• Title/Summary/Keyword: Threshold Velocity

Search Result 180, Processing Time 0.029 seconds

Effect of Hydrogen Addition on Autoignited Methane Lifted Flames (자발화된 메탄 부상화염에 대한 수소 첨가의 영향)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Autoignited lifted flames in laminar jets with hydrogen-enriched methane fuels have been investigated experimentally in heated coflow air. The results showed that the autoignited lifted flame of the methane/hydrogen mixture, which had an initial temperature over 920 K, the threshold temperature for autoignition in methane jets, exhibited features typical of either a tribrachial edge or mild combustion depending on fuel mole fraction and the liftoff height increased with jet velocity. The liftoff height in the hydrogen-assisted autoignition regime was dependent on the square of the adiabatic ignition delay time for the addition of small amounts of hydrogen, as was the case for pure methane jets. When the initial temperature was below 920 K, where the methane fuel did not show autoignition behavior, the flame was autoignited by the addition of hydrogen, which is an ignition improver. The liftoff height demonstrated a unique feature in that it decreased nonlinearly as the jet velocity increased. The differential diffusion of hydrogen is expected to play a crucial role in the decrease in the liftoff height with increasing jet velocity.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

Carpal Tunnel Syndrome among workers in a condom industry (한 콘돔공장근로자들의 수근관증후군에 관한 연구)

  • Kang, Joong-Koo;Paek, Do-Myung;Lee, Young-Jung;Ma, Hyeo-Il;Son, Mi-A;Lee, Hong-Ki;Choi, Jung-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.507-519
    • /
    • 1996
  • The objectives of this study are to investigate the prevalence of occupation related carpal tunnel syndrome(CTS) among workers in a condom industry : to analyse the sensitivity and specificity of clinical signs or symptoms such as hand diagram, Tinel's sign and Phalen's sign in carpal tunnel syndrome : and to test vibration threshold test using audiometry as a technically easy and noninvasive method in the diagnosis of carpal tunnel syndrome in stead of nerve conduction velocity (NCV). The study group was divided into exposed group(39 cases) and non-exposed group(48 cases) based on whether or not excessive use of wrist movements exsist. 1. There are stastically significant differences in symptoms and signs of carpal tunnel syndrome such as hand diagram, Tinel's sign and Phalen's sign between exposed and non-exposed group(p<0.05). 2. Six cases(9 hands) were comfirmed as carpal tunnel syndrome by NCV. Five cases(7 hands) belonged to exposed group, 1 case(2 hands) to nonexposed group. As there are significant differences in prevalence of carpal tunnel syndrome between two groups(p<0.05), excessive use of wrist in occupation is a risk factor of carpal tunnel syndrome. 3. When we use NCV as a gold standard in the diagnosis of carpal tunnel syndrome, sensitivity and specificity of hand diagram, Tinel's sign and Phalen's sign is as followed; hand diagram , sensitivity 88.9%, specificity 84.2% Tinel's sign ; sensitivity 55.6%, specificity 72.8% Phalen's sign ; sensitivity 14.3%, specificity 88.4%. Among above clinical signs and symptoms, hand diagram is the best clinical screening test. 4. The differences of vibration threshold between median and ulnar nerve at the same time are useful in the diagnosis of carpal tunnel syndrome but the time change of vibration threshold of median nerve over time are not sensitive enough. It is concluded that vibration threshold between median and ulnar nerve at the same time can be used as a supplementary or alternative criterion to indicate that the nerve dysfunction is located in the carpal tunnel.

  • PDF

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

A study on Development of Precise Orientation control Algorithm of the Mobile Robot Based Vision Technology (비전기술에 의한 모바일 로봇의 정밀 자세 제어 알고리즘 개발에 관한 연구)

  • Sim, Hyun-Seok;Kim, Tae-Gwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.18 no.2
    • /
    • pp.129-138
    • /
    • 2015
  • This study describe a new method to control posture and velocity for a wheeled mobile robot using visual feedback control method with a position based visual feedback. To slove the problem of vibration phenomena which were shown in the previous researches using a simple switching function based on a threshold, the proposed visual servo control law introduces the fusion function based on a blending function. The chattering problem and rapid motion of the mobile robot can be eliminated. And we consider the nonlinearity of the wheeled mobile robot unlike the previous visual servo control laws using linear control methods to improve the performances of the visual servo control law. The proposed posture control law using visual servoing is verified by a theoretical analysis and simulation and experimental results.

Molecular Dynamics Study on the Binary Collision of Nanometer-Sized Droplets of Liquid Argon

  • Chun, In-Beom;Ha, Man-Yeong;Jang, Joon-Kyung;Yoon, Hyun-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2027-2031
    • /
    • 2011
  • Molecular dynamics simulation is used to study the binary collisions of nanometer-sized droplets of argon in the presence of a surrounding gas. By systematically varying the droplet size, the impact parameter and the velocity of collision, the outcome of such collisions were examined and they can be classified into coalescence, separation and shattering. If one of the colliding droplets is half or less than the other in diameter, a shattering is not possible to occur. The threshold of impact parameter for a given separation was studied by adjusting the Weber number. Overall nanoscale droplets were more likely to coalesce than the macroscopic sized ones due to their high surface-to-volume ratio.

Visualization of Electro-osmotic Flow Instability in a T-shape Microchannel (T자형 마이크로 채널 내부 전기삼투 유동의 불안정성 가시화)

  • Han, Su-Dong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.45-50
    • /
    • 2005
  • Electro-osmotic flow (EOF) instability in a microchannel has been experimentally investigated using a micro-PIV system. The micro-PIV system consisting of a two-head Nd:Yag laser and cooled CCD camera was used to measure instantaneous velocity fields and vorticity contours of the EOF instability in a T-shape glass microchannel. The electrokinetic flow instability occurs in the presence of electric conductivity gradients. Charge accumulation at the interface of conductivity gradients leads to electric body forces, driving the coupled flow and electric field into an unstable dynamics. The threshold electric field above which the flow becomes unstable and rapid mixing occurs is about 1000V/cm. As the electric field increases, the flow pattern becomes unstable and vortical motion is enhanced. This kind of instability is a key factor limiting the robust performance of complex electrokinetic bio-analytical devices, but can also be used for rapid mixing and effective flow control fer micro-scale bio-chips.

  • PDF

A Study on the Injury Criteria of the Occupant Protection Performance of Crush Cushions (충격흡수시설의 탑승자보호 성능평가 기준에 관한 연구)

  • Lim, Jae-Moon;Jung, Geun-Seup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • The performance of crash cushion systems is certified through the full scale crash tests by the standard for installation and maintenance guidelines for roadside safety appurtenance. The impact severities of impacting vehicles in collision with crash cushion systems are rated by indices THIV and PHD. Crash test results are considered to study the performance of three crash cushion systems. In case of the frontal impact or the offset frontal impact, the results show that THIV values of three systems are very close to the threshold limit for the occupant protection. Also, the results show that PHD would be improper for the occupant protection performance index. In order to improve the occupant protection performance of crash cushions, ASI needs to be included in the impact severity index.

Determination of Decision Boundary Using Feature Values in the Signature Verification (서명검증에서 특징값을 고려한 판단 경계 설정에 관한 연구)

  • 이흥열;김재희
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.464-467
    • /
    • 1999
  • Usually, more reference signatures result in better performance in signature verification. However, registering .many signatures may be a tedious work for users, so algorithms that use less signatures for the registration without increasing error rate is needed. In this paper, we find the features such as pen-down duration, the number of locally minimum velocity points, and the number of locally maximum curvature points. Then we find the relationship between these features and the optimal decision boundary. We apply this relationship in deciding threshold for signature verification. Experimental results show that the method using three reference signatures has almost same error rate as algorithms with many references.

  • PDF

A Fast Lower Extremity Vessel Segmentation Method for Large CT Data Sets Using 3-Dimensional Seeded Region Growing and Branch Classification

  • Kim, Dong-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.348-354
    • /
    • 2008
  • Segmenting vessels in lower extremity CT images is very difficult because of gray level variation, connection to bones, and their small sizes. Instead of segmenting vessels, we propose an approach that segments bones and subtracts them from the original CT images. The subtracted images can contain not only connected vessel structures but also isolated vessels, which are very difficult to detect using conventional vessel segmentation methods. The proposed method initially grows a 3-dimensional (3D) volume with a seeded region growing (SRG) using an adaptive threshold and then detects junctions and forked branches. The forked branches are classified into either bone branches or vessel branches based on appearance, shape, size change, and moving velocity of the branch. The final volume is re-grown by collecting connected bone branches. The algorithm has produced promising results for segmenting bone structures in several tens of vessel-enhanced CT image data sets of lower extremities.