 (Effects of Nonprecious Metallic Oxide on the Chemical Bonding Between Dental Alloy and Porcelain)

  • 김광남;조성암
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.317-325
    • /
    • 1987
  • A study on the shear bonding strength between dental alloy and porcelain according to various kidns of sputtered metallic thin films was established by Ingtron universal testing machine, and the change of the elemental weight % at the surface of dental alloy was studied by E.D.S. The kind of metallic thin films were Al, Ni, In, Cr. Ti and Sn with $0.3{\mu}m$ thickness. The dental alloys were Verabond made by Aalba Dent. Co. and Degudent H manufactured by Degussa Co. The control groups were Verabond and Degudent H. The obtained results were as follows; 1. The shear bonding strength of Al plated sample was the strongest of all. 2. The shear bonding strength of Ni plated sample was stronger than that of Degudent H, Sn plated samples. 3. The shear bonding strength of Verabond was weaker than that of Al, Ni, In, Cr, plated samples. 4. After degassing, it is more weight % of Ni at the alloy surface of the Ni sputtered specimen than the Sn sputtered sample.

  • PDF

$AB_2$계 수소저장합금의 전극특성에 미치는 Cr, La 첨가 효과 및 표면 불화처리 효과 (Electrode characteristics of $AB_2$ type hydrogen storage alloy modified by Cr, La addition and fluorination)

  • 장일;이병호;조원일;장호;조병원;윤경석
    • 전기화학회지
    • /
    • 제1권1호
    • /
    • pp.45-51
    • /
    • 1998
  • Ni-MH 전지의 음극으로 쓰이는 수소저장합금(MH)의 한 종류인 $AB_2$계 합금은 수소저장량이 큰 장점이 있으나 초기활성화나 싸이클 수명 및 자기방전 특성이 나쁜 단점이 있다. 본 연구에서는 Zr-Ti-V-Mn-Ni계 합금에 비화학양론적으로 Cr을 소량 첨가했을 때와 La을 첨가하여 불화처리 했을 때의 초기활성화, 싸이클 수명 및 자기방전에 미치는 영향을 조사하였다 EPMA 및 SEM을 이용하여 합금의 표면을 분석하였으며 XRD 분석으로 결정구조를 관찰하였다. 또한 합금으로 전극을 제조하여 정전류 시험법, 임피던스법과 전위주사법 등에 의해 전극특성을 조사하였다. Cr이 첨가될수록 전극표면에 안정한 산화막이 형성되어 V등의 전해질로의 용해를 막아주어 충, 방전에 따른 수명특성 및 자기방전 특성을 향상시키지만 초기 전하이동 반응이 저해되어 초기활성화 특성이 악화되었다. La을 첨가 후 불화처리하면 표면에 반응성이 좋은 입자를 형성하여 전극의 초기 활성화가 크게 향상되었다.