• Title/Summary/Keyword: Three-dimensional cone-beam computed tomography

검색결과 143건 처리시간 0.032초

Current status of dental caries diagnosis using cone beam computed tomography

  • Park, Young-Seok;Ahn, Jin-Soo;Kwon, Ho-Beom;Lee, Seung-Pyo
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.43-51
    • /
    • 2011
  • Purpose : The purpose of this article is to review the current status of dental caries diagnosis using cone beam computed tomography (CBCT). Materials and Methods : An online PubMed search was performed to identify studies on caries research using CBCT. Results : Despite its usefulness, there were inherent limitations in the detection of caries lesions through conventional radiograph mainly due to the two-dimensional (2D) representation of caries lesions. Several efforts were made to investigate the three-dimensional (3D) image of lesion, only to gain little popularity. Recently, CBCT was introduced and has been used for diagnosis of caries in several reports. Some of them maintained the superiority of CBCT systems, however it is still under controversies. Conclusion : The CBCT systems are promising, however they should not be considered as a primary choice of caries diagnosis in everyday practice yet. Further studies under more standardized condition should be performed in the near future.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

Effect of Voxel Size on the Accuracy of Landmark Identification in Cone-Beam Computed Tomography Images

  • Lee, Kyung-Min;Davami, Kamran;Hwang, Hyeon-Shik;Kang, Byung-Cheol
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.20-28
    • /
    • 2019
  • Purpose: This study was performed to evaluate the effect of voxel size on the accuracy of landmark identification in cone-beam computed tomography (CBCT) images. Materials and Methods: CBCT images were obtained from 15 dry human skulls with two different voxel sizes; 0.39 mm and 0.10 mm. Three midline landmarks and eight bilateral landmarks were identified by 5 examiners and were recorded as three-dimensional coordinates. In order to compare the accuracy of landmark identification between large and small voxel size images, the difference between best estimate (average value of 5 examiners' measurements) and each examiner's value were calculated and compared between the two images. Result: Landmark identification errors showed a high variability according to the landmarks in case of large voxel size images. The small voxel size images showed small errors in all landmarks. The landmark identification errors were smaller for all landmarks in the small voxel size images than in the large voxel size images. Conclusion: The results of the present study indicate that landmark identification errors could be reduced by using smaller voxel size scan in CBCT images.

상악동저와 상악 대구치 치근의 위치 관계: 파노라마방사선사진과 Cone beam형 전산화단층영상의 비교 (Comparison of panoramic radiography and cone beam computed tomography for assessing the relationship between the maxillary sinus floor and maxillary molars)

  • 정연화;조봉혜
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.69-73
    • /
    • 2009
  • Purpose: This study compared panoramic radiography and cone beam computed tomography (CBCT) for evaluating the relationship between the maxillary sinus floor and the roots of maxillary molars. Materials and Methods: Paired panoramic radiographs and CBCT images from 97 subjects were analysed. This analysis classified 388 maxillary molars according to their relationship to the maxillary sinus floor on panoramic radiograph and CBCT. Correlations between these two radiographic techniques were examined. Results: Maxillary molar roots that were separate from the sinus floor showed the same classification in 100% of the cases when using these two imaging techniques. The corresponding percentage for such roots that were in contact with the sinus floor was 75%. When roots overlapped the maxillary sinus floor on panoramic radiographs, only 26.4% of maxillary first molars and 60.0% of second molars showed protrusion of roots into the sinus with CBCT. Conclusion : The results of the study suggest that roots projecting into the sinus on panoramic radiographs require a three-dimensional image in order to analyze the proximity of their apex to the sinus floor. (Korean J Oral Maxillofac Radiol2009; 39 : 69-73)

  • PDF

A cone-beam computed tomography study on strategic uprighting of mandibular molars using a biocreative reverse curve system

  • Kim, Jae-Woo;Choi, Jin-Young;Kim, Min-Ji;Bin, Xu;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제52권5호
    • /
    • pp.354-361
    • /
    • 2022
  • Objective: To analyze the overall treatment effects in terms of the amount of uprighting with changes in the three-dimensional positions of the mandibular posterior teeth after applying the biocreative reverse curve (BRC) system. Methods: Thirty-four patients (mean age, 20.5 ± 8.56 years) were treated using the BRC system (mean period, 8.17 ± 2.19 months). Cone-beam computed tomography was performed before treatment and after treatment with the BRC system. The three-dimensional movement of each tooth was analyzed in the coordinate system at points on the crown and root apex. A paired t-test was used to analyze the treatment effects of the BRC system. Results: The application of the BRC system spanning from the first premolar to the second molar resulted not only in buccal and distal uprighting, but also in increased buccal and distal tipping of the teeth. The premolars and the first molar were extruded, and the second molar was intruded. Conclusions: When the BRC system is applied, simultaneous distal and buccal uprighting of the premolars and molars can be achieved bilaterally using a temporary skeletal anchorage device without unnecessary movement of the anterior teeth.

Effects of the cone-beam computed tomography protocol on the accuracy and image quality of root surface area measurements: An in vitro study

  • Chanikarn Intarasuksanti;Sangsom Prapayasatok;Natnicha Kampan;Supassara Sirabanchongkran;Pasuk Mahakkanukrauh;Thanapat Sastraruji;Pathawee Khongkhunthian;Kachaphol Kuharattanachai;Kanich Tripuwabhrut
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.325-333
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.

Differences in positions of cone-beam computed tomography landmarks in patients with skeletal Class III facial asymmetry according to midsagittal planes

  • Hyung-Kyu Noh;Ho-Jin Kim;Hyo-Sang Park
    • 대한치과교정학회지
    • /
    • 제53권4호
    • /
    • pp.219-231
    • /
    • 2023
  • Objective: This study aimed to clarify differences in the positions of cone-beam computed tomography (CBCT) landmarks according to different midsagittal planes (MSPs) in patients with skeletal Class III facial asymmetry. Methods: Pre-treatment CBCT data from 60 patients with skeletal Class III were used. The patients were classified into symmetric (menton deviations of < 2 mm) or asymmetric (menton deviations of > 4 mm) groups. Six MSPs were established based on previous studies, and three-dimensional analyses were performed for the planes in both the groups. The measurement outcomes were compared statistically. Results: A statistically significant interaction (p < 0.01) was observed between MSPs and facial asymmetry. No significant differences were observed among MSPs in the symmetric group. However, significant differences in linear measurements were identified among MSPs in the asymmetric group. Specifically, the upper facial MSP revealed both maxillary and mandibular transverse asymmetries. On the other hand, anterior nasal spine (ANS)-associated MSP could not identify maxillary asymmetry. Furthermore, the menton deviation was approximately 3 mm lower when estimated using the ANS-associated MSP than that using upper facial MSP. Conclusions: The choice of MSP can significantly affect treatment outcomes while diagnosing patients with asymmetry. Therefore, care should be taken when selecting MSP in clinical practice.

Cone beam형 전산화단층촬영법을 이용한 하악과두의 골변화에 관한 연구 (Bone change of mandibular condyle using cone beam computed tomography)

  • 이지운;김형섭;송주섭;김경아;고광준
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.139-147
    • /
    • 2007
  • Purpose: To assess bone changes of mandibular condyle using cone beam computed tomography (CBCT) in temporomandibular disorder (TMD) patients. Materials and Methods: 314 temporomandibular joints (TMJs) images of 163 TMD patients were examined at the Department of Oral and Maxillofacial Radiology, Chonbuk National University. The images were obtained by PSR9000N (Asahi Roentgen Co., Japan) and reconstructed by using Asahivision software (Asahi Roentgen Co., Japan). The CBCT images were examined three times with four weeks interval by three radiologists. Bone changes of mandibular condyle such as flattening, sclerosis, erosion and osteophyte formation were observed in sagittal, axial, coronal and 3 dimensional images of the mandibular condyle. The statistical analysis was performed using SPSS 12.0. Intra- and interobserver agreement were performed by 3 radiologists without the knowledge of clinical information. Results: Osteophyte (2.9%) was found more frequently on anterior surface of the mandibular condyle. Erosion (31.8%) was found more frequently on anterior and medial surfaces of the mandibular condyle. The intraobserver agreement was good to excellent (k=0.78-0.84), but interobserver agreement was fair (k=0.45). Conclusion: CBCT can provide high qualified images of bone changes of the TMJ with axial, coronal and 3 dimensional images.

  • PDF

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가 (Characterization of Cone-beam Computed Tomography System for Small Animal)

  • 강형근;천권수
    • 한국방사선학회논문지
    • /
    • 제4권1호
    • /
    • pp.19-24
    • /
    • 2010
  • 콘빔형 소동물용 CT 장치는 바이오-의료분야의 기초 실험에 활발히 응용되고 있다. $10{\mu}m$의 직경을 가진 텅스텐 와이어(wire)와 물 팬텀을 이용하여 비교적 간단한 방법으로 소동물용 CT 장치를 평가할 수 있는 방법을 제시하였다. X선 튜브가 안정적으로 장시간 운전 가능한 조건에서 $1^{\circ}$ 간격으로 360개의 투영영상을 획득하고, 영상재구성을 통하여 슬라이스 영상 및 3차원 영상을 얻었다. 콘빔형 소동물용 CT 장치는 배율 1.07배 위치에서 13.78lp/mm(공간해상도 $36.2{\mu}m$)를 나타내었고, 80kV의 관전압에서 CNR 10.33 및 S/N 5.87을 보였다.