• 제목/요약/키워드: Three-Dimension

Search Result 1,443, Processing Time 0.025 seconds

Physiological Responses of One-year-old Zelkova serrata Makino Seedlings to Ozone in Open-top Chamber (Open-top chamber 내(內)에서 오존에 폭로(暴露)시킨 1년생(年生) 느티나무(Zelkova serrata Makino) 묘목(苗木)의 생리적(生理的) 반응(反應)에 관(關)한 연구(硏究))

  • Kim, Hyun Seok;Lee, Kyung Joon
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.424-431
    • /
    • 1995
  • This study was conducted to evaluate resistance and physiological responses of Zelkova serrata Makino seedlings to ozone in open-top chamber. One-year-old seedlings of Zelkova serrata were planted in pots in April and grown in greenhouse until August. The plants were transferred into two out-door open-top chambers with a dimension of 2.0 m in diameter and 2.0 m in height. First chamber served as a control and was supplied with ambient air. Ozone was added to the second chamber for 5 hours per day(10.00 AM-15.00 PM) for 23 consecutive days at 0.1 ppm. Each chamber housed 70 pots. Every two, three or five days after initiation of exposure, ten pots were randomly removed from the chamber and determined for the contents of chlorophyll a, b, total chlorophyll and ${\beta}$-carotene in the leaves. Photosynthesis and dark respiration were estimated by measuring $CO_2$ absorption in a gas exchange chamber and oxygen absorption by oxygen monitoring system, respectively. Superoxide dismutase(SOD) activity in the leaves was assayed by a xanthine oxidase method. First visible injury of translucent(water-soaked looking) spots appeared on the leaves 14 days after the initial exposure, and ozone accelerated senescence of old leaves. Contents of chlorophyll a and b decreased by 17%, and 31%, respectively, in ozone treatment two days after exposure. The decrease in chlorophyll b was greater than that of chlorophyll a. Content of ${\beta}$-carotene in ozone treatment decreased by 25% two days after initiation of exposure, but the reduction was recovered with time. Photosynthesis decreased by 45%, and the respiration increased by 28% in the ozone treatment. SOD activity started to increase 4 days after beginning of exposure and increased by 285% 7 days after exposure, and decreased to the level below the control treatment with the advancement of the visible injury.

  • PDF

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Fracture Pattern and Physical Property of the Granodiorite for Stone Resources in the Nangsan Area (낭산일대에 분포하는 화강섬록암 암석자원의 열극체계 및 물리적 특성)

  • Yun, Hyun-Soo;Hong, Sei-Sun;Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.144-161
    • /
    • 2007
  • The studied Nangsan area is widely covered by the Jurassic biotite granodiorite, which is mainly light grey in color and medium-grained in texture. Results of the regional fracture pattern analysis for the granodiorite body are as follows. Strike directions of fractures show three dominant sets in terms of frequency order. The sets are in an order of a (1) $N80^{\circ}{\sim}90^{\circ}E$ (1st-order)>(2) $N70^{\circ}{\sim}80^{\circ}E$ (2nd-order)>(3) $NS{\sim}N10^{\circ}E$ (3rd-order). Spacings of the fractures are mostly predominant in less than 200 cm. Therefore, the granodiorite of the area has more potential for non-dimensional stones than dimension ones. And orientations of vertical quarrying planes can be also divided into two groups in terms of frequency $N14^{\circ}W{\sim}N16^{\circ}E$ (1st-order) and (2) $N78^{\circ}E{\sim}N88^{\circ}E$ (2nd-order). The orientations of the two groups are more or less different from those of the regional fracture patterns. These can be mainly attributed to the preferred orientations of microcrack developed in the quarries. Of physical properties, specific gravity, absorption ratio, porosity, compressive strength, tensile strength and abrasive hardness are 2.65, 0.28%, 0.73%, $1,628kg/cm^2,\;100kg/cm^2$ and 31, respectively. Contrary to the porosity, both granites of the Nangsan and Sogrisan areas show almost similar values of the abrasive hardness. These can be explained by the differences of Qz+Af modes, which can be regarded as an index for abrasive resistance. Meanwhile, it is anticipated that comprehensive understanding of the orientations of vertical quarrying planes and characteristics of various physical properties will be utilized as an important information for stone resources.

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

The Pain Behavior of Patients with Joint Pain (관절통환자의 통증정도와 통증연관 행위에 관한 연구)

  • 이은옥;한윤복;김순자;이선옥;김달숙;김조자;김광주;김주희;박점희
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.2
    • /
    • pp.197-210
    • /
    • 1988
  • The purposes of this study were : 1) to assess the level of pain and to identity the varieties and the degree of pain-related behavior, 2) to measure the level of correlation between the level of pain and the degree of pain- related behavior, 3) to test the correlation between the Korean Pain Rating Scale (KPRS) and Graphic Rating Scale(GRS), and 4) to gather data relevant to the Socio-demographic status of the subjects. The level of pain was measured by KPRS and GRS developed by the researchers. The KPRS consists of three dimensions ; the sensory, the affective and the miscellaneous and the GRS of two separate scales ; the intensity scale and the unpleasantness scale. Of the 2, 025 who had visited orthopedic and neurosurgical out-patients department of 11 university hospitals in various districts of Korea with the episode of Joint pain, 405 subjects were self-selected by responding to the data gathering tools and questionaires mailed. The results are summaried as follows : 1. Maale(217, 53.6%) exceeded female patients(188, 46.4%) in number and the onset of joint pain was more prevalent in the age groups of the 20s and the 30s. 160(39.5%) had been hospitalized for the treatment of, and 87(21.5%) had retired because of the joint pain. 2. Mean pain score measured by KPRS was 128.31 (range; 0-1.344.8) ; mean sensory score was 43.23(range ; 0-645.88%), mean affective score was 46.09(range ; 0- 356.72), and mean miscellaneous score was 39.99(range ; 0-341.68). Mean pain scores measured by GRS were ; sensory intensity score ; 109.1(range ; 0-200) and distress score ; 99.1 (range ; 0-200). 3. The prevalent sites of joint pain revealed to be the right knee joint(203; 50.1%), left knee joint(181(44.7%), left ilium(147, 36.3%), lumbar region (106; 26.2%), hip joint(92; 22.7%) and the ankle(84; 20.7%). 4. The average sleep hour was 6.8hours per day and the average rest hour during the day hours was 3.3hours (range 0-20). 5. The average duration of suffering from joint pain was 49.1 months. 6. Most of the subjects(298; 73.6%) used some sorts of pain relieving practices ; the most prevalent pain relieving practice was the compliance with the physician prescribed treatments(34.4%). 7. The level of discomfort in carrying out the ADL(activities of daily living was 101.16(38.83) and the level of needs for aid in carrying out the ADL was 76.62(31.79). 8. The interrelation between KPRS total score and GRS sensory intensity score(.4438), as well as that of GRS distress score(r=.4446) were not highly correlated, however, sensory and affective dimension within KPRS (.7547) and pain intensity and distress score of GRS(.6975) revealed moderate intercorrelation. 9. Pain-related behaviors such as discomfort in carrying out ADL, the need for aids in carrying out ADL, frequency of pain relieving practices, varieties of pain sites and length of rest hours during the day hours revealed to be highly correlated with the level of pain measured by KPRS, GRS sensory intensity scale and GRS distress scale. The following are recommended ; 1. Test for the correlation of KPRS total score and the summated score of GRS ; sensory intensity and distress scores. 2. Possibilities of utilization of the pain-related behaviors which revealed high correlation as indirect assessment tool for measuring the level of pain.

  • PDF

A Study on the Perceived Stress Level of Mothers in the Neonatal Intensive Care Unit Patients (신생아 중환자실에 입원한 환아 어머니의 스트레스)

  • Kim Tae Im
    • Child Health Nursing Research
    • /
    • v.6 no.2
    • /
    • pp.224-239
    • /
    • 2000
  • This descriptive study was conducted to understand the contents and degree of parental stress level in the NICU patients, and to give a baseline data in developing nursing intervention program. Subjects were the 62 mother of hospitalized newborn in NICU of 1 University Hospital in Taejon City from May 1st, 1999 to November 30th, 1999, who agreed to take part in this study. The instrument used in this study were Parental Stressor Scales : NICU(PSS:NICU) developed by Miles et al. and validated by 3 NICU practitioners and 3 child health nursing faculties. The questionnaire has 4 dimensions and 45 items; sight and sounds of NICU(5 items), babies' appearance and behavior(19 items), parental role alteration and relationship with their baby(10 items), communication with health team(11 items). The questionnaire asks parents to rate each item on a five-point Likert type scale that ranges from (1) to (5). Total scores representing overall stress from the NICU environment are calculated by summing response to each item. A high score indicates high stress. A subscale score is calculated by summing the responses to each item in the subscale. Cronbach's α coefficients were .93. The data was analyzed as average, Frequency, Standard deviation, t-test, ANOVA, Pearson correlation coefficient by use of SPSS/PC+. The results of this study is summarized as follows ; 1. The total perceived stress level score of mothers was slightly high(3.6±.7). The highest scored dimension was 'appearance and behavior of the baby'(3.9±1.5), and next were 'relationship with their baby and parental role change'(3.5±1.4), 'communication with health team'(3.4±.9), 'sight and sounds of NICU'(3.2±.8). 2. Two variables were statistically significant with PSS:NICU total scale ; mother's perceived severity of the baby's condition (r=.482, P=.002) and mother's religious attendance(t=2.83, P=.01). The more the mother perceive their baby's condition severe, the higher the total stress score. There were high stress score noted in the mother of no religious attendance. 3. Four variables were statistically significant with NICU environment subscale ; mother's educational background(F=3.45, P=.04), religious attendance(t=2.28, P=.04), sex of the baby(t=2.83, P=.01) and NICU patients' hospital day(r=.359, P=.004). That is mother with high educational background and girl baby were high NICU environment subscale score. 4. Four variables were statistically significant with appearance and behavior of the baby subscale ; when first saw baby(F=3.52, P=.04), incubator care(t=2.83, P=.01), mother's perceived severity of the baby's condition(r=.303, P=.017), number of NICU visit(r=.441, P=.002). That is, seeing the baby first in the NICU and recieved incubator care was very stressful. Also, the more the mother perceive their baby's condition severe and more NICU visit, the higher the appearance and behavior of the baby subscale stress score. 5. Four variables were statistically significant with relationship with their baby and parental role change subscale ; when first saw baby(F=3.37, P=.04), sex of the baby(t=2.36, P=.03), incubator care(t=5.60, P=.00), mother's perceived severity of the baby's condition(r=.401, P=.001). That is, seeing the baby first in the NICU and girl baby was very stressful. Also, the more the mother perceive their baby's condition severe, the higher the relationship with their baby and parental role change subscale stress score. 6. Three variables were statistically significant with communication with health team subscale ; mother's educational background (F=3.63, P=.04), incubator care(t=4.24, P=.00), gestational age(r=-.394, P=.047), and birth weight(r=-.460, P=.004). That is, mother with high educational background and receiving incubator care were high communication with health team subscale score. Also, the shorter the gestational age and smaller the baby's birth weight, the higher the communication with health team subscale score. In conclusion, information about physical environment of NICU, the mother's perceived severity of baby's illness state, maternal role change related variables and the knowledge of characteristics of NICU patients must be included in nursing intervention program of mother's of NICU patients in reducing the maternal stress and anxiety level.

  • PDF

COMPARISON FOR THE RETENTION OF CASTING CROWN AND CEMENT THICKNESS FOLLOWING VARIOUS CEMENTS (수종의 세멘트에 따른 주조금관의 유지력 및 세멘트 두께의 비교)

  • Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of various cements on the retention of casting crown and the cement film thickness. To evaluate the retention of crown, thirty maxillary premolars were used and prepared to largely same dimension. According to the routine method, Non-precious metal crowns were made. The teeth and the metal crowns were divided into three groups and cemented under 5kg static pressure. Group I was composed of 10 teeth and 10 metal crowns and was cemented with zinc phohsphste cement. Group II was composed of 10 teeth and 10 metal crowns and was cemented with Panavia-EX cement. Group III was composed of 10 teeth and 10 metal crowns and was cemented with All-Bond & composite resin cement. After 5 days, the cemented specimens were mounted and the failure loads were measured by an Instron Universal Testing Machine. To evaluate the cement film thickness. 5 metal teeth and 5metal crowns from a prepared maxillary premolar were made. Two marks were flawed on the margin part of each surface at 4-surfaces of each specimen(one mark : crown, the other : metal tooth) and were measured the width with SEM photograph(80 sheets) before and after cementation(Panavia-EX, All-Bond cement, & ZPC) was made. Differences of the widths of marks between before and after were measured, and differences from 4-surfaces of a specimen cemented with a cement were measured and calculated. The results were as follows ; 1. There was a statistically significant difference between the failure loads of group III and the others(p<0.05). 2. There was a statistically significant difference between the cement film thickness of group III and the others(p<0.05).

  • PDF

Development of Rain Shelter for Chinese Cabbage Rainproof Cultivation (배추재배용 비가림하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2014
  • This study was carried out to develop rain shelter which can make an appropriate size and environment for Chinese cabbage rainproof cultivation. Fifty three farms with chinese cabbage rainproof cultivation system have been investigated to set up width and height of rain shelter. Mostly the width of 6m was desired for rain shelter and the height of 1.6m for their eaves, so these values were chosen as the dimensions for rain shelter. After an analysis of their structural safety and installation costs by the specifications of the rafter pipe, Ø$25.4{\times}1.5t$ and 90cm have been set as the size of rafter that such size costs the least. This size is stable with $27m{\cdot}s^{-1}$ of wind velocity and 17cm of snow depth. Therefore it is difficult to apply this dimension to area with higher climate load. In order to sort out such problem, the rain shelter has been designed to avoid damage on frame by opening plastic film to the ridge. Once greenhouse band is loosen by turning the manual switch at the both sides of rain shelter and open button of controller is pushed then switch motor rises up along the guide pipe and plastic film is opened to the ridge. Chinese cabbage can be damaged by insects if rain shelter is opened completely as revealed a field. To prevent this, farmers can install an insect-proof net. Further, the greenhouse can be damaged by typhoon while growing Chinese cabbage therefore the effect of an insect-proof net on structural safety has been analyzed. And then structural safety has been analyzed through using flow-structure interaction method at the wind condition of $40m{\cdot}s^{-1}$. And it assumed that wind applied perpendicular to side of the rain shelter which was covered by insect-proof net. The results indicated that plastic film was directly affected by wind therefore high pressure occurred on the surface. But wind load on insect-proof net was smaller than on plastic film and pressure distribution was also uniform. The results of structural analysis by applying pressure data extracted from flow analysis indicated that the maximum stress occurred at the end of pipe which is the ground part and the value has been 54.6MPa. The allowable stress of pipe in the standard of structural safety must be 215 MPa or more therefore structural safety of this rain shelter is satisfied.

An Empirical Study on How the Moderating Effects of Individual Cultural Characteristics towards a Specific Target Affects User Experience: Based on the Survey Results of Four Types of Digital Device Users in the US, Germany, and Russia (특정 대상에 대한 개인 수준의 문화적 성향이 사용자 경험에 미치는 조절효과에 대한 실증적 연구: 미국, 독일, 러시아의 4개 디지털 기기 사용자를 대상으로)

  • Lee, In-Seong;Choi, Gi-Woong;Kim, So-Lyung;Lee, Ki-Ho;Kim, Jin-Woo
    • Asia pacific journal of information systems
    • /
    • v.19 no.1
    • /
    • pp.113-145
    • /
    • 2009
  • Recently, due to the globalization of the IT(Information Technology) market, devices and systems designed in one country are used in other countries as well. This phenomenon is becoming the key factor for increased interest on cross-cultural, or cross-national, research within the IT area. However, as the IT market is becoming bigger and more globalized, a great number of IT practitioners are having difficulty in designing and developing devices or systems which can provide optimal experience. This is because not only tangible factors such as language and a country's economic or industrial power affect the user experience of a certain device or system but also invisible and intangible factors as well. Among such invisible and intangible factors, the cultural characteristics of users from different countries may affect the user experience of certain devices or systems because cultural characteristics affect how they understand and interpret the devices or systems. In other words, when users evaluate the quality of overall user experience, the cultural characteristics of each user act as a perceptual lens that leads the user to focus on a certain elements of experience. Therefore, there is a need within the IT field to consider cultural characteristics when designing or developing certain devices or systems and plan a strategy for localization. In such an environment, existing IS studies identify the culture with the country, emphasize the importance of culture in a national level perspective, and hypothesize that users within the same country have same cultural characteristics. Under such assumptions, these studies focus on the moderating effects of cultural characteristics on a national level within a certain theoretical framework. This has already been suggested by cross-cultural studies conducted by scholars such as Hofstede(1980) in providing numerical research results and measurement items for cultural characteristics and using such results or items as they increase the efficiency of studies. However, such national level culture has its limitations in forecasting and explaining individual-level behaviors such as voluntary device or system usage. This is because individual cultural characteristics are the outcome of not only the national culture but also the culture of a race, company, local area, family, and other groups that are formulated through interaction within the group. Therefore, national or nationally dominant cultural characteristics may have its limitations in forecasting and explaining the cultural characteristics of an individual. Moreover, past studies in psychology suggest a possibility that there exist different cultural characteristics within a single individual depending on the subject being measured or its context. For example, in relation to individual vs. collective characteristics, which is one of the major cultural characteristics, an individual may show collectivistic characteristics when he or she is with family or friends but show individualistic characteristics in his or her workplace. Therefore, this study acknowledged such limitations of past studies and conducted a research within the framework of 'theoretically integrated model of user satisfaction and emotional attachment', which was developed through a former study, on how the effects of different experience elements on emotional attachment or user satisfaction are differentiated depending on the individual cultural characteristics related to a system or device usage. In order to do this, this study hypothesized the moderating effects of four cultural dimensions (uncertainty avoidance, individualism vs, collectivism, masculinity vs. femininity, and power distance) as suggested by Hofstede(1980) within the theoretically integrated model of emotional attachment and user satisfaction. Statistical tests were then implemented on these moderating effects through conducting surveys with users of four digital devices (mobile phone, MP3 player, LCD TV, and refrigerator) in three countries (US, Germany, and Russia). In order to explain and forecast the behavior of personal device or system users, individual cultural characteristics must be measured, and depending on the target device or system, measurements must be measured independently. Through this suggestion, this study hopes to provide new and useful perspectives for future IS research.

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF