• 제목/요약/키워드: Throttling step

검색결과 3건 처리시간 0.017초

Investigation on cavitating flow and parameter effects in a control valve with a perforated cage

  • Wang, Hong;Zhu, Zhimao;Zhang, Miao;Li, Jie;Huo, Weiqi
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2669-2681
    • /
    • 2021
  • Valve is widely used in the various industry areas to adjust and control the flow. Cavitation frequently takes place and sometimes is inevitable in various types of valve to cause the erosion damage. Therefore, how to control and minimize the effect of cavitation is still an important topic. This study numerically investigates the cavitating flow in a control valve with a perforated cage. The effects of some parameters on the cavitation are discussed. It also discusses to use the throttling steps to govern the cavitating flow. The results show that the opening degree of valve and the length of downstream divergent connection both influence the cavitation. The increase of the divergent length reinforces the cavitation. And the larger the opening of valve is, the intenser the cavitation is and the more vapor is present. The more throttling steps are helpful to decrease the cavitation.

SSD기반 RAID 시스템에서 빅데이터 유지 보수의 신뢰성을 향상시키기 위한 차등 수명 마감을 유도하는 안전한 IO 조절 기법 (A Safety IO Throttling Method Inducting Differential End of Life to Improving the Reliability of Big Data Maintenance in the SSD based RAID)

  • 이현섭
    • 디지털융복합연구
    • /
    • 제20권5호
    • /
    • pp.593-598
    • /
    • 2022
  • 최근 데이터의 생산량은 폭발적인 증가를 이루어왔고, 빅데이터를 안전하고 빠르게 저장하기 위한 대용량 저장 시스템이 다양하게 발전하고 있다. 저장시스템의 대표적인 구성은 빠른 데이터 처리속도를 가지고 있는 SSD를 신뢰성 높은 데이터 유지 보수가 가능한 RAID 그룹으로 사용하는 것이다. 그러나 SSD를 구성하는 낸드 플래시 메모리는 특정 횟수 이상 쓰기를 반복할 경우 열화가 발생하는 특징이 있기 때문에 RAID 그룹의 여러 SSD에서 동시에 불량이 발생할 가능성을 증가시킬 수 있다. 그리고 이러한 동시성 불량은 데이터를 복구할 수 없는 심각한 신뢰성의 문제를 초래할 수 있다. 따라서 본 논문에서는 이러한 문제를 해결하기 위해 RAID 그룹 내에서 각 SSD가 차등으로 수명 마감이 유도되도록 IO를 조절하는 방법을 제안한다. 본 논문에서 제안하는 기법은 SMART를 활용하여 각 SSD의 상태와 사용된 데이터 패턴에 따라 할당되는 IO 횟수를 단계별로 조절한다. 그리고 이 방법은 SSD의 차등 수명마감을 유도하기 때문에 RAID에서 대량의 동시성 불량이 발생하는 것을 방지하는 장점이 있다.

Development of stability maps for flashing-induced instability in a passive containment cooling system for iPOWER

  • Lim, Sang Gyu;No, Hee Cheon;Lee, Sang Won;Kim, Han Gon;Cheon, Jong;Lee, Jae Min;Ohk, Seung Min
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.37-50
    • /
    • 2020
  • A passive containment cooling system (PCCS) has been developed as advanced safety feature for innovative power reactor (iPOWER). Passive systems are inherently less stable than active systems and the PCCS encountered the flashing-induced instability previously identified. The objective of this study is to develop stability maps for flashing-induced instability using MARS (Multi-dimensional Analysis of Reactor Safety) code. Firstly, we conducted a series of sensitivity analysis to see the effects of time step size, nodalization, and alternative MARS user options on the onset of flashing-induced instability. The riser nodalization strongly affects the prediction of flashing in a long riser of the PCCS, while time step size and alternative user options do not. Based on the sensitivity analysis, a standard input and an analysis methodology were set up to develop the stability maps of PCCS. We found out that the calculated equilibrium quality at the exit of the riser as a stability boundary above 5 kW/㎡ was approximately 1.2%, which was in good agreement with Furuya's results. However, in case of a very low heat flux condition, the onset of instability occurred at the lower equilibrium quality. In addition, it was confirmed that inlet throttling reduces the unstable region.