• Title/Summary/Keyword: Three-axial

Search Result 1,417, Processing Time 0.025 seconds

Effect of Flow Angles at Nozzle and Solidities on a Partial Admitted Small Axial-Type Turbine (부분분사 소형 축류형터빈에서 현절비와 노즐유동각이 성능에 미치는 연구)

  • Cho, Chong-Hyun;Ahn, Kook-Young;Cho, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.6
    • /
    • pp.21-29
    • /
    • 2008
  • Performance characteristics on a partially admitted small axial-type turbine are experimentally studied with changing design parameters, such as exit flow angles at the nozzle and solidities at the rotor. The tested turbine consists of a single-stage and its mean radius is 35 mm. In this experiment, three different solidities and four different nozzle flow angles are applied to find the optimal design parameter. For a comparison of the turbine performance, the net specific output powers are evaluated. For a 3.4% partial admission rate, the best performance is obtained when the rotor solidity is at 2.18, which is increased to 74% compared to the solidity at full admission.

Effect of Blade Loading on the Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan (블레이드 하중이 축류형 팬에서의 팁 누설 유동구조에 미치는 영향)

  • 이공희;명환주;백제현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.294-304
    • /
    • 2003
  • An experimental analysis using three-dimensional laser Doppler velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

A Study on the Effect of Sweep Angle of Axial Fan on Its Noise (축류송풍기의 스윕각이 소음에 미치는 영향에 대한 연구)

  • Choi, Jae-Ho;Kim, Kwang-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.365-370
    • /
    • 2000
  • A computational study on the effect of sweep angle of axial fan on its noise is performed in the present paper. The forward swept axial fan was designed by numerical optimization method incorporated with three dimensional flow analysis. The objective function was defined by the ratio of generation rate of turbulent kinetic energy to pressure head. And, two variables related with sweep angle distribution are used for design variables. The swept fan has better performance characteristics and noise level. The experimental result shows that spectrums of no-sweet and swept fans have differences in the blade passage frequency, especially in the broadband. And the overall noise level of swept fan is lower 10dB(A) than that of no-sweep fan. For the comparison of flow fields between no-sweep fan and swept fan, CFX-TASCflow computational fluid dynamics software is used. Standard k-${\varepsilon}$ model is used for the turbulence model. Distributions of pressure and turbulent kinetic energy distributions are compared in order to find what happen in the low-noise swept fan.

  • PDF

Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan (전향 축류형 홴에서의 익단 누설 유동 구조)

  • Lee, Gong-Hee;Myung, Hwan-Joo;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.883-892
    • /
    • 2003
  • The experiment using three-dimensional laser Dopperr velocimetery (LDV) measurements and the computation using the Reynolds stress model of the commercial code, FLUENT, were conducted to give a clear understanding on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition. The tip leakage vortex was generated near the position of the minimum wall static pressure, which was located at approximately 12% chord downstream from the leading edge of blade suction side, and developed along the centerline of the pressure trough within the blade passages. A reverse flow between the blade tip region and the casing, induced by tip leakage vortex, acted as a blockage on the through-flow. As a result, high momentum flux was observed below the tip leakage vortex. As the tip leakage vortex proceeded to the aft part of the blade passage, the strength of tip leakage vortex decreased due to the strong interaction with the through-flow and casing boundary layer, and the diffusion of tip leakage vortex caused by high turbulence. In comparison with LDV measurement data, the computed results predicted the complex viscous flow patterns inside the tip region, including the locus of tip leakage vortex center, in a reliable level.

Characteristics of Spray from Pressure-Swirl Nozzle with Different Liquid Properties and Nozzle Geometries (액체의 물성치와 노즐의 형상 변화에 따른 압력스월 노즐의 분무 특성)

  • Choe, Yun-Cheol;Jeong, Ji-Won;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1813-1820
    • /
    • 2001
  • The purpose of this study was to investigate the significant characteristics in atomization process of industrial etching spray fur the design or Precise pressure-swirl nozzles. The experiment was carried out with different viscosities and densities of the liquid. The macro characteristics of liquid spray, such as the spray angle and breakup process were captured by PMAS and the micro characteristics of liquid spray. such as droplet size and velocity measurements were obtained by PDA. The droplet axial and radial velocity and SMD were measured along axial and radial direction. The RMS of two velocities was measured along radial direction. It was found that the fluid with higher kinematic viscosity resulted in the larger SMD and the lower mean droplet velocity. And we could divide breakup processes into three regions that is atomization, non-dilution and dilution one in spray of pressure-swirl nozzle. The radial as well as axial velocity of droplet played an important role in the atomization process of higher kinematic viscosity fluid.

Tracking Control of Servo System using Fuzzy Logic Cross Coupled Controller (퍼지 논리형 상호결합 제어기를 이용한 서보 시스템의 추적제어)

  • 신두진;허욱열
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.8
    • /
    • pp.361-366
    • /
    • 2001
  • This thesis proposes a fuzzy logic cross coupled controller for a multi axis servo system. The overall control system consists of three elements: the axial position controller, the speed controller, and a fuzzy logic cross coupled controller. In conventional multi axis servo system, the motion of each axis is controlled independently without regard to the motion of other axes, in which the contour error, defined as the shortest distance between the desired and actual contours is compensated only by the position error of each axis. This decoupled control approach may result in degraded contouring performance due to such factors as mismatch of axial dynamics and axial loop gains. In practice, such systems contain many uncertainties, Therefore, the multi axis servo system must receive and evaluate the motion of all axes for a better contouring accuracy. Cross coupled controller utilizes all axis position error information simultaneously to produce accurate contours. However the existing cross coupled controllers cannot overcome friction, backlash and parameter variation. Also, since it is difficult to obtain an accurate mathematical model of multi axis system, here we investigate a fuzzy logic cross coupled controller method. Some simulations and experimental results are presented to illustrate the performance of the proposed controller.

  • PDF

Numerical Study on the Clocking Effect in a 1.5 Stage Axial Turbine (1.5단 축류 터빈에서의 Clocking 효과에 관한 수치적 연구)

  • Park, Jong-Il;Choi, Min-Suk;Baek, Je-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.473-480
    • /
    • 2005
  • Clocking effects of a stator on the performance and internal flow in an UTRC 1.5 stage axial turbine are investigated using a three-dimensional unsteady flow simulation. Six relative positions of two rows of stator are investigated by positioning the second stator being clocked in a step of 1/6 pitch. The relative efficiency benefit of about 1% is obtained depending on the clocking positions. However, internal flows have some different characteristics from that in the previous study at the best and worst efficiency positions, since be first stator wake is mixed out with the rotor wake before arriving at the leading edge of the second stator. Instead of the first stator wake, it is found that the wake interaction of the first stator and rotor has a important role on a relative efficiency variation at each clocking position. The time-averaged local efficiency along the span at the maximum efficiency is more uniform than that at the minimum efficiency. That is, the spanwise efficiency distribution at the minimum efficiency has larger values in mid-span but smaller values near the hub and casing in comparison to those at the maximum efficiency. Moreover, the difference between maximum and minimum instantaneous efficiencies during one period is found to be smaller at the maximum efficiency than at the minimum efficiency.

  • PDF

Optimum Shape Design of the Spring to Improve the Loose-proof Performance of the Lock Nut (로크 너트의 풀림 방지 성능 향상을 위한 스프링의 최적 형상 설계)

  • Song, Hyun-Seok;Chung, Won-Sun;Jung, Do-Hyun;Seo, Young-Kyo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • The combination of a bolt and nut is the element most widely used for connecting machines and structures. When a load is repetitively applied in the direction right angle to the bolt axis after the bolt and nut is fastened, the nut gradually becomes loose. To solve this problem, in this study, a new type of the loose-proof nut, called a lock nut, is developed. The lock nut is equipped with a spring, and the spring increases the axial force of the bolt. Then, the connection force between the bolt and nut is also augmented. Three dimensional finite element models for the bolt and spring are generated, and the change of the axial force of the bolt while the bolt is being inserted into the spring is analyzed using MSC/Marc, a commercial finite element program. Finally, the optimum shape of the spring is found according to the response surface analysis methodology. The optimization result is verified by comparing the variation of the axial force of the bolt when the bolt is inserted to the initial and optimized spring.

A Study on the Adduction and Abduction Measurement of Children with Spastic Cerebral Palsy for the Development of Multi-axial Lower Extremity Orthosis (경직성 뇌성마비 소아의 다축 하지 보조기 설계를 위한 내.외전력 측정)

  • 김동진;이영신;김봉옥;양신승;박인식
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.443-446
    • /
    • 2003
  • In the present study. the design of multi-axial lower extremity orthosis was presented with adduction and abduction force data which were measured from three children with cerebral palsy and a normal child. The measurements of adduction and abduction forces were conducted in standing and wolking condition. Adduction and abduction forces were measured by strain gages which were attached on the lateral uprights of lower extremity orthoses. In the standing condition. addcution force of childrens was distributed from 0.11 kgf to 0.26 kgf. During the walking condition. adduction force was reached to 1.56 kgf and abduction force was reached to 1.52 kgf.

Optimum Global Failure Prediction Model of Inconel 600 Thin Plate with Two Parallel Through-Wall Cracks

  • Moon Seong In;Kim Young Jin;Lee Jin Ho;Song Myung Ho;Choi Young Hwan
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.316-326
    • /
    • 2004
  • The $40\%$ of wall criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In a previous study, a total number of 9 failure models were proposed to estimate the local failure of the ligament between cracks, and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however known that parallel axial cracks are more frequently detected than collinear axial cracks during an in-service inspection. The objective of this study is to determine the plastic collapse model that can be applied to steam generator tubes containing two parallel axial through-wall cracks. Three previously proposed local failure models were selected as the candidates. Subsequently, the interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed to determine the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a COD base model was selected as an optimum model.