• 제목/요약/키워드: Three phase PWM converter

검색결과 221건 처리시간 0.032초

급속 충전 시스템을 위한 DC-bias Pulse 충전 방식의 특성 연구 (The Characteristics Analysis of DC-Bias Pulse Method Charge for Fast Charging System)

  • 반충환;이영진;권완성;한동화;변병주;은종목;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.218-219
    • /
    • 2011
  • In this paper Li-polyer batteries, which are in use of EV recently, are used. The Li-polymer batteries have high density of energy and invulnerability of the fluids and explosion. It is confirmed that the DC-bias pulse mode/cc mode characteristics on charge by designing Fast-charging system designed in three phase PWM and full-bridge converter.

  • PDF

인터리브 방식 삼상 절연형 고효율 부스트 컨버터 (Three-Phase Interleaved Isolated High Efficiency Boost Converter)

  • 최정완;차한주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.910-911
    • /
    • 2008
  • 본 논문에서는 새로운 형태의 삼상 절연형 부스트 컨버터를 제안한다. 이 컨버터는 삼상구조의 특성에 의하여 큰 전력을 취급할 수 있고 전류 연속모드 작동에 의한 실효 전류 값이 작아져 전체적인 도통손실이 줄어든다. 또한, 각 입력 부스트 인덕터의 인터리브 동작으로 입력전류 리플이 작아짐과 더불어 실효 동작주파수가 증가함에 따라 필터부품의 크기도 줄어든다. 이러한 장점들은 연료전지의 전력변환기로서의 적용에 적합하다. 각 부스트 컨버터의 출력은 삼상 변압기를 통하여 합쳐지고 이 변압기를 통하여 입출력간 절연과 승압이 이루어진다. 전체 효율은 평균 96 %이며, 이는 도통손실의 감소와 능동클램프의 적용에 의한 스위칭 손실 감소의 결과로 판단된다. 제안된 컨버터와 삼상 PWM 스위칭 방식을 구간별로 해석하였고 시뮬레이션 하였다. 또한, 500 W 급 하드웨어로 구현 및 실험을 통하여 설계를 검증하고 그 결과를 분석을 하였다.

  • PDF

연료전지 자동차 전장전원용 고효율 양방향 3상 DC-DC 컨버터 (A High Efficiency Bidirectional Three-Phase DC-DC Converter for Auxiliary Power Supply of Fuel Cell Vehicles)

  • 윤창우;김형준;최세완;강호성;이현동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.209-212
    • /
    • 2008
  • 본 논문에서는 연료전지자동차의 저전압 배터리 충 방전을 위한 새로운 3상 양방향 DC-DC 컨버터를 제안한다. 12V 저전압측의 높은 전류정격 때문에 기존의 풀브리지 방식으로는 적절한 스위치의 선정이 어렵지만 제안한 3상의 전류분배로 스위치의 선정과 변압기의 제작이 용이하다. 그리고 제안한 변압기 결선으로 턴비가 작아져 누설인덕턴스가 작아진다. 또한 비대칭 PWM에 의한 모든 스위치의 ZVS 턴온과 저전압 측에서는 동기정류 방식을 적용하여 효율을 상승시켰다. 제안하는 컨버터의 동작원리를 기술하고 3.5kW 시작품을 제작하여 실험을 통해 본 방식의 타당성을 검증한다.

  • PDF

3상 매트릭스 컨버터의 고효율 변조방법 개발 및 실험 (Design and Implementation of high efficiency PWM modulation method for Three-phase Matrix Converter)

  • 임현주;차한주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.181-182
    • /
    • 2010
  • 매트릭스 컨버터는 출력 한 상에 대하여, 입력 3상이 교대로 연결되는 형태이다. 현재 사용하고 있는 개선된 벤츄리니 방법은 시비율과 캐리어를 사용하여 기존의 벤츄리니 구현 방법을 단순화 시켰지만 효율 측면에서만 본다면 불필요한 스위칭을 하고 있는 비효율적인 스위칭을 하고 있다. 이 논문에서는 기존 스위칭 패턴을 개선하여 스위칭 손실을 줄이고 효율을 개선하는 스위칭에 대해 제안해 본다. 기존의 비대칭 스위칭 패턴을 대칭된 스위칭 패턴으로 변화하여 특정한 섹터에서 추가적으로 발생되는 손실을 줄이고 해석적 손실의 정확도를 높일 수 있다. 제안된 방법에 대한 타당성을 입증하기 위해 실험을 수행하였다.

  • PDF

고속전철용 보조전원장치 시스템 조합시험 (Combined test of Power Supply System for Korean High Speed Train)

  • 조현욱;김연충;김태환;장경현;김철호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.619-625
    • /
    • 2008
  • Electrical Power supply System conditions of korea high speed train consists of main transformer, four AC-DC PWM converter of Auxiliary Block, Battery Charger in Power Car and Trailer Car, Trailer Inverter, Auxiliary inverter. Main transformer, at nominal voltage of 25kv supplied to secondary winding nominal output Voltage 383Vac, The Auxiliary block consists of AC-DC converters for generating 670VDC power, Auxiliary inverters for ventilation and air compressor, Trailer car inverter provide three phase power supplies at 440Vac for air conditioning and heating. The Battery charger Trailer and Power car supplies 72VDC all necessary equipment to energize the trainset equipment and suppy essential control. This Paper introduces the combined test results of the power supply system for korea high speed train. The main purpose of this combined test is to verify the performance of the power supply system that is designed to operate up to full load test.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

엘리베이터구동용 영구자석형 동기전동기의 속도제어에 관한 연구 (A Study on the Speed Control of PMSM for Elevator Drive)

  • 유재성;김이훈;최기준;윤관철;정무택;김연충;이상석;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.461-466
    • /
    • 2003
  • This paper presents the speed control of the surface-mounted permanent-magnet synchronous motors (SMPMSM) for the elevator drive. The elevator motor needs to be a compact and slim type. Essentially, the proposed scheme uses a vector control algorithm for a speed and torque control. This system is implemented using a high speed 32-bit DSP (TMS320C31-50), a high-integrated logic device FPGA (EPF10K10-Tl144-3) to design compactly and Inexpensively The proposed scheme is verified through digital simulation and experiments for a three-phase 13.3kW SMPMSM as a MRL(MachineRoomless) elevator motor ill the laboratory. Finally, experiment of the test tower was performed with a 48kW PWM converter-inverter system for a high- speed elevator .

  • PDF

인버터 부착형 농형 유도발전기의 계통고장특성 모의 (Grid faults characteristics simulation of inverter-fed induction generator)

  • 홍지태;권순만;김춘경;이종무;천종민;김홍주;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF

모델 예측 제어 기반 Cascaded H-bridge 컨버터의 균일한 손실, 스위칭 주파수, 전력 분배를 위한 알고리즘 (An Algorithm for Even Distribution of Loss, Switching Frequency, Power of Model Predictive Control Based Cascaded H-bridge Multilevel Converter)

  • 김이김;곽상신
    • 전력전자학회논문지
    • /
    • 제20권5호
    • /
    • pp.448-455
    • /
    • 2015
  • A model predictive control (MPC) method without individual PWM has been recently researched to simplify and improve the control flexibility of a multilevel inverter. However, the input power of each H-bridge cell and the switching frequency of switching devices are unbalanced because of the use of a restricted switching state in the MPC method. This paper proposes a control method for balancing the switching patterns and cell power supplied from each isolated dc source of a cascaded H-bridge inverter. The supplied dc power from isolated dc sources of each H-bridge cells is balanced with the proposed cell balancing method. In addition, the switching frequency of each switching device of the CHB inverter becomes equal. A simulation and experimental results are presented with nine-level and five-level three-phase CHB inverter to validate the proposed balancing method.