• 제목/요약/키워드: Thyroid cells

검색결과 238건 처리시간 0.02초

갑상선 여포상 선종과 암종의 감별진단에서 $p27^{KIP1}$, MIB-1, bcl-2, p53 발현의 유용성에 대한 연구 (The Significance of $p27^{KIP1}$, MIB-1, bcl-2 and p53 Expression in the Differential Diagnosis of Follicular Adenoma and Carcinoma of the Thyroid Gland)

  • 강미선;윤혜경;김상효;윤기영;이충한;최경현;허방;노미숙;홍숙희
    • 대한두경부종양학회지
    • /
    • 제17권2호
    • /
    • pp.139-147
    • /
    • 2001
  • Objectives: The most important differential point of follicular carcinoma from adenoma is capsular invasion or angioinvasion of follicular cells. Serial sections for examination of levels of tumor margins are necessary to watch the invasion. However, the interpretation of capsular invasion or angioinvasion is sometimes not feasible on the routine staining of tumor tissue. The aim of this study is to evaluate the clinical significance of expressions of $p27^{KIP1}$, MIB-1, bcl-2 and p53 in differential diagnosis of follicular adenoma and carcinoma. Materials and Methods: 16 cases of follicular carcinoma and 26 cases of follicular adenoma were entered on study of immunohistochemical stains for $p27^{KIP1}$, MIB-1, bcl-2 and p53. In carcinoma cases, correlation between the above markers, patient's age, tumor size, infiltration pattern and metastasis was studied. Results: $p27^{KIP1}$ labelling index (LI) of follicular carcinoma and adenoma was $4.89{\pm}6.92$ and $14.52{\pm}9.17$, respectively, but there was no significant difference between adenoma and carcinoma (p=0.2560). MIB-1 LI of carcinoma and adenoma was $4.11{\pm}3.89$ and $0.80{\pm}0.75$, respectively, and MIB-1 LI was significantly higher in carcinoma (p=0.0000). bcl-2 expression was seen in 2(12.5%) of 16 carcinoma cases and 130(50.0%) of 26 adenoma cases, and bcl-2 expression rate was higher in adenoma than in carcinoma(p=0.014). In one adenoma and one carcinoma case, p53 expression was noted. In follicular adenoma with atypia compared to adenoma without atypia, lower $p27^{KIP1}$ LI, higher MIB-1 LI and lower bcl-2 expression rate were seen. In follicular carcinoma, MIB-1 LI was significantly higher in invasive carcinoma(p=0.045) and was relatively increased in tumors larger than 3.0cm, showing angioinvasion and distant metastasis. But $p27^{KIP1}$ LI was higher in cases over 40 years old(p=0.008) and with conspicuous capsular invasion. There were no positive correlations between expressions of MIB-1, bcl-2 and p53. Conclusion: MIB-1 labelling index and bcl-2 expression could be helpful for differential diagnosis of follicular adenoma and carcinoma, but p53 showed very low expression rate and no significance in differential diagnosis. $p27^{KIP1}$ labelling index reveals decreasing tendency in carcinoma compared with adenoma, MIB-1 LI was considered as a poor prognostic marker in follicular carcinoma, but $p27^{KIP1}$ LI was higher in carcinoma cases over 40 years old with showing conspicuous capsular invasion. Further study for the significance of $p27^{KIP1}$ labelling index in follicular neoplasms is necessary to evaluate diagnostic value of follicular carcinoma.

  • PDF

폐조직구증식증의 임상적 특징 (Clinical Characteristics of Pulmonary Histiocytosis X)

  • 황용일;박근민;임채준;유철규;이춘택;김영환;한성구;심영수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제51권4호
    • /
    • pp.346-353
    • /
    • 2001
  • 연구배경 : 조직구증식증(Histiocytosis X)는 Langerhans 세포의 단클론성 증식과 이로 인한 인체 장기로의 침윤을 특징으로하는 질환이다. 조직구증식증이 발병할 수 있는 장기로는 폐, 골격계, 피부, 뇌하수체, 간, 임파선, 갑상선 등이 있다. 폐 조직구증식중의 임상상과 예후에 대하여 알아보고 기존의 연구들과 비교해 보고자 하였다. 연구방법 : 1990년 1월부터 1998년 12월까지 서울대학교병원 내과에 입원하여 병리학적으로 폐조직구증식증을 진단 받은 14명을 대상으로 후향적 연구를 시행하였다. 환자들의 치료력을 확인하고 추적 관찰 기간 동안의 환자의 증상, 폐기능 검사 소견, 방사선 검사 소견으로 치료에 대한 반응여부를 조사하였다. 결 과 : 대상환자는 14명이었고 남자가 12명 여자가 2명이었다. 흡연은 8명(57%)에서만 하였고 폐 외 장기로의 침범은 5명에서 있었다. 8명의 환자에서 약물치료가 시행 되었으며 사망한 환자는 없었으며 1명의 환자에서만 증상의 악화를 경험하였다. 결 론 : 본 연구의 폐조직구증식증은 기존의 외국의 보고들과 비교하여 남성에서 많이 발병하고 흡연자의 비율이 비교적 낮으며 비교적 양호한 경과를 보이는 점에서 차이를 발견할 수 있었다.

  • PDF

$^{131}I$의 체외 방사선조사에 의한 염색체이상 (Chromosomal Aberrations Induced by in Vitro Irradiation of $^{131}I$)

  • 김은실;김명선;서두선;정내인;노승익;이재용;김종순;한승수;김희근;강덕원;송명재
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.133-140
    • /
    • 1994
  • 연구배경 : 방사선치료시, 작업장에서 또는 방사선사고시의 방사선에 피폭되었을 때 피폭선량을 정확하게, 가능한한 빨리 추정해 내고 적절한 의료대책을 세우기 위해서는 선량-반응관계의 표준곡선이 요구되어지는데 생물학적 선량측정방법으로는 피폭자의 말초혈액을 배양하여 관찰한 림프구에서 얻은 염색체이상의 빈도로써 피폭선량을 추정하는 방법이 많이 이용되고 있다. 이에 저자등은 갑상선기능항진증 및 갑상선암 환자에서 치료제로 투여되는 $^{131}I$을 체외에서 조사시켜 선량-반응관계의 표준곡선을 얻고 피폭시의 치료 및 추적관찰의 근거를 마련하고자 하였다. 방법 : 최근 3년간 0.01 Gy 이상의 방사선조사를 받은 적이 없는 건강한 사람의 말초혈액을 채취하여 $^{131}I$을 0.05, 0.10, 0.15, 0.20, 0.30, 0.50Gy의 저선량에서 0.75, 1.00, 2.00, 3.00, 4.00, 5.00, 6.00Gy의 고선량이 되도록 체외에서 조사시켜 PHA를 첨가하고 림프구를 배양 관찰하였다. 실험동안에는 빛을 차단하고 $37^{\circ}C$의 체온과 같은 조건을 유지시켰고, 배양된 세포는 현미경 검경하여 dicentric 염색체, ring 염색체 및 acentric fragment 쌍등 불안정 염색체이상의 빈도를 관찰하였다. 결과 방사선조사를 받지 않은 세포에서는 염색체이 상을 관찰할 수 없었다. 관찰한 세포중 dicentric 염색체와 ring 염색체의 빈도로써 나타내는 Ydr값은 0.05, 0.10, 0.15, 0.20, 0.30, 0.50Gy에서 각각 0.003, 0.004, 0.004, 0.005, 0.005, 0.008이었고, 0.75, 1.00, 2.00, 3.00, 4.00, 5.00, 6.00Gy에서는 각각 0.046, 0.057, 0.143, 0.302, 0.389, 0.842, 1.720으로써 선량이 증가함에 따라 증가하였으나, 이상염색체를 가진 림프구내에서의 이상염색체의 빈도인 Qdr값은 0.75Gy이하에서는 모두 1이었고, 1.00, 2.00, 3.00, 4.00, 5.00, 6.00Gy에서는 각각 1.2, 1, 1.04, 1.09, 1.33, 2.53으로써 저선량에서는 차이가 없었다. 위와 같은 선량-반응관계를 비선형 회귀분석 한 결과 방사선량(D)과 염색체이상 빈도(Ydr)와의 관계는 Y=0.064351 $D^2$-0.13143 D+0.045684로 나타나 선량에 따른 염색체 이상의 빈도는 위와 같은 이차함수식으로 증가함을 알 수 있었다. 결론 : $^{131}I$의 방사선량이 증가함에 따라 이상염색체의 빈도는 이차함수식으로 증가하는 표준선량반응곡선을 얻었으므로 피폭선량을 추정하는 근거를 마련하였다.

  • PDF

The Study of Spontaneous Developmental Abnormalities and Toxicology of Benomyl and Its Metabolite on Salamander, Hynobius leechii.

  • 박용욱
    • 한국환경생물학회:학술대회논문집
    • /
    • 한국환경생물학회 2005년도 추계학술대회 초록집
    • /
    • pp.38-45
    • /
    • 2005
  • The egg bags of Korean salamander(Hynobius leechii) were collected from farmlands in Gyeongsangnam-do area. The assumed breeding time, numerical variation of embryos in each egg bag, mortality and the rates of abnormalities were investigated. The toxicity of benomyl, the metabolite carbendazim and BIC which were frequently spread in agricultural area and caused spontaneous embryonic malformation was investigated. The assumed breeding time between the end of February and the end of March has the difference about a month because of a habitat and it takes about 2 or 3 weeks from laying eggs to hatching. The length of each egg bag and the number of embryos were very varied in each area. It is due to geographical variation. Among egg bags in total study area, only 406 of egg bags(17.70% of total egg bags) developed all of embryos to normal larvae, and 78.49% of total embryos were normally developed. The patterns of spontaneous embryonic malformation were 26 species from A to Z and the abnormal patterns in individual were 8 species and above. the geographical differences about the abnormal pattern were identified and 11 habitats categorized 4 groups. The most frequent abnormality in Gyeongsangnam-do area is the dysplasia of external gill. The caudal dysplasia, abdominal blister and dysplasia of fin were also frequently observed. Individuals showing severe external defect were histologically studied and they showed retinal hypo-pigmentation, thyroid carcinoma, somatic muscular dysplasia, degeneration of cephalic neuron and various organ dysplasia. Benomyl and carbendazim were treated by 10pM$^{\sim}$10uM and BIC was treated by 1$^{\sim}$40ppm to know the effect of toxicity about toxic substance of salamander. After benomyl was treated, a survival rate was sharply dropped from 2 to 8 days. $LC_{100}$ identified in $1{\mu}M$, $LC_{50}$ identified between 100nM and $1{\mu}M$. $EC_{50}$ was assumed between 10nM and 100nM. The prevalent external malformation was abdomen swelled abnormally and histo-pathological effects were abdomen, neural tube and lens hernia. This suggests that benomyl is the toxicitic substance which inhibits the development of digestive system and nervous system. The result of treated carbendazim was similar to that of the treated benomyl. The survival rate is sharply dropped between 2 and 6 days. $LC_{100}$ was identified $1{\mu}M$ and $LC_{50}$ was identified between 10nM and 100nM. This shows that cabendazim has stronger lethal toxicity than benomyl. Ventral blister, eye dysplasia and cephalic dysplasia in the individual of external malformation mean that cabendazim affected nervous system much more than benomyl. Because the toxicity of BIC affected less in the beginning but affected more in the near hatching period, the period causing toxicity is somewhat different. $LC_{100}$ identified near 40ppm and $LC_{50}$ identified near 25ppm. The external defect shows mainly ventral blister and histo-pathological results show intestinal deformities. This result suggests the BIC inhibited strongly the development of digestive system. These abnormal developments may be caused by antimitotic action, inhibition of tubulin complex, destruction of microtubule, inhibitions of neurulation and closing of neural fold, and by the inhibition of movement of neural crest cells of benomyl. These abnormal developments may be caused by the rupture of epithelium, the loss of microtubule, the reduction of spindle size, the inhibition of spindle assembly formation, the destruction of spindle poles of carbendazim. These abnormal developments may be caused cytotoxicity by inhibition of the synthesis of a number of macromolecules and similar reaction the inhibition of benomyl.

  • PDF

원발성 유방암에서 Sodium Iodide Symporter의 발현과 $^{99m}Tc-MIBI$ 유방스캔의 관계 (Relationship between the Expression of Sodium Iodide Symporter and the Findings of $^{99m}Tc-MIBI$ Scintimammography in the Primary Breast Cancer)

  • 석주원;김성장;곽희숙;이창훈;김인주;김용기;배영태;김동수
    • 대한핵의학회지
    • /
    • 제36권6호
    • /
    • pp.325-332
    • /
    • 2002
  • 목적: hNIS는 갑상선 조직 외에 다른 조직들에서도 발현된다고 알려져 있다. 유방암 세포는 그런 조직들 중에 하나이며, 그에 의한 유방암의 방사성옥소치료의 가능성이 제시되고 있다. 본 연구에서는 유방암 조직에서 hNIS의 발현정도를 알아보고, $^{99m}Tc-MIBI$ 유방스캔과 hNIS의 발현 정도와의 관계를 조사하여 보았다. 대상 및 방법: 본 연구에서는 유방암으로 수술을 시행했던 56명의 환자를 대상으로 하였다. hNIS의 발현은 면역조직화학염색에 의해서 평가되었으며, 그 결과를 $^{99m}Tc-MIBI$ 유방스캔의 판정 결과와 비교하였다. 결과: 전체 56명의 환자에서 hNIS의 발현율은 41.1%였다. 병리학적 진단에 의해 침윤성관상피암종이었던 49명에서의 발현율은 42.9%, 관상피내암종이었던 7명에서의 발현율은 28.6%였다. $^{99m}Tc-MIBI$ 유방스캔에서 국소섭취 소견이 관찰되었던 41명에서의 hNIS의 발현율은 31.7%였다. 비정상적인 섭취 소견이 관찰되지 않았던 15명의 환자에서의 hNIS의 발현율이 의미있게 높게 관찰되었다(66.7%, p>0.05). 결론: 유방암 환자에서의 hNIS의 발현율은 그다지 높지 않았다. $^{99m}Tc-MIBI$ 유방스캔에서 섭취증가 소견이 없을 때 hNIS의 발현율이 더 높았다.

흑색종에서의 I-131표지 혈관내피세포성장인자 수용체2항체를 이용한 방사면역치료 평가 (Evaluation of the Radioimmunotherapy Using I-131 labeled Vascular Endothelial Growth Factor Receptor2 Antibody in Melanoma Xenograft Murine Model)

  • 김은미;정환정;박은혜;정수진;이창문;장규윤;김동욱;임석태;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권4호
    • /
    • pp.307-313
    • /
    • 2008
  • 목적: 혈관내피성장인자(VEGF)와 그 수용체는 종양의 성장과 전이에 매우 중요한 역할을 한다 3개의 수용체가 알려져 있는데 그 중에서도 VEGFR2 (Flk-1/KDR)가 종양 angiogenesis에 매우 밀접하게 관련한 것으로 알려져 있다. 본 연구에서는 마우스 Flk-1 항체로 알려진 DC101에 I-131을 표지하여 매우 공격적인 종양으로 알려진 흑색 종의 치료 정도를 확인해 보고자 하였다. 방법: 하이브리도마 세포에서 Flk-1 항체인 DC101을 분리하여 western blot, ELISA, maldi-tof 방법을 이용하여 순도를 확인하고 항체 에 chloramin T를 이용하여 I-131을 표지하였다. 누드마우스에 B16F10세포를 주사하여 흑색종 모델을 만들고 평균 $200-250\;mm^3$으로 키워 $^{131}I$-DC101을 주사하여 영상과 시간별 장기섭취율(%ID/g)을 비교하고, 종양내 Flk-1 발현을 확인하기 위하여 면역염색 등을 시행하였다. 흑색종 동물모델을 5개 군으로 나누어 각각 치료를 시행하였다. 1군은 PBS만을, 2군은 $^{131}I$-DC101 $50\;{\mu}g(200\;{\mu}Ci)$을, 3군은 DC101 $50\;{\mu}g$을, 4군은 $^{131}I$-DC101 $30\;{\mu}g(200\;{\mu}Ci)$을, 5군은 $^{131}I$-DC101 $15\;{\mu}g(200\;{\mu}Ci)$을 각각 매 3일 ${\sim}$ 4일마다 주사하고 전체 5회를 주사하였고 종양볼륨을 측정하였다. 결과: $^{131}I$-DC101을 흑색종 모델에 정맥주사하고 78시간까지 영상을 얻은 결과 시간에 따라 종양섭취가 증가 하는 영상을 보였다. 시간대별 장기섭취를 정확히 확인하기 위하여 1시간, 6시간, 24시간, 48시간, 72시간 장기섭취율을 비교한 결과 시간에 따라 혈액내 방사능치가 서서히 감소하였고 다른 장기의 섭취도 시간에 따라 감소하였고 종양의 섭취는 48시간까지 증가하였다가 그 이후는 감소하였다. 흑색종 동물모델에 $^{131}I$-DC101 치료를 시행한 결과 3번째 주사까지는 각군간의 유의한 차이를 보이지 않다가 4번째 주사를 시행한 때부터 1군과 2군, 또는 1군과 4군간의 유의한 차이를 보이기 시작했다. 또한 5번째 주사 이후에는 5군에서도 유의한 차이를 보여 I-131 에 의한 효과가 뚜렷해짐을 확인하였다. 결론 마우스 Flk-1 항체로 알려진 DC101을 흑색종 모델에 정맥내 주사하였을 때, 종양성장억제 효과를 보이지 않는 항체양에서도 I-131을 표지하여 치료를 시행했을 경우에는 효율적인 종양성장억제 효과를 보였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF