• Title/Summary/Keyword: Three-Dimension CAD

Search Result 23, Processing Time 0.025 seconds

A Study on the 3D Injection Mold Design Using CATIA API (CATIA API를 이용한 사출 금형의 3차원 설계에 관한 연구)

  • 박주삼;김재현;박정환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.115-125
    • /
    • 2003
  • The design methodology of plastic injection molding die has been gradually moved from two-dimensional line drawings to three-dimensional solid models. The 3D design gives many benefits, a few of which are: ease of design change, data associativity from concept design to final assembly. In the paper represented is the implementation of a program which automatically generates 3D mold-bases and cooling-lines, conforming to given geometric constraints. It utilized a commercial CAD software and the related API(application program interface) libraries. We constructed a DB(database) of typical mold-bases assembled from standard parts, from which the geometry (position & dimension) of a mold-base and composed parts can be automatical]y determined by a few key parameters. Also we classified cooling lines into several typical types and constructed a DB, from which the position of cooling lines is automatically determined. The research is expected not only to simplify construction of a 3D mold-base model including cooling lines but also to reduce design efforts, by way of databases and automatized determination of geometric dimensions.

Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data- (유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로-)

  • Han, Chohee;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.2
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

A Study on Weave Design of Supplementary Warp using Computer-Aided Weaving System (CAW(Computer-Aided Weaving) 시스템을 활용한 Supplementary Warp의 직조디자인 연구)

  • Song, Ha-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.3
    • /
    • pp.43-55
    • /
    • 2010
  • The major advantages to use CAD System are that it reduce time and effort to manufacture products, and also can demonstrate the condition of the final product prior to the actual manufacturing process of the selected design using the simulation programs in CAD system. Specially in weave design, for use as Computer-Aided Weaving system, the complicated Dobby weave can figured out easily through calculating the complex weave plans of multi shafts. As to one of dobby weave structures, Supplementary warp is the warp threads which are in addition to the regular warps of the woven fabrics, and used for decorating the band or expressing some patterns. The purpose of this study is to research the weave design of Supplementary warp using Computer-Aided Weaving system, which is dobby weave design program of Weave Point. For performing this design study, it was researched the classified woven fabrics depending upon weaving processing, Computer-Aided Weaving system, and the characteristic of Supplementary warp fabrics. On the basis of the theoretical research, Supplementary warp was worked for the 24-shafts AVL computer dobby loom that applied to the various patterned images. The design work was done by Weave Point program of dobby weave, and simulated to fabrics before woven into the computer dobby loom. To see the visual images of fashion items, these simulated bobby fabrics were processed by three-dimension modeling through YoungWoo CNI CAD system. All the patterns of the Supplementary warp in this study could be applied for decorating the fashion clothing and accessories.

  • PDF

Application of Computer Aided Blank Design System for Motor Frame Die, Automobile (자동차 모터 프레임 금형에서 블랭크 설계 자동화 시스템의 적용)

  • 박동환;박상봉;강성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.753-756
    • /
    • 2000
  • The accumulated know-how and trial-and-error procedures are known as the best ways to determine blank shape and dimensions. One of the most important steps to determine the blank shape and dimensions in deep drawing process is to calculate the surface area of the product. In general, the surface area of products is calculated by mathematical or 3-D modeling methods. A blank design system is constructed for elliptical deep drawing products to recognize the geometry of the product in the long side and short side by drafting in another two layers on AutoCAD software. This system consists of input geometry recognition module, 3-D modeling module and blank design module, respectively. Blank dimension of three types is determined by the same area, which was acquired in 3-D modeling module. The suitability of this system is verified by applying to a real deep drawing product.

  • PDF

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

A Study on the Utilization of Digital Design by Three Dimensional Modeling (3차원 모델링을 이용한 디지털 디자인의 활용에 관한 연구)

  • Han, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.447-456
    • /
    • 2012
  • In space design or form design step, recognized necessity of digital design practical use. Also, deduced systematized analysis method that can use various function of CAD system actively. These method can promote the practical use because third dimensional digital design escapes plan and design process in concept that get presentation result after is completed, establishes role of effective and systematic digital design at planning and design of space or form. This uses by a design tool that ease designer's judgment and space and form analysis in architectural planning and design process that third dimension digital design is not part by a simplicity design tool. Share and takes advantage of digital design process method that is deduced in this study, need continuance of connection study for more effective and systematic digital design methodology deduction. Need public ownership of teaching material development and teaching method that can deliver extended third dimension digital design process.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

A Robotic Milking Manipulator for Teat-cup Attachment Modules (착유컵 자동 착탈을 위한 매니퓰레이터 개발)

  • Lee, D. W.;Kim, W.;Kim, H. T.;Kim, D. W.;Choi, D. Y.;Han, J. D.;Kwon, D. J.;Lee, S. K.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.163-168
    • /
    • 2001
  • A manipulator for test-cup attachment modules, which was a part of a robot milking system, was developed to reduce cost and labor for cow milking processing. A Cartesian coordinate manipulator was designed for the milking process, because it was quite flexible and can be constructed more economically than any other configuration. The manipulator was made use of DC motors, screws for power transmission, a RS422 interface system for the transmission of coordinate values and a one-chip microprocessor, 89C52. Performance tests of the manipulator were conducted to measure experimentally the precision of all axes. Some of the results are as follows. 1. The Cartesian coordinate manipulator was designed and built. Dimension of the three perpendicular axes (X, Y, and Z) and one arm’s axis(W) to pick up and transfer the modules were 700㎜$\times$450㎜$\times$550㎜$\times$650㎜. The arm’s axis moved the teat-cup attachment module, which attached four teat-cup to four teats, detached four teat-cup from four teats, was designed and manufactured by using CAD, CAM and CNC. 3. After 10 replications of exercising the manipulator, mean precision values(positioning error) of X, Y, Z axes wee 0.48㎜, 0.20㎜, 0.19㎜, respectively. Therefore, we conclude the axes to have a precision better than 0.5㎜, had no problem to operate correctly the milking manipulator.

  • PDF