• Title/Summary/Keyword: Thyroid Ultrasound

Search Result 74, Processing Time 0.022 seconds

Texture analysis of Thyroid Nodules in Ultrasound Image for Computer Aided Diagnostic system (컴퓨터 보조진단을 위한 초음파 영상에서 갑상선 결절의 텍스쳐 분석)

  • Park, Byung eun;Jang, Won Seuk;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • According to living environment, the number of deaths due to thyroid diseases increased. In this paper, we proposed an algorithm for recognizing a thyroid detection using texture analysis based on shape, gray level co-occurrence matrix and gray level run length matrix. First of all, we segmented the region of interest (ROI) using active contour model algorithm. Then, we applied a total of 18 features (5 first order descriptors, 10 Gray level co-occurrence matrix features(GLCM), 2 Gray level run length matrix features and shape feature) to each thyroid region of interest. The extracted features are used as statistical analysis. Our results show that first order statistics (Skewness, Entropy, Energy, Smoothness), GLCM (Correlation, Contrast, Energy, Entropy, Difference variance, Difference Entropy, Homogeneity, Maximum Probability, Sum average, Sum entropy), GLRLM features and shape feature helped to distinguish thyroid benign and malignant. This algorithm will be helpful to diagnose of thyroid nodule on ultrasound images.

Ultrasound Score to Select Subcentimeter-sized Thyroid Nodules Requiring Ultrasound-guided Fine Needle Aspiration Biopsy in Eastern China

  • Cheng, Pu;Chen, En-Dong;Zheng, Hua-Min;He, Qiu-Xiang;Li, Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4689-4692
    • /
    • 2013
  • Ultrasound-guided fine needle aspiration biopsy (FNAB) is a costly diagnostic item with a low yield in identifying the tiny proportion of nodules that actually represent malignant disease. Our aim through this study was to obtain an ultrasound (US) score for selecting subcentimeter-sized thyroid nodules requiring FNAB in eastern China. Some 248 patients for a total of 270 thyroid nodules less than 1 cm in diameter underwent FNAB and subsequent surgery from January 2006 to March 2012 at our hospital. The clinicopathological and US data from all the nodules were analyzed retrospectively. An US score was developed on the basis of independent predictive factors for malignancy. Irregular shape, hypoechogenicity, no well-defined margin, presence of calcifications and ratio between antero-posterior and transversal diameters (AP/TR) ${\geq}1$ were independent predictive factors for malignancy on logistic regression analysis. US score were statistically significant, with ${\leq}2$ favoring benignancy with an 80.3% sensitivity and a 72.7% specificity. US score is useful for differentiating between malignant and benign subcentimeter-sized thyroid nodules. We suggest FNAB for nodules when the US score is higher than 2.

Efficacy of Lauromacrogol Injection for Ablation of Benign Predominantly Cystic Thyroid Nodules and Related Factors: A Prospective Study

  • Yi Jie Dong;Zhen Hua Liu;Jian Qiao Zhou;Wei Wei Zhan
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.479-487
    • /
    • 2022
  • Objective: To prospectively evaluate the efficacy of lauromacrogol injection for ablation (LIA) of benign predominantly cystic thyroid nodules and its related factors. Materials and Methods: A total of 142 benign predominantly cystic thyroid nodules (median volume, 12.5 mL; range, 0.4-156 mL) in 137 patients (male:female sex ratio, 36:101; mean age ± standard deviation [SD], 49 ± 13 years) were treated with LIA after being confirmed as benign via cytology. The volume reduction rate (VRR) of the nodules and cosmetic score were evaluated during follow-up at 1, 3, and 6 months after treatment and every 6 months thereafter. A VRR of ≥ 50% at the 12-month follow-up was considered to indicate effective treatment. The associations between the clinical factors and nodular ultrasound features, including the initial nodule volume, proportion of solid components, vascularity grade and ineffective treatment (VRR of < 50% at the 12-month follow-up), and regrowth were analyzed. Results: All patients completed follow-up for at least 12 months. The average ± SD follow-up period was 32 ± 11 months (range, 12-54 months). The effective treatment rate was 73.2% (104/142), while the regrowth rate was 12.0% (17/142) at the last follow-up. Grade 2-3 intranodular vascularity in the solid components of the nodules was the only independent factor associated with ineffective treatment, with an odds ratio (reference category, grade 0-1) of 3.054 (95% confidence interval, 1.148-8.127) (p = 0.025). Conclusion: LIA is an effective treatment for predominantly cystic thyroid nodules. Grade 2-3 intranodular vascularity in the solid components of nodules is the only independent risk factor for ineffective LIA.

The Clinical Association of Thyroid Lesions in Patients with Globus Pharyngeus (인후두부 이상감을 호소하는 환자와 갑상선 병변과의 임상적 연관성)

  • Park Kyoung-Ho;Park Young-Hak;Hwang Sung-Jae;Kang Min-Gon;Park Hong-Jin;Kim Min-Sik;Cho Seung-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.10 no.2
    • /
    • pp.43-48
    • /
    • 2004
  • Background and Objectives : Globus pharyngeus is the feeling of a lump or foreign body in the throat. Otolaryngologists are often confronted with this condition, and some author reported that it represents 3 percent of all new clinic referral. The purpose of this study is to estimate the incidence of impalpable thyroid lesion in patients with globes pharyngeus and investigate possible association between globus pharyngeus and thyroid lesions. Material and Method : 146 patients with globus pharyngeus and 30 controls were prospectively examined by high resolution ultrasound. Results: Thyroid abnormalities were present in $75/146(51\%)$ patients with globus pharyngeus and in $7/30(23\%)$ controls. Of the patients with globus, 55 patients had a nodule or nodules, 11 patients had a cyst or cysts, 9 patients had diffuse abnormalities. Solitary nodule ranged from 4mm to 20mm. Conclusion : Impalpable, ultrasound detectable thyroid abnormailities are significantly more common in patients with globus pharyngeus than in controls. The thyroid abnormalities may be the cause of globus symptoms in some patients, and high resolution ultrasound is an important modality in patients presenting with globus.

  • PDF

The Role of Ultrasound Guided Core Needle Biopsy in Thyroid Nodule (갑상선 결절에서 초음파 유도하 중심생검의 역할)

  • Ryu, Yoon-Jong;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • Fine needle aspiration cytology(FNAC) holds a main role in assessing thyroid nodules. But nonnegligible rate of thyroid cytology is reported as uncertain, indeterminate or inadequate for diagnosis. Recently, the microhistologic evaluation by core needle biopsy(CNB) under ultrasound sonographical guidance has been reported to show high accuracy for the diagnose of thyroid nodules. Aim of this review was to furnish the state of the art of this topic by summarizing previous published data about indication, diagnostic performance, and complication of CNB in thyroid lesions compared with FNAC

  • PDF

Diagnostic Value of Ultrasound-Guided Fine Needle Aspiration Biopsy in Malignant Thyroid Nodules: Utility for Micronodules

  • Unal, Betul;Sezer, Cem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8613-8616
    • /
    • 2014
  • Background: The diagnostic approach to thyroid nodules involves ultrasound-guided fine needle aspiration biopsy (US-FNAB). We especially aimed to evaluate the contribution and the place of US-FNAB in preoperative evaluation of the malignant cases and draw attention to discordant cases diagnosed with papillary thyroid microcarcinoma (PTMC). Materials and Methods: A total of 276 cases were retrospectively reviewed who were subsequently diagnosed with a malignancy and who underwent US-FNAB. Results: Some 45 were found to have previously undergone the US-FNAB procedure. Of the patients in whom the surgical specimen was diagnosed with a malignancy, 21 (46.7%) were diagnosed as malignant or suspicious for malignancy, and 24 (53.3%) were concluded as benign or insufficient for diagnosis. Patients with the diagnosis of PTMC outnumbering the others was a striking finding (11 cases, 24%). Conclusions: We suggest performing repeat aspiration biopsy considering sampling errors in cases where inconsistency exists between clinical findings and cytological results in thyroid nodules smaller than 10 mm in diameter and with suspicious findings on ultrasonography.

A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule (비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치)

  • Choi Nak-Seon;Yoon Jung-Han;JaeGal Young-Jong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF