• 제목/요약/키워드: Three canals

검색결과 173건 처리시간 0.029초

An Experimental Study of Non-Electrolysis Anti-Microfouling Technology Based on Bioelectric Effect

  • Young Wook Kim
    • 한국해양공학회지
    • /
    • 제37권4호
    • /
    • pp.172-179
    • /
    • 2023
  • Biofouling initiated by biofilm (slime) formation is a key challenge for practical ocean engineering and construction. This study evaluated a new anti-biofilm technology using bioelectricity. The anti-microfouling electrical technology is based on the principles of the bioelectric effect, known as the application of an electrostatic force for biofilm removal. Previously, the electricity was optimized below 0.82V to avoid electrolysis, which can prevent the production of biocides. A test boat comprised of microelectronics for electrical signal generation with electrodes for an anti-biofouling effect was developed. The tests were conducted in the West Sea of Korea (Wangsan Marina, Incheon) for three weeks. The surface biofouling was quantified. A significant reduction of fouling was observed under the bioelectric effect conditions, with approximately 30% enhanced prevention of fouling progress (P<0.05). This technology can be an alternative eco-friendly technique for anti-microfouling that can be applied for canals, vessels, and coastal infrastructure because it does not induce electrolysis.

Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis

  • Er, Ozgur;Kilic, Kerem;Esim, Emir;Aslan, Tugrul;Kilinc, Halil Ibrahim;Yildirim, Sahin
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.434-439
    • /
    • 2013
  • PURPOSE. The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS. A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An oblique force of 300 N was applied at an angle of $45^{\circ}$ to the occlusal plane and oriented toward the buccal side. von Mises stress was measured in three regions each for oval and circular fiber posts. RESULTS. FEM analysis showed that the von Mises stress of the circular fiber post (426.81 MPa) was greater than that of the oval fiber post (346.34 MPa). The maximum distribution of von Mises stress was in the luting agent in both groups. Additionally, von Mises stresses accumulated in the coronal third of root dentin, close to the post space in both groups. CONCLUSION. Oval fiber posts are preferable to circular fiber posts in oval-shaped canals given the stress distribution at the postdentin interface.

학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교 (Relative efficacy of three Ni-Ti file systems used by undergraduates)

  • 김현철;박정길;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.38-48
    • /
    • 2005
  • 이 연구의 목적은 Ni-Ti file을 사용한 경험이 없는 학생들이 세 종류 Ni-Ti file systems을 사용하였을 때 근관 형성 효율을 비교하는 것이다. Ni-Ti file의 사용 경험이 없는 부산대학교 치과대학 4학년 학생 50명이 세 종류의 Ni-Ti file system - $ProFile^{(R)}$ (PF : Dentsply Maillefer, Ballaigues, Switzerland), manual $ProTaper^{(R)}$ (MPT: Dentsply Maillefer, Ballaigues, Switzerland), rotary $ProTaper^{(R)}$ (RPT: Dentsply Maillefer, Ballaigues, Switzerland) -을 사용하여 각 system으로 하나의 근관씩, 모두 150개의 레진 블락 근관모형(Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland)을 형성하였다. 근관형성에 사용된 file의 파절이나 변형 및 근관형성 후 형태의 이상을 조사하고, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1mm, 3mm, 그리고 5mm 높이에서의 삭제된 근관의 폭경, 근관의 변위량, 그리고 중심변위율 등을 산출하고 통계학적 비교 분석을 하였다. 그리고 세 가지 systems에 관한 학생들의 주관적인 선호도를 조사하였다. 그 결과 졸업을 앞둔 치과대학 재학생들도 특별한 문제점 없이 세 가지 Ni-Ti file systems을 사용한 근관형성이 가능함을 확인하였다. 세 실험군을 비교하였을 때, 양적인 삭제 능력은 두 $ProTaper^{(R)}$ systems (manual and rotary)이 $ProFile^{(R)}$에 비해 우세하였지만, 근관의 변위는 두 $ProTaper^{(R)}$ systems에서 더 많이 유발되었다. 근관 중심 이동률 등의 질적 평가를 포함하여 학생들의 선호도를 종합적으로 고려할 때, 삭제 능력에 있어서는 rotary $ProTaper^{(R)}$가 더 효율적이지만 안전성을 고려하면 $ProFile^{(R)}$도 추천된다. 정규 교육과정에서 Ni-Ti file systems의 도입을 위해서 초심자와 관련한 더 많은 연구가 진행되어야 하겠다.

16S rDNA sequence에 대한 종특이성 primer를 이용한 중합효소연쇄반응증폭에 의한 Porphyromonas endodontalis의 동정에 관한 연구 (A STUDY ON THE IDENTIFICATION OF Porphyromonas endodontalis BY PCR USING SPECIES SPECIFIC PRIMERS FOR THE 16S rDNA)

  • 엄승희;임성삼;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.13-25
    • /
    • 1999
  • P. endodontalis which was known to be associated with the infected root canals and periapical lesions is very difficult to detect by culture methods or traditional methods. Detection of bacteria using polymerase chain reaction(PCR) for 16S ribosomal DNA(rDNA) is fast, simple, and accurate with relatively small amount of target cells. 16S rDNA consist of conserved regions those are same to all species, and variable regions which represent species specificity. The 16S rDNA sequences of P. endodontalis and P. gingivalis were aligned and two highly variable regions were selected as a pair of species specific oligonucleotide primers for P. endodontalis. And then the pair of primers for PCR amplification was synthesized to identify P. endodontalis. The sequences of the species specific primers for the 16S rDNA of P. endodontalis were as follows ; sense primer[endo1]: 5'-CTATATTCTTCTTTCTCCGCATGGAGGAGG-3' antisense primer[endo2]: 5'-GCATACCTTCGGTCTCCTCTAGCATAT-3' In this study, for the identification of P. endodontalis without culture from the mixed clinical samples, PCR was done with species specific primers for the 16S rDNA sequences of P. endodontalis. The results were as follows : 1. The species specificity of the primers for the 16S rDNA of P. endodntalis was determined by the PCR methods. About 490bp amplicon which was specific only for P. endodntalis was produced with P. endodontalis. No amplicon was produced by PCR with other strains similar to P. endodontalis. 2. The synthesized species specific primers reacted with conventionally identified P. endodontalis which we have in conservative dentistry laboratory. 3. The identification of P. endodontalis using PCR technique with samples collected from infected root canals or periapical lesions was more sensitive than that of culture methods. 4. Seven samples revealed including P. endodontalis by PCR technique. Five of them were related with pains, two of them with sinus tract, three of them with foul odor, and three of them with purulent drainage. P. endodontalis was shown to have great relation with pains.

  • PDF

학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교 (COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES)

  • 강문성;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 연구의 목적은 학생들이 사용한 세 가지 Ni-Ti파일의 성형효율을 비교하고, 각 파일의 사용 경험 유무에 따른 차이를 비교하여 치과대학생을 위한 교육에 적합한 종류를 선택하는데 도움을 얻고자하는 것이다. Ni-Ti파일 사용 경험이 없는 학생 50명과 Ni-Ti파일을 사용한 근관치료 경력이 2년 이상인 경험자 10명이 세 종류의 Ni-Ti file - $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$ -을 사용하여 180개의 근관 모형을 성형하였다. 근관성형 시간 및 기구 변형, 근관 이형성을 조사하고 성형 전후 상을 중첩하여 근관 삭제폭, 근관변위량과 중심변위율을 1, 3. 5 mm에서 분석하였다. 1. 근관 성형시간은 HS군이 가장 빨랐으며, 총 삭제 량은 모든 지점에서 K3군이 다른 군보다 컸다 (P<0.05) . 2. 세 군 모두 1, 3 mm에서 외측 변이를 보였고, 1 mm지점에서 PF군이 가장 안정적이었다 (P<0.05). 3. 중심변위율은 1, 3 mm에서 HS, PF군이 K3군보다 작았다. 5 mm지점에서는 PF군이 가장 작았고, PF군 3 mm에서 학생은 경험자보다 유의하게 작았다 (P<0.05).

Microseal®을 이용한 근관충전법의 근관폐쇄능력 평가 (EVALUATION OF THE SEALING ABILITY OF Microseal® OBTURATION TECHNIQUE)

  • 오태석;유현미;황혜경
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.682-689
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of the Microseal$^{(R)}$, which was new obturation system made by Tycom company, U.S.A. Forty-five extracted single-rooted human teeth were resected at cemento-enamel junction and divided three groups. All canals were prepared using Profile system, and then each group was obturated by lateral condensation technique (group 1), vertical condensation technique (group 2) and Microseal$^{(R)}$ condensation technique (group 3) with root canal sealer. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$ and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were resected horizontally at 1 mm (level I), 2 mm (level II), 3 mm (level III) from the anatomical root apex using low speed microtome and examined with Image analyzer (IBASR, Zeiss co., Germany.) at ${\times}25$ magnification. The gab between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was expressed percentage by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (one-way ANOVA). The results were as follows; 1. The mean ratio of leakage (%) was 6.46% at group 1, 3.06% at group 2, 11.27% at group 3. 2. When evaluating the ratio of leakage at the three levels, there was level I> level II> level III in all groups. Especially, the difference between level I and level III was statistically significant (p<0.05). 3. When evaluating the ratio of leakage at the three groups, there was group 3> group 1> group 2 at all levels. Especially the difference between group 2 and group 3 was statistically significant (p<0.05).

  • PDF

Experimental investigation of the effect of baffles on the efficiency improvement of irrigation sedimentation tank structures

  • Nouri, Alireza Zamani;Heydari, Mohammad Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제63권4호
    • /
    • pp.567-574
    • /
    • 2017
  • Sedimentation tanks are essential structures to filter the suspended sediments in the inlet flow which are constructed at the inlet of the basins forked from rivers and irrigation canals. The larger the constructed tank, the better the sedimentation process is conducted. However, the construction and dredging costs increase. In this regard, improving the performance and sedimentation efficiency seem necessary by alternative methods. One of these effective methods is using baffle plates. Most of the studies carried out in this field are on the use of these baffles in the primary and secondary sedimentation tanks. Hence, this study is carrier out with the objective of increasing the retention efficiency in the irrigation sedimentation tanks using baffles. To reach this goal, the experiments were carried out in a flume with length 8 meters, width 0.3 meters, and height 0.5 meters, considering a sedimentation tanks with a length of 3 meters, in three different inlet concentration, three flow rates and three Froude numbers. The baffles were mounted at the bottom of the tank and the effects of the angle, height and position in the tanks were investigated. The results showed that on average, employing the baffles increased the sedimentation efficiency 5 to 6% and the highest value was obtained for angle 60 with respect to the flow direction. According to the results of this study, the most favorable height and position of these baffles were obtained to be in 40% of the depth of the flow and 50% of the length of the sedimentation tank, respectively. Also, by increasing the number of baffles, the sedimentation efficiency decreased. Regarding the sedimentation regions in this case, more than 80% of the settled sediments were observed in the middle of the tank measured from the inlet.

Morphologic Diversities of Sacral Canal in Children;Three-Dimensional Computed Tomographic Study

  • Kim, Dae Wook;Lee, Seung Jun;Choi, Eun Joo;Lee, Pyung Bok;Jo, Young Hyun;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • 제27권3호
    • /
    • pp.253-259
    • /
    • 2014
  • Background: Caudal block is a common technique in children for reducing postoperative pain, and there have been several reports on the variations of the sacral canal in children. However, previous studies have mainly focused on the needle trajectory for caudal block, and there is limited information on the structural variations of the sacrum in children. The purpose of this study was to analyze the anatomic variations of sacral canals in children. Methods: Three-dimensional computed tomographic images were analyzed. The data from the images included (1) fusion of the sacral vertebral laminae and the sacral intervertebral space (2) existence of the sacral cornua and (3) the types of sacral hiatus. The types of sacral hiatus were classified into 3 groups: group I (fusion of S3 or S4 vertebral laminae), group II (unfused vertebral arch with the distance of the S3 and S4 vertebral laminae < 50% of the distance between the cornua), and group III (unfused vertebral arch with the distance of the S3 or S4 vertebral laminae ${\geq}50%$ of the distance between the cornua). Results: A total of 143 children were included in this study. All of the sacral vertebral arches were not fused in 22 children (15.4%). Cornua were not identified bilaterally in 5 (3.5%) and unilaterally in 6 (4.2%) children. In the sacral hiatus, group II and group III were identified in 22 (15.4%) and 31 (21.7%) children, respectively. Conclusions: The sacral canal has various anatomical variations in children. Careful attention must be paid to identify the correct anatomic landmark.

Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

  • Mohtavipour, Seiedeh Tahereh;Dalili, Zahra;Azar, Nasim Gheshlaghi
    • Imaging Science in Dentistry
    • /
    • 제41권1호
    • /
    • pp.7-10
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. Materials and Methods : Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-$15^{\circ}$, 15-$30^{\circ}$, > $30^{\circ}$). After the placement of a 15 K-file, radiographs were taken with a conventional film (Fspeed) and a digital sensor. Canal lengths were measured in these images by two observers. Statistical analysis was performed with repeated measures of ANOVA and paired sample t-test with 95% confidence. Results : There was a high inter-observer agreement on the measurements of working length in conventional and digital radiographs. There was no significant difference between the mean values of measurements in conventional and digital radiography. Moreover, there was no significant difference between conventional and digital radiography with the actual values in the basis of canal curves. Conclusion : The accuracy of conventional and digital radiography in the determination of the working length was in an acceptable range.

16S rDNA 클론 Libraries를 이용한 치근단 농양 병소의 세균 동정 (Identification of Bacteria from Periapical Abscess Using 16S rDNA Clone Libraries.)

  • 유소영;김미광;김화숙;황호길;김평식;임성훈;오상호;민정범;국중기
    • 한국미생물·생명공학회지
    • /
    • 제32권2호
    • /
    • pp.195-198
    • /
    • 2004
  • Molec-ular analysis was performed on the microflora found In the necrotic pulpal tissue collected from 5 infected root canals that were diagnosed as a periapical abscess. 16S rRNA coding gene (rDNA) library construction and sequencing were performed in order to identify the microflora, The 16S rDNA sequences from 278 clones were identified by a comparison with the database sequence in GenBank. Three phylum and 31 species, which were related to the oral microflora, were identified from the 3 samples (No. 87, 105, and 115). Dialister invisus (5.6%), Peptostreptococcus micron (18.3%), and Veillonella sp. (3.3%) were the organism present in all tee samples. Lac-tobacillusfementum (2.8%),Eubacterumsp./E. infirmum (6.7%), Shuttleworthiasatelles (3.9%), Psudorarnihacfer alactoiyticus (13.3%), Bulleidia moorei (2.8%), and Prevotella denticola (1.1%) were found in two samples. Two phylum and low species of environmental microflora were identified from 2 samples (No.95 and 101). The reason for this might be contamination of the samples with dental water. These results showed that molecular analysis could reveal more diverse microflora that are associated with endodontic infections than that revealed by conventional cultural methods. In addition, these results may of for the basic data to epidemiological studies related with endodontic infection.