• Title/Summary/Keyword: Three dimensional finite element stress analysis

Search Result 617, Processing Time 0.035 seconds

Three Dimensional Finite Element Analysis for Powder Forging Process (분말단조 공정의 3차원 유한요소해석)

  • 김형섭
    • Journal of Powder Materials
    • /
    • v.3 no.2
    • /
    • pp.104-111
    • /
    • 1996
  • In order to obtain homogeneous and high quality products in powder compaction forging process, it is very important to control stress, strain, density and density distributions. Therefore, it is necessary to understand quantitatively the elasto-plastic deformation and densification behaviors of porous metals and metal powders. In this study, elasto-plastic finite element method using Lee-Kim's pressure dependent porous material yield function has been used for the analysis of three dimensional indenting process. The analysis predicts deformed geometry, stress, strain and density distribution and load. The calculated load is in good agreement with experimental one. The calculated results do not show axisymmetric distributions because of the edge effect. The core part which is in contact with the indentor and the outer diagonal edge part are in compressive stress states and the middle part is in tensile stress state. As a results, it can be concluded that three dimensional analysis is more realistic than axisymmetric assumption approach.

  • PDF

Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible

  • Heo, Kyung-Hoi;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.138-146
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of the splinted implant prosthesis in a reconstructed mandible using three-dimensional finite element analysis. MATERIALS AND METHODS. Three-dimensional finite element models were generated from a patient's computed tomography data. The patient had undergone partial resection of the mandible that covered the area from the left canine to the right condyle. The mandible was reconstructed using a fibula bone graft and dental implants. The left mandibular premolars and molars remained intact. Three types of models were created. The implant-supported prosthesis was splinted and segmented into two or three pieces. Each of these models was further subcategorized into two situations to compare the stress distribution around normal teeth and implants. Oblique loading of 300 N was applied on both sides of the mandible unilaterally. The maximum von Mises stress and displacement of the models were analyzed. RESULTS. The stress distribution of the natural mandible was more uniform than that of the reconstructed fibula. When the loading was applied to the implant prosthesis of reconstructed fibula, stress was concentrated at the cortical bone around the neck of the implants. The three-piece prosthesis model showed less uniform stress distribution compared to the others. Displacement of the components was positively correlated with the distance from areas of muscle attachment. The three-piece prosthesis model showed the greatest displacement. CONCLUSION. The splinted implant prosthesis showed a more favorable stress distribution and less displacement than the separated models in the reconstructed mandible.

Analysis of PSC Box Girder Anchorage Zone using FEM and 2D SUB-3D STM Approach (유한요소법 및 유사 3 차원 스트릿-타이 모델 방법을 이용한 PSC 박스거더 정착부의 해석)

  • Yun, Young-Mook;Kim, Seung-Eock;Oh, Jin-Woo;Park, Jung-Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.113-129
    • /
    • 2000
  • This study evaluates the behavior and strength of an anchorage zone of the prestressed concrete box girder bridge on the Kyungboo highway railroad using the 2D SUB-3D STM approach and a linear elastic finite element analysis. The 2D SUB-3D STM approach utilizes several two-dimensional sub strut-tie models that represent the compressive and tensile stress flows of each projected plane of the three-dimensional structural concrete in the selection of a three dimensional strut-tie model, evaluation of the effective strengths of the concrete struts, and verification of the geometric compatibility condition and bearing capacity of the critical nodal zones in the selected three-dimensional strut-tie model. The finite element analysis uses an 8-node brick element and the longitudinal prestressing force is considered as the equivalent nodal force. Analysis results show that the 2D SUB-3D STM approach and linear elastic finite element method can be effectively applied to the analysis and design of three-dimensional structural concrete including a prestressed concrete box girder anchorage zone.

  • PDF

THREE-DIMENSIONAL FINI6E ELEMENT ANALYSIS OF THE ENDOSSEOUS IMPLANT DESIGNS (삼차원 유한요소 해석에 의한 골내 임프란트의 구조에 관한 연구)

  • Hyun, Young-Keun;Kwon, Jong-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.181-210
    • /
    • 1997
  • The stress distribution generated in the surrounding bone was calculated and compared for various geometry of the dental implants by means of the finite element methods. The models were designed to represent the screw type endosseous implants(varing the size, shape, direction of the screw thread and the angle of the body) with supporting bone and the cylinder type endosseous implants(varing the lower portion-Round type, tapered type) with supporting bone. Static mean bite forces were applied 100N vertically and 25N horizontally on the center of the implant and three dimensional finite analysis was undertaken using software ANSYS 5.1 Version. The result demonstrated that different implant shape leads to significant variations in stress distribution in the bone. In the case of variation of the screw size, direction and shape the implant model with normally directional and triangular screw implied lower stress than with upper directional or lower directional and quadrangular screw but among models a different screw size, within a variation of 0.2mm there was no meaningful difference in maximum stress. In the case of variation of angle of body the straight implied lower stress than the tapered. As a result of analysis of cylinder type, the implants with larger radius of curvature of the round form and larger diameter of the tapered form implied lower stress.

  • PDF

Residual Stress Analysis of AISI 304 Surface Welding Plate by 3D Finite Element Method (3 차원 유한요소법을 이용한 AISI 304 표면용접평판의 잔류응력해석)

  • Lee, Kyoung-Soo;Kim, Tae-Ryong;Kim, Maan-Won;Park, Jai-Hak
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.390-395
    • /
    • 2008
  • This study is performed to understand three dimensional characteristics of weld residual stress for the surface weld on the stainless steel plate. AISI 304 plate with one path weld on the surface was used as a test specimen. Finite element analysis was done to analyze thermal transient and residual stress due to weld. The result of finite element analysis was validated by previous paper and measurement data. Among various techniques for residual stress measurement, instrumented ball indentation method was applied. The calculated residual stresses by finite element analysis showed good agreement with the measured results.

  • PDF

Three Dimensional Finite Element Analysis of Kimplant (Kimplant에 관한 3차원 유한요소 분석적 연구)

  • Kim, Woo-Uoung;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.9-17
    • /
    • 2004
  • In this study, the biomechanical characteristics of Kimplant were compared with that of Branemark implant by using three dimensional finite element analysis. Two finite element models were fabricated by inserting each implant into the bone model. The bone model was designed to have 18mm height, 13mm width and 15mm length. The size of each implant was planned to have 4mm width and 10mm length. A 200N force was applied on the center of abutment top in three directions - vertical, horizontal and oblique. After analyzing the stresses of fixture and surrounding bone, following results were obtained. 1. There was similar stress distribution between the two models. 2. The magnitude of maximum principal stress on the implant was similar between the two models but the location of maximum principal stress on the implant was different. 3. The magnitude and location of maximum principal stress on the surrounding bone was similar between the two models.

An Analysis for the Stress Redistribution around Tunnel Face Using Three-Dimensional Finite Element Method (3차원 유한요소법을 이용한 터널 막장 주위에서의 응력 재분배 해석에 관한 연구)

  • 문선경;이희근
    • Tunnel and Underground Space
    • /
    • v.5 no.2
    • /
    • pp.95-103
    • /
    • 1995
  • In this paper the stress redistribution around tunnel face was analyzed by using a three-dimensional finite element model. The effects of in-situ stress levels, excavation sequences, stiffness difference between the hard ground and the weak zone on the stress redistributions were considered. Displacement and stress changes at tunnel crown, side wall, and invert were investigated throughout the sequential excavation. To show ground response, percentage of the displacement and stress variations are used as a function of normalized distance that is between the face and monitoring section. Preceding displacements and stress variations were presented to be adopted in the two-dimensional tunnel analysis.

  • PDF

Fretting fatigue life prediction for Design and Maintenance of Automated Manufacturing System (생산자동화 시스템의 설계 및 정비를 위한 프레팅 피로수명 예측)

  • Kim, Jin-Kwang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.195-204
    • /
    • 2017
  • Predicting the failure life of automated manufacturing systems can reduce overall downtime, maintenance costs, and total plant operation costs. Therefore, there is a growing interest in fatigue failure mechanisms as the safety or service life assessment of manufacturing systems becomes an important issue. In particular, fretting fatigue is caused by repeated tangential stresses that are generated by friction during small amplitude oscillatory movements or sliding between two surfaces pressed together in intimate contact. Previous studies in fretting fatigue have observed size effects related to contact width such that a critical contact width exists where there is drastic change in the fretting fatigue life. However, most of them are the two-dimensional finite element analyses based on the plane strain assumption. The purpose of this study is to investigate the contact size effects on the three-dimensional finite element model of a finite width of a flat specimen and a cylindrical pad exposed to fretting fatigue. The contact size effects were analyzed by means of the stress and strain averages at the element integration points of three-dimensional finite element model. This study shows that the fretting fatigue life of manufacturing systems can be predicted by three-dimensional finite element analysis based on SWT critical plane model.

Analysis of Contact Stress with Partial Slip in Wheel-rail Rolling Contact (차륜-레일 구름접촉 시 슬립율에 따른 접촉응력의 변화 해석)

  • Lee, Dong-Hyong;Seo, Jung-Won;Kwon, Seok-Jin;Choi, Ha-Yong;Kim, Chul-Jae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.643-648
    • /
    • 2011
  • Fatigue crack in most rails take place by rolling contact between wheel and rail in railway industry. Therefore, it is critical to understand the rolling contact phenomena, especially for the three-dimensional situation. In this paper the steady-state rolling contact problem of KTX wheel and rail (UIC60) has been studied with three-dimensional finite element analysis. The variation of contact pressure and contact stresses on rolling contact surface were obtained using the finite element method. The three-dimensional distribution of contact stresses on the contact surface are investigated. Results show that the distribution of shear stress and contact stress (von Mises) on the contact surface varies rapidly as a result of the variation of stick-slip region. The contact stress at the leading edge is greater than at the trailing edge because of stick and slip phenomena.

  • PDF

Stress Distribution of Occlusal Loading Applied on Cervical Region Using 3D Finite Element Analysis (교합하중에 의한 치경부 응력분포의 3차원 유한요소해석)

  • Woo S.G.;Kim G.H.;Son K.;Park J.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.521-522
    • /
    • 2006
  • Occlusal loading is considered as the main factor of noncarious cervical lesions. The goal of this study is to identify stress distribution using three dimensional finite element analysis, when occlusal loading is applied on the cervical lesion of human tooth. A finite element model was constructed from micro-CT image and three kinds of static force(500 N) were assumed. In all cases stress concentrates on the same area in the cement-enamel junction. This finding is consistent with published experimental results.

  • PDF