• 제목/요약/키워드: Thyroid Dose

검색결과 303건 처리시간 0.032초

갑상선암 환자에서 전절제술 후 I-131 치료에서 미만성 간침착 정도의 분석 (Analysis of Diffuse Hepatic Visualization after Iodine-131 Treatment in Patients with Thyroid Carcinoma)

  • 정진형;배금석;강성준
    • 대한두경부종양학회지
    • /
    • 제16권2호
    • /
    • pp.206-211
    • /
    • 2000
  • Objectives: Any uptake of I-131 after total thyroidectomy means the remant thyroid tissue or distant metastasis of the thyroid cancer. However diffuse hepatic uptake of I-131 without abnormal uptake was showen in many cases on I-131 whole body scan. The aim of this study was to classify the liver uptake after I-131 scan and to evaluate the analysis of this finding. Materials and Methods: Between 1982 and 1998, 104 patients(l4 males, 90 females) with normal liver function underwent I-131 scan after total thyroidectomy. Prospectively we reviewed the films of the whole body scan and analysed the correlations between results of radioiodine uptake, pathologic diagnosis, prognostic factors, lymphatic metastasis, and thyroid function test. Result: Diffuse hepatic uptake was found in 44 of 104(42%) patients. 10 of 39(26%) patients on I-131 100mCi, and 34 of 63(54%) on I-131 150mCi showed hepatic uptake. 52 of 104(50%) patients was locally invasive thyroid cancer. The rate of the hepatic uptake was no significant differences with the thyroid hormone levels(T3, Free T4) and thyroglobulin between uptake group and non-uptake group. Conclusion: The rate of I-131 uptake was high in high-dose radioiodine treatment group. However, we can not find any correlation among the thyroid functions, the extent of metastasis or the extent of local invasion. We need further study to find out the causes of the hepatic uptake of I-131 after total thyroidectomy, besides liver metabolism of I-131 attached thyroid hormones.

  • PDF

갑상선 암의 판정에 대한 술전 초음파의 의의 (Diagnostic Value of Preoperative Ultrasonographic Evaluation on Thyroid Cancer)

  • 윤길훈;류기선;정진영;조재현;김명욱;소의영
    • 대한두경부종양학회지
    • /
    • 제15권1호
    • /
    • pp.66-69
    • /
    • 1999
  • Background and Objectives: It is critical to distinguish benign from malignant thyroid nodule and to select a patient for surgery. Even though the U/S study dose not make great contribution to diagnose a malignant thyroid nodule, it is widely used in the evaluation of anatomic feature of thyroid. The authors tried to estimate the efficacy of the U/S study in preoperative diagnosis of malignant thyroid nodule. Materials and Method: At the department of General Surgery of Ajou University, 75 patients who were operated after diagnosis with thyroid nodule by U/S study between July 1996 to June 1997 were retrospectively analyzed. By comparing the U/S impression that implies malignant thyroid nodule to FNAC and post-operative pathologic results ware as follows. Results: 1) Absence of cystic change, presence of internal hypoechogenicity, lobulation, calcification, thick and irregular halo, and nodule more than 4cm in diameter on U/S were considered significant statistically for the diagnosis of malignancy(Chi-square test, p<0.05) 2) Presence of internal hypoechogenicity or thick and irregular halo has the validity in Logistic regression analysis. 3) FNAC was done in 65 case. 19 case were malignant, 11 case were suspicious and 46 patients were benign (sensitivity 52.6%, specificity 87%). 4) The findings of U/S which are hypoechogenic and thick and irregular halo show 82% sensitivity and 97% specificity. In combination with the findings of FNAC that imply benign or suspicious lesions, the sensitivity was 100% and the specificity was 97%. Conclusion: This study suggest that the hypoechogenicity and thick and irregular halo on U/S are important information for the diagnosis of thyroid malignancy which were considered benign or suspicious after FNAC.

  • PDF

전악치근단방사선사진촬영, 파노라마방사선사진촬영 및 협각단층촬영시의 흡수선량 (Absorbed Dose in the Full-mouth Periapical Radiography, Panoramic Radiography, and Zonography)

  • 최순철;최항문
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.255-260
    • /
    • 1999
  • Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  • PDF

렌바티닙 사용과 관련된 고혈압과 단백뇨의 관리: 증례 보고 (Management of Hypertension and Proteinuria after Treatment with Lenvatinib for Radioiodine Refractory Papillary Thyroid Carcinoma: a Case Report)

  • 송의연;김원구
    • International journal of thyroidology
    • /
    • 제11권2호
    • /
    • pp.78-81
    • /
    • 2018
  • Lenvatinib, an oral multi-kinase inhibitor, is a valuable treatment option for advanced differentiated thyroid carcinoma. However, severe treatment-related adverse events occur up to 30% of the patients receiving lenvatinib, making it a challenge for clinicians to maintain this drug and therefore affecting the outcome of therapy. Blood vessel related events, such as hypertension or proteinuria, are among the most frequent adverse events. We present a case of 65-year-old man with radioactive iodine refractory papillary thyroid carcinoma with cervical lymph node metastasis and tracheal invasion receiving lenvatinib who developed proteinuria and worsening of hypertension. Management with repeated dose reductions and using supportive medications allowed this patient to continue lenvatinib with his disease stably controlled. Early detection of patients at risk for these adverse events and cautious administration of lenvatinib at appropriate level are crucial in managing patients receiving lenvatinib.

직.간접디지털 파노라마 방사선촬영시 흡수선량과 유효선량 (Absorbed and effective dose in direct and indirect digital panoramic radiography)

  • 이근선;김진수;김재덕
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.9-14
    • /
    • 2010
  • Purpose : We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. Materials and Methods : The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), $^nLi_2B_4O_7$ TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. Results : The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p<0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. Conclusion : The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

Graves' Disease Patients with Large Goiters Respond Best to Radioactive Iodine Doses of at Least 15 mCi: a Sonographic Volumetric Study

  • Jeong, Yun Ah;Yoon, Jee Hee;Kim, Hee Kyung;Kang, Ho-Cheol
    • International journal of thyroidology
    • /
    • 제11권2호
    • /
    • pp.137-142
    • /
    • 2018
  • Background and Objectives: Radioactive iodine therapy (RAI) is an important treatment modality of Graves' disease (GD), but there is still not a consensus on the optimal dosage regimen. We studied the treatment success rate of different RAI doses, and examined which clinical markers were useful for determining the optimal RAI dosage for successful therapy in Korean patients. Materials and Methods: We retrospectively studied 123 patients with GD treated with RAI between 2004 and 2014 at Chonnam National University Hwasun Hospital. The responder group was defined as patients who developed hypothyroidism requiring levothyroxine replacement following RAI, regardless of the RAI dosage. Results: A total of 54 patients (43.9%) became hypothyroid after the first dose, and 31 needed two to four additional doses to achieve hypothyroidism. In the responder group as a whole (85 patients), the mean total dose of RAI was $15.5{\pm}7.0mCi$ and the mean thyroid volume (TV) was $35.4{\pm}23.4mL$. When divided into low dose (<15 mCi, n=46) and high dose (${\geq}15mCi$, n=39) responder groups, TV was significantly lower in the low-dose responder group ($25.7{\pm}11.4$ vs. $48.4{\pm}31.3$, p<0.001). The optimal cut-off TV for the low-dose responder group was <32.37 mL (sensitivity 80.9%, specificity 76.7%). Conclusion: TV had significant effects on the outcome of RAI in GD patients. The optimal fixed RAI dose for Korean GD patients with a large goiter (${\geq}33mL$) should be at least 15 mCi to achieve the best outcome.

Effect of Low-level Laser Therapy on Propylthiouracil-induced Hypothyroidism Model Mice: A Pilot Study

  • Mun, In Kwon;Yoo, Won Sang;Lee, Sang Joon;Chung, Phil-Sang;Woo, Seung Hoon
    • Medical Lasers
    • /
    • 제10권1호
    • /
    • pp.37-44
    • /
    • 2021
  • Background and Objectives Hypothyroidism is the most common endocrine disease. On the other hand, there is no treatment that can improve the thyroid function. Low-level laser therapy (LLLT) can improve the cellular activity. The effect of hypothyroidism is not obvious. This study examined the effects of LLLT on the thyroid gland function of a propylthiouracil (PTU)-induced hypothyroidism mouse model. Materials and Methods Twenty-five male ICR mice were distributed into five groups of five animals each: Negative control (none PTU animal) and positive control (PTU animal) of unirradiated animals, and three experimental groups with LLLT (3J, 6J, and 12J). Each mouse was exposed to a distinct dose of a 632-nm laser once a week for three rounds. The positive control group and three LLLT groups were induced into a hypothyroidism state by PTU administration. The animals' thyroid-stimulating hormone and thyroxine levels were measured using an ELISA kit, and their thyroid tissue was harvested and analyzed after sacrifice at the end of the experiment. The hormone level and morphological changes in the tissue of the five groups were compared. Results The thyroid hormone levels in the control group and LLLT groups were similar. On the other hand, the thyroid tissue of the LLLT groups showed some morphological changes that were similar to those of iodine deficiency thyroid. Conclusion LLLT did not affect the thyroid gland function in PTU-induced hypothyroidism mice.

갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정 (Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer)

  • 김명선;정내인;이재용;김종순;김종호;이명철;고창순;김희근;강덕원;송명재
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.124-132
    • /
    • 1994
  • 서론 : 방사성옥소는 갑상선암 환자에서 수술요법과 병용하여 많이 쓰이고 있으나 환자에 따라 방사성옥소 흡수량과 배설량, 암조직의 방사성옥소 섭취율이 차이가 나기 때문에 같은 양을 투여하더라도 치료효과나 부작용이 차이가 날 수 있다. 그러므로 본 연구에서는 체내 피폭된 물리적 선량을 측정하여 치료효과와 방사선영향의 정도를 비교하였다. 방법 : 수술요법을 시행한 분화된 갑상선암 환자 27명을 대상으로 하여 100mCi 150mCi, 200mCi의 방사성옥소를 투여하고 BEL DOSIMETRY PROTOCOL에 따라 방사선량을 구하고 반대수 용지위에 혈액 리터당 투여량에 대한 백분율의 로그값, 잔류량 백분율과 시간의 관계를 그래프로 그려 베타선량과 감마선량을 구한 뒤 총 물리학적 선량을 구하였다. 결과 : 1) 100mCi 투여군에서 물리적 선량은 평균 $56.54{\pm}13.02$ rad 이었고 150 mCi 투여군에서는 $76.83{\pm}19.97$ rad, 200mCi 투여군에서는 $95.08{\pm}25.51$ rad 이었고 각 평균값 사이에는 유의한 상관관계가 있었다. 2) 48시간후 체내 잔류율은 평균 26.34% 이었다. 3) 전이여부와 물리적 선량과의 사이에 유의한 상관관계는 없었다. 4) 갑상선 글로불린과 갑상선 자극 호르몬, Thallium scan으로 추적 관찰한 19명중 17명이 치유되었다. 5) 백혈구, 림프구, 호중구, 혈소판 모두 4-6주에 최저치로 감소한뒤 3개월내에 회복되었다. 6) 물리적 선량과 생물학적 선량 사이에 유의한 상관관계는 없었다. 결론 : 우리나라에서 수술후 갑상선암의 치료에 통상적으로 사용하는 방사성옥소의 양(100-200mCi)은 일시적 골수부전과 경도의 염색체 이상을 초래하나 혈액내방사선 조사량이 안전용량 범위(200rad)에 속하며 48시간 후 체내잔류량은 서양인과 큰 차이가 없었다.

  • PDF

각종(各種) 갑상선질환(甲狀腺疾患)의 $^{99m}Tc$-pertechnetate 갑상선섭취(甲狀腺攝取)에 관(關)한 연구(硏究) (A Study on $^{99m}Tc$-pertechnetate thyroid uptake in various thyroid diseases)

  • 최성재;민혜숙;고창순;이문호
    • 대한핵의학회지
    • /
    • 제8권1_2호
    • /
    • pp.29-37
    • /
    • 1974
  • The $^{99m}Tc$-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between $^{99m}TcO_4$-thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows 1. The $^{99m}TcO_4$-thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were $4.1{\pm}0.9%,\;5.2{\pm}1.8%\;and\;29.7{\pm}10.6%$. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2. In the diagnosis of hyperthyroidism, the reliabilities of $^{99m}TcO_4$- thyroid uptake rate(20 min), $^{131}I$ thyroid uptake rate(24hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7\;were\;87.9{\sim}97.9%,\;81.2{\sim}94.4%,\;87.9{\sim}97.9%,\;90.5{\sim}99.3%\;and\;93.7{\sim}100%$. $^{99m}TcO_4$-thyroid uptake rate(20 min) is more accurate than $^{131}I$ thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3. $^{99m}TcO_4$-thyroid uptake rate (20 min) was well correlated with $^{131}I$ thyroid uptake rate (24 hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7$. Points in favor of $^{99m}Tc$ are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  • PDF

저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰 (Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration)

  • 김일수;김호신;류형기;강영직;박수영;김승찬;이귀원
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.32-36
    • /
    • 2016
  • 핵의학검사에서 $^{131}I$은 갑상선암 및 질환의 진단, 치료등 핵의학 검사에서 많이 사용되고 있다. $^{131}I$${\gamma}$선과 ${\beta}^-$선을 방출하여 검사와 치료를 할 수 있고, 높은 집적율과 신장을 통한 빠른 배설이 용이 하지만, $^{131}I$(364 keV)은 $^{99m}Tc$(140 keV)보다 고에너지이기 때문에 작업을 수행 시 조작 및 투여 과정에서 $^{99m}Tc$보다 술자의 피폭을 줄이기 위해 외부피폭 방어의 3요소인 거리, 시간, 차폐 중에 차폐에 주안점을 두어 $^{131}I$ 조작 시 차 폐체 착용 전과 후의 피폭선량의 차이를 비교하고자 한다. Apron(보통 Pb 0.5 mm) 착용 시 $^{99m}Tc$은 90%이상이 차폐가 되지만, $^{131}I$은 고에너지이기 때문에 차폐효과가 비교적 낮고, 고용량의 경우 산란선(2차) 및 제동방사선의 영향으로 오히려 더 피폭을 받을 수 있다. 하지만 저용량(74 MBq) 고에너지의 경우 이에 대한 특별한 보고나 Guide Line이 마련되어 있지 않아, $^{131}I$ 조작 시 Apron 착용 유무에 따른 술자의 피폭선량을 정량적으로 분석하고자 한다. 본원 핵의학과에서 2014년 6월부터 2014년 12월까지 7개월 동안 갑상선암 치료 및 진단을 위한 저용량$^{131}I$을 투여하기 위해 방문한 갑상선암 환자를 대상으로 준비과정부터 투여 시까지 연구기간 동안 갑상선, 가슴, 고환 3곳에 Apron 안쪽과 바깥쪽 각각 1개씩 총 6개의 TLD를 부착한 뒤 $^{131}I$검사 과정부터 투여 시 까지의 방사선 피폭선량을 측정하였다. 총 작업시간은 설명시간 3분, 분배시간 1분, 투여시간 1분으로 각각 1인당 5분이내로 설정하였다. TLD 위치설정은 일반적으로 피폭선량을 측정하는 가슴과 방사선 감수성이 높은 갑상선 및 고환으로 설정하였다. 준비과정은 $^{131}I$$2m{\ell}$ 주사기를 이용해 74MBq을 분배한 뒤 생리식염수와 희석해 $2m{\ell}$의 용량을 만들어 분배한다. $^{131}I$을 분배 후 환자에게 투여 시 컵에 물을 $100m{\ell}$ 담고 분배한 $^{131}I$을 희석하여 환자 1 m 정도 거리를 두고, 경구투여 한다. 그리고 경구투여 한 $2m{\ell}$ 주사기와 컵을 폐기하는 과정을 Apron과 TLD를 착용한 상태에서 시행하였다. Apron과 TLD는 방사선 피폭이 미치지 않는 보관실에 따로 보관하였고, 서울방사선 서비스에 의뢰하여 피폭선량을 측정하였다. 연구기간 동안 저용량 $^{131}I$ 검사 시 갑상선, 가슴, 고환 부위에 Apron 안과 밖d[착용한 TLD의 매월 누적선량을 인원수로 나눈 결과를 가지고, SPSS Version. 12.0K를 이용해 Wilcoxon Signed Rank Test를 사용하여 통계를 시행하였다. 그 결과 갑상선(p = 0.345), 가슴(p = 0.686), 고환(p = 0.715)은 모두 p > 0.05으로 유의한 차이가 없음을 알 수 있었다. 그리고 연구기간 동안의 총 누적선량의 변화를 백분율로 환산하였을 때, 갑상선 -23.5%, 가슴 -8.3%, 고환 19.0%로 나타났다. Wilcoxon Signed Rank Test를 사용한 결과 통계적으로 유의한 차이가 없는 것으로 나타났다(p > 0.05). 또한 7개월간의 누적선량으로 차폐율을 계산 했을 때 에는 Apron 안쪽과 바깥쪽의 피폭선량의 변화가 불규칙적으로 나타나는 결과를 보였다. 이 결과는 백분율로 표현 시 변화폭이 커보이지만, 누적 피폭선량이 소수점 이하이므로 큰 변화라고 보기 어렵다. 그러므로 고에너지 저용량 $^{131}I$ 투여 시 Apron을 착용유무와 상관없이 일정한 거리를 두고 최대한 빠른 시간 내에 투여를 종료하는 것이 피폭선량을 줄이는 데 도움이 될 것이다. 본 연구는 $^{131}I$ 투여시간을 1인당 각 5분 이내로 투여 할 수 있도록 제한하고, 거리를 1 m로 일정하게 하여 작업 할 수 있도록 하였으나 통계 시 N수가 적어서 비모수적인 방법으로 통계를 시행함으로써 정확한 결과를 얻기에 부족한 부분이 있었다. 또한 저용량 $^{131}I$ 투여 시 각 1인당 피폭선량을 직독식 선량으로 측정하지 못하고, TLD를 이용한 누적선량으로 측정한 결과 값이므로 전자선량계 및 포켓선량계를 이용한 측정이 이루어진다면 더 효과적인 결과를 얻을 수 있을 것으로 사료된다.

  • PDF