• 제목/요약/키워드: Three-dimensional effect

검색결과 2,336건 처리시간 0.024초

터널 굴진시의 3차원 지반거동의 2차원적 해석법 고찰 (A Study tor 2-Dimensional Analysis Technique for 3-Dimensional Ground Behaviour Due to Tunneling)

  • 김교원;이현범
    • 지질공학
    • /
    • 제6권3호
    • /
    • pp.111-118
    • /
    • 1996
  • 터널이 굴진될 때 주변지반은 3차원적으로 거동하게 되나 설계단계에서의 해석은 일반적으로 2차원적으로 수향하고 있다. 2차원적인 터널해석은 응력분배법 또는 강송 변화법에 의하여 3차원적인 터널굴진에 따른 다양한 조건하에서의 정규화된 지반 변위곡선을 구하고 이 곡선과 유사한 곡선이 유도되도록 시행착오법에 의하여 2차원 해석을 실시하므로 3차원 해석과 근사한 변위곡선을 가지도록 막장거리별 응력분배비율을 결정하였다. 따라서, 시간과 노력이 많이 소요되는 3차원 해석없이도 적절한 응력분배비율을 적용하는 경우 2차원 해석으로 터널굴진시의 3차원적인 지반거동을 평가할 수 있게 되었다.

  • PDF

사면보강 뿌리말뚝공법의 준3차원적 안정해석기법 (Method of Quasi-Three Dimensional Stability Analysis of the Root Pile System on Slope Reinforcement)

  • 김홍택;강인규;박사원
    • 한국지반공학회지:지반
    • /
    • 제13권5호
    • /
    • pp.101-124
    • /
    • 1997
  • The root pile system is insitu soil reinforcement technique that uses a series of reticulately installed micropiles. In terms of mechanical improvement by means of grouted reinform ming elements, the root pile system is similar to the soil nailing system. The main difference between root piles and soil nailing are due to the fact that the reinforcing bars in root piles are normally grouted under high pressure and that the alignments of the reinforcing members differ. Recently, the root pile system has been broadly used to stabilize slopes and retain excavations. The accurate design of the root pile system is, however, a very difficult tass owing to geometric variety and statical indetermination, and to the difficulty in the soilfiles interaction analysis. As a result, moat of the current design methods have been heavily dependent on the experiences and approximate approach. This paper proposes a quasi-three dimensional method of analysis for the root pile system applied to the stabilization of slopes. The proposed methods of analysis include i) a technique to estimate the change in borehole radium as a function of the grout pressure as well as a function of the time when the grout pressure is applied, ii) a technique to evaluate quasi -three dimensional limit-equilibrium stability for sliding, iii) a technique to predict the stability with respect to plastic deformation of the soil between adjacent root piles, and iv) a quasi -three dimensional finite element technique to compute stresses and dis placements of the root pile structure barred on the generalized plane strain condition and composite unit cell concept talon형 with considerations of the group effect and knot effect. By using the proposed technique to estimate the change in borehole radius as a function of the grout pressure as well as a function of the time, the estimations are made and compar ed with the Kleyner 8l Krizek's experimental test results. Also by using the proposed quasi-three dimensional analytical method, analyses have been performed with the aim of pointing out the effects of various factors on the interaction behaviors of the root pile system.

  • PDF

( )

  • 김길창
    • 정보과학회지
    • /
    • 제2권1호
    • /
    • pp.04-06
    • /
    • 1984
  • Representation of three dimensional objects on a CRT screen is usually done by means of a perspective view, hidden line removal enhances three dimensional effect and an algorithm based on existing methods is studied.Actual implementation was carried out on No.A 840 with Tektronix 4010 graphic display.

축대칭 핀틀노즐의 3차원 효과 분석 (Three-dimensional Effects of an Axi-symmetric Pintle Nozzle)

  • 이강민;성홍계
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.47-55
    • /
    • 2018
  • 축 대칭 형상의 핀틀 노즐에서 3차원 효과 여부를 파악하기 위하여 3차원 수치해석을 수행하였다. 초음속 노즐을 통해 배출되는 압축성 유동을 정확히 예측하기 위해 k-${\omega}$ SST 난류 모델에 압축성 보정 모델을 결합하였다. 핀틀의 전단과 후단에서 재순환 영역이 관찰되었으며, 노즐을 통해 분출되는 유동은 복잡한 충격파 구조를 형성하였다. 각 핀틀 위치에서 2차원 축대칭과 3차원의 수치해석 결과를 실험데이터와 비교해 볼 때 3차원 결과가 접선 방향 유동의 3차원 효과로 인해 유동 박리 위치와 박리로 인한 압력 상승 변화과정을 정확히 예측하였다.

3차원 전극을 사용한 Rhodamine B의 전기분해에 미치는 운전인자의 영향 (Effect of Operating Parameters on Electrochemical Degradation of Rhodamine B by Three-dimensional Electrode)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제35권4호
    • /
    • pp.295-303
    • /
    • 2009
  • A simulated wastewater containing the dye Rhodamine B (RhB) was electrolytically treated using a three-dimensional electrode reactor equipped with granular activated carbon (GAC) as particle electrode. The effect of type of packing material (GAC, ACF, Nonwoven fabric fiber coated with activated carbon), amounts of GAC packing (25-100 g), current (0.5-3 A) and electrolyte concentration (0.5-3 g/l) was evaluated. Experimental results showed that performance for RhB decolorization of the 3 three-dimensional electrodes lie in: GAC > Nonwoven fabric fiber > ACF. When considered RhB decolorization, oxidants concentration and electric power, optimum GAC dosage was 50 g. Generated concentration of 3 oxidants ($ClO_2$, free Cl, $H_2O_2$) was increased with increase of applied current, however optimum current for RhB degradation was 2.5 A. The oxidants concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.5 g/l.

3차원 계측시스템을 이용한 개더스커트 형상 분석 (Analysis of the Shape of Gathered Skirts using a Three-Dimensional Measurement System)

  • 정희경;이명희
    • 한국의류학회지
    • /
    • 제29권11호
    • /
    • pp.1399-1409
    • /
    • 2005
  • The purpose of this study was to analyze the shape of gathered skirts using a three-dimensional measurement system. And in this experiment, I try to accumulate three-dimensional data of wearing model and to figure out analyzing method made by shape of clothes. The experimental design consists of two factorial designs. I set up three different kinds of fabrics, ratio of gathers. Therefore nine samples were made. The instrument and tools for three-dimensional measurement was whole body 3D scanner. Analysis program used in experiment is RapidForm 2004 PP1 and Pattern Design 2000. Data analysis utilizes SPSS WIN 10.0 Package. T-test to effect an inspection of evidence, there was difference about measurement times. One-way ANOVA to analysis effect of gather made by gathering conditions. The following results were obtained; 1. As a result of inspecting an error several times using a three-dimension measurement system, convinced data was obtained. 2. At front, distribution of gap amount was larger than back. And as ratio of gathers increased, distribution of gap amount showed regularly. 3. After analyzing horizontal sectional figure of skirts, as a height of skirt changed from waist to the bottom of skirts, the results showed as follows. While section width, section thickness, node width, node depth increased, node count decreased. 4. With the horizontal section levels of gather skirt, the silhouette on middle hip section was similar with the silhouette of body line. And as ratio of gathers around hip section increased, nodes showed regularly. At the bottom of skirts showed different nodes by different gathering condition.

옥외 전기시설물 침수시 누설전류에 의한 인체영향 (Human Hazard by Outdoor Electrical Facilities in Submerged Area)

  • 하태현;이현구;배정효;김대경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.

Three-Dimensional Flow Analysis and Improvement of Slip Factor Model for Forward-Curved Blades Centrifugal Fan

  • Guo, En-Min;Kim, Kwang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.302-312
    • /
    • 2004
  • This work developed improved slip factor model and correction method to predict flow through impeller in forward-curved centrifugal fan. Both steady and unsteady three-dimensional CFD analyses were performed to validate the slip factor model and the correction method. The results show that the improved slip factor model presented in this paper could provide more accurate predictions for forward-curved centrifugal impeller than the other slip factor models since the present model takes into account the effect of blade curvature. The correction method is provided to predict mass-averaged absolute circumferential velocity at the exit of impeller by taking account of blockage effects induced by the large-scale backflow near the front plate and flow separation within blade passage. The comparison with CFD results also shows that the improved slip factor model coupled with the present correction method provides accurate predictions for mass-averaged absolute circumferential velocity at the exit of impeller near and above the flow rate of peak total pressure coefficient.

SOI 소자 셀프-히팅 효과의 3차원적 해석 (Three-Dimensional Analysis of Self-Heating Effects in SOI Device)

  • 이준하;이흥주
    • 반도체디스플레이기술학회지
    • /
    • 제3권4호
    • /
    • pp.29-32
    • /
    • 2004
  • Fully depleted Silicon-on-Insulator (FD-SOI) devices lead to better electrical characteristics than bulk CMOS devices. However, the presence of a thin top silicon layer and a buried SiO2 layer causes self-heating due to the low thermal conductivity of the buried oxide. The electrical characteristics of FDSOI devices strongly depend on the path of heat dissipation. In this paper, we present a new three-dimensional (3-D) analysis technique for the self-heating effect of the finger-type and bar-type transistors. The 3-D analysis results show that the drain current of the finger-type transistor is 14.7% smaller than that of the bar-type transistor due to the 3-D self-heating effect. We have learned that the rate of current degradation increases significantly when the width of a transistor is smaller that a critical value in a finger-type layout. The current degradation fro the 3-D structures of the finger-type and bar-type transistors is investigated and the design issues are also discussed.

  • PDF

A ROBUST METHOD MINIMIZING DIGITIZATION ERRORS IN SKELETONIZATION OF THREE DIMENSIONAL BINARY SEGMENTED IMAGE

  • Shin, Hyun-Kyung
    • Journal of applied mathematics & informatics
    • /
    • 제15권1_2호
    • /
    • pp.425-434
    • /
    • 2004
  • Pattern recognition in three dimensional image is highly sensitive to assigned value and formation of voxels (pixels for two dimension case). However, occurred while digital imaging, digitization error leads to unpredictable noises in image data. Skeletonization, a powerful tool of pattern recognition, is sensitively dependent on boundary formation. Without successful controlling of the noises, the results of skeletonization can not be allowed as a stable solution. To minimize the effect of noises affecting to boundary formation, we developed a robust processing method useful in skeletonization technique for pattern recognition. Finally, we provide rigorous test results achieved throughout simulation on analytic three dimensional image.