• Title/Summary/Keyword: Three Line Sensor

Search Result 131, Processing Time 0.029 seconds

Development of wireless/battery-free Love wave biosensor (무선/무전원 러브파 바이오센서 개발)

  • Nam, Min-Woo;Oh, Hae-Kwan;Lee, Kee-Keun;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1545_1546
    • /
    • 2009
  • This paper reports a novel wireless love-wave biosensor on $41^{\circ}$ YX $LiNbO_3$ piezoelectric substrate and $SiO_2$ guiding layer for Immunoglobulin G (IgG) detection by protein binding. Different from the traditional biosensors based on surface acoustic wave (SAW) oscillator structured by delay line/resonators, a 440MHz reflective delay line consists of SPUDTs and three reflectors placed on $41^{\circ}$ YX $LiNbO_3$ in a row was fabricated as the sensor element. Good linearity, reproducibility, and high sensitivity were observed in the IgG concentration range 1~65nM. Unique advantages as high sensitivity, passive and simple measurement system are present over currently available other biosensors.

  • PDF

Adaptive beamforming of triplet arrays for active sonar systems (능동소나 시스템을 위한 삼중 배열의 적응 빔형성)

  • Ahn, Jae-Kyun;Ryu, Yongwoo;Chun, Seung-Yong;Kim, Seongil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.66-72
    • /
    • 2018
  • In this paper, we propose an adaptive beamforming algorithm of triplet arrays for active sonar systems. The proposed algorithm consists of three steps: matched filters, cardioid beamforming, and line array beamforming. First, we apply a matched filter of a transmitted pulse to received individual sensor signals and obtain filterd signals. Then, we perform the fast Fourier transform to the matched filter results, and make a cardioid beam for each triplet data, respectively. Finally, we apply an adaptive beamforming by assuming that the cardioid beams are input signals of a line array. Experimental results demonstrate that the proposed algorithm provides better performances than conventional algorithms.

In-situ Calibration of Membrane Type Dissolved Oxygen Sensor for CTD (CTD용 박막형 용존산소 센서의 현장 교정)

  • DONG-JIN KANG;YESEUL KIM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.41-50
    • /
    • 2023
  • Dissolved oxygen sensors have characteristics in which data drift occurs over time. Therefore, in-situ calibration of the dissolved oxygen sensor is essential to accurately measure the concentration of dissolved oxygen in seawater. In order to provide a method for in-situ calibration, appropriate number of samples for calibration, and laboratory calibration interval of the dissolved oxygen sensor, the dissolved oxygen sensor values were compared with the measured values by titration on a total of 133 samples from three different cruises in the Indian Ocean, Pacific Ocean, and East Sea over a period of about one year. As a result, it is preferable to calibrate the sensor value using the correlation of a straight line obtained by directly comparing the final concentration value given by the sensor and the measured value. For the accurate calibration, at least 30 samples must be used to enable in-situ calibration within an accuracy range of about 1%. In addition, it is recommended that a laboratory calibration should perform within 1 year for the membrane type dissolved oxygen sensor for CTD to achieve a performance of 70% or more.

Development of the pulse analyzing system using FBG (FBG를 이용한 맥진 시스템 개발)

  • Jeon, Young-Ju;Lee, Jeon;Ryu, Hyun-Hee;Lee, Jae-Hoon;Lee, Si-Woo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF

Telemetering System of Extremely Low Frequency Magnetic Field Intensity (극저주파 자계 세기를 원격 측정하는 장치)

  • Yoo, Ho-Sang;Wang, Jong-Uk;Seo, Geun-Mee;Gimm, Yoon-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.553-562
    • /
    • 2007
  • In this paper, we designed and implemented the system for telemetering ELF(Extremely Low Frequency) magnetic field intensity. The magnetic field measurement system used a 3-axis magnetic field sensor to measure the magnetic field with isotropy and the equalizer to compensate the frequency characteristic in band. By multiplexing three output signals of the magnetic field sensor in time domain, we got the uniform gain and frequency characteristic among three axes. This system was designed that the magnetic field measurement level range was $0.01{\sim}10.0\;uT$ and the measurement frequency band was $40{\sim}180\;Hz$. The control system would access to the magnetic field measurement system with RF and the maximum access distance was 1.0 km. We confirmed that the measurement level error of the fabricated system was within 5 %. The fabricated system was installed to a golf practice range where a high voltage power transmission line was crossed.

Linear Predictor Using Charge-Coupled Devices (CCD를 이용한 선형예측기)

  • 최태영;신철재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.1
    • /
    • pp.9-18
    • /
    • 1987
  • An electro-optic system using linear photosensitive Charge Coupled Devices(CCDs) having dummy pixels has been proposed for realzation of linear prodictor in the differential pulse code modulation(DPCM). The system consists of three components as conventional system:input light source, spatial filter(mask) and CCD line scanning sensor. For the delay time due to the dummy pixels in CCD, modifying conventional mask, a new dispersive mask is proposed, of which every prediction coefficient is dispersed on the more than one element, the characteristics of the system using the proposed dispersive mask are analyzed theoretically and verified with experiment.

  • PDF

Design of Broad Band RF Components for Partial Discharge Monitoring System (부분방전 모니터링 시스템을 위한 광대역 RF 소자설계 연구)

  • Lee, Je-Kwang;Ko, Jae-Hyeong;Kim, Koon-Tae;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2286-2292
    • /
    • 2011
  • In this paper we present the design of Low Noise Amplifier(LNA), mixer and filter for RF front-end part of partial discharge monitoring system. The monitoring system of partial discharge in high voltage power machinery is used to prevent many kinds of industrial accidents, and is usually composed of three parts - sensor, RF front-end and digital microcontroller unit. In our study, LNA, mixer and filter are key components of the RF front-end. The LNA consists of common gate and common source-cascaded structure and uses the resistive feedback for broad band matching. A coupled line structure is utilized to implement the filter, of which size is reduced by the meander structure. The mixer is designed using dual gate structure for high isolation between RF and local oscillator signal.

Implementation of a 3 Phase Voltage-Sourced PWM Converter Using the Sensorless Input Current Controller (비검출 전류 제어기를 사용한 3상 전압형 PWM CONVERTER 구현)

  • Kang, Dong-Ku;Lee, Woo-Cheol;Kweon, Seong-Kon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2210-2212
    • /
    • 1997
  • A sensorless input current controller for three phase PWM converter is proposed. A merit of this controller is that sinusoidal input line current, unity power factor, and ripple-free DC voltage can be achieved with low-cost. The paper describes the proposed control strategy and its implementation. Simulation result for the proposed controller is compared with that of the sensor based version.

  • PDF

A Robust Real-Time Mobile Robot Self-Localization with ICP Algorithm

  • Sa, In-Kyu;Baek, Seung-Min;Kuc, Tae-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2301-2306
    • /
    • 2005
  • Even if there are lots of researches on localization using 2D range finder in static environment, very few researches have been reported for robust real-time localization of mobile robot in uncertain and dynamic environment. In this paper, we present a new localization method based on ICP(Iterative Closest Point) algorithm for navigation of mobile robot under dynamic or uncertain environment. The ICP method is widely used for geometric alignment of three-dimensional models when an initial estimate of the relative pose is known. We use the method to align global map with 2D scanned data from range finder. The proposed algorithm accelerates the processing time by uniformly sampling the line fitted data from world map of mobile robot. A data filtering method is also used for threshold of occluded data from the range finder sensor. The effectiveness of the proposed method has been demonstrated through computer simulation and experiment in an office environment.

  • PDF

An efficient alignment method of the Stereoscopic camera for three dimensional image acquisition (입체 영상 획득용 Stereoscopic Camera의 효율적 정렬 방법)

  • 김재한
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.575-578
    • /
    • 2001
  • 원격 조작이나 해저 수중 탐사에서 실제와 같이 거리감을 인식하며 제어하기 위하여, 3차원 입체 영상 카메라 장치를 사용하고 있다. 기본적인 구성 형태인 Stereoscopic Camera 시스템은 기구적으로 주시각 제어와 초점 제어가 이루어 지고 있으며, 획득영상에 대하여 영상 distortion 보정, 압축 처리 등의 영상 신호처리가 행하여진다. 양안 카메라의 수평 위치를 일치시켜 수평적으로 동일 위치의 pixel들이 정확한 epipolar line을 형성할 경우에, 주시각 제어가 용이하고 보정 및 영상처리 등의 연산량이 대폭 감소된다. 이와 같은 calibration 과정을, 기존의 시스템에서는, 주로 영상 획득 포기에 패턴을 사용하여 실시하거나, 물리적 수평 장치와 sensor 등의 보조 장치를 이용하여 calibration을 행한다. 그러나, 기계적으로 정밀하게 정렬을 한다고 하여도 두 카메라의 광축 및 CCD조립상 상이점과 특성의 불일치로 인하여 실제 획득된 영상에서는 변이와 회전이 포함된 영상을 얻게된다. 본 논문에서는 Stereoscopic Camera의 위와같은 정렬 오류의 문제점을 분석한 후, 제안 방식으로서 두 카메라의 획득되는 영상을 직접 영상 처리하여 수직 방향 및 회전 오류를 최소화 시켜 정렬하는 새로운 방법을 제시하며, 실험적으로 제안 방식의 효율성을 보인다.

  • PDF