• Title/Summary/Keyword: Three Cavities

Search Result 238, Processing Time 0.026 seconds

Clinical Courses of Cavitary Lesions in Pulmonary Tuberculosis (처음 진단시 발견된 공동성병변의 경과)

  • Park, Seung-Kyu;Choi, In-Hwan;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.323-330
    • /
    • 1996
  • Objective : Cavitary lesion in pulmonary tuberculosis sometimes makes problems in the course of treatment. Especially, retreatment cases tend to respond poorly to current antituberculosis agents. So, authors tried to render a guideline for clinical approach toward cavitary lesions in pulmonary tuberculosis. Methods : Retrospective analysis of 33 pulmonary tuberculosis patients with cavitary lesions was made. All the patients had got treatment at National Masan Tuberculosis Hospital from Jan. 1995 to Aug. 1995. Results: The ratio between male and female was 10:1. Age distribution was 69.7% in 3rd and 4th decades. The locations of cavitary lesion were 60.6% in right upper lung field and 36.4% in left upper lung field. In the extent of disease, there were 12 cases(36.4%) in moderate advanced and 21 cases in far advanced. Cavitary lesions were closed in 5 eases and remained in 28 eases. In the cases of closed cavity, it was happened within $10.6{\pm}4.72$ months after they took treatment, the size of cavity was $35.5{\pm}17.1$ in long diameter, $27.0{\pm}12.2$ in short diameter and $4.6{\pm}2.1\;mm$ in wall thickness. In the cases of remained cavity, the size of cavity was $31.9{\pm}12.3$ in long diameter, $21.0{\pm}9.8$ in short diameter and $5.04{\pm}2.0\;mm$ in wall thickness. In terms of negative conversion, it took $3.8{\pm}2.17$ months in the case of closed cavity but it was happened within 5 months for only 4 patients in the case of remained cavity. In the point of past medication history, there was none in closed cavities but there were none in 1 case, once in 3 cases, two times in 9 cases and more than three times in 13 cases among remained cavitary lesions. Conclusion : In the retreatment cases of pulmonary tuberculosis with cavitary lesions, they tend to respond poorly to current antituberculosis agents. So, if the lesions are localized, operative intervention may be a proper method as adjunctive treatment.

  • PDF

IN VITRO COMPARISON OF VARIOUS DIAGNOSTIC METHODS OF OCCLUSAL CAR10US LESIONS (교합면 우식병소의 다양한 진단법에 관한 비교연구)

  • Kim, Jae-Gon;Kim, Young-Jin;Kim, Young-Sin;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.613-619
    • /
    • 2001
  • The aims of this study were to compare the accuracy, sensitivity and specificity of cnventional visual examination, radiography and a new laser fluorescence method, KaVo Diagnodent, for the detection of occlusal caries lesions. One hundred sound human premolars and molars which had no restorations or interproximal cavities were tested by three methods. Tooth lesions depth was assessed at histologic examination using Caries detector dye The following results were obtained. 1. Diagnodent show 7.8 in sound tooth, 25.4 in initial caries, 30.5 in enamel caries, and 53.8 in dentin caries with average score 2. Spearman and Pearson relation coefficient was high between tooth-specimen test with dye and Diagnodent(0.736, 0.619), visual examination(0.664, 0.666), and was low between tooth-specimen test with dye and radiographic examination(P<0.01, total) 3. Accuracy of occlusal caries was highest on Diagnodent(65%) and lowest on radiographic examination(35%) 4. In initial caries, the sensitivity and specificity of Diagnodent method was the highest. In enamel caries, the sensitivity of visual examination was the highest and specificity of Diagnodent method was the highest. In dentinal caries, the sensitivity and specificity of Diagnodent method was the highest and sensitivity of visual examination was the lowest.

  • PDF

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN CLASS V RESIN RESTORATIONS WITH OR WITHOUT MECHANICAL RETENTION (접착제와 와동형성의 차이에 따른 5급 복합레진 수복의 전향적 임상연구)

  • Lee Kyung-Wook;Choung Sae-Joon;Han Young-Chul;Son Ho-Hyun;Um Chung-Moon;Oh Myoung-Hwan;Cho Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.300-311
    • /
    • 2006
  • The purpose of this study is to evaluate prospectively the effect of different bonding systems and retention grooves on the clinical performance of resin restorations in non-carious cervical lesions (NCCLs). Thirty-nine healthy adults who had at least 2 NCCLs in their premolar areas were included in this study. One hundred and fifty teeth were equally assigned to six groups: (A) Scotchbond Multi-Purpose (SBMP, 3M ESPE, St. Paul, MN, USA, 4th generation bonding system) without retention grooves; (B) SBMP with retention grooves; (C) BC Plus (Vericom Co., Anyang, Gyeonggido, Korea, 5th generation bonding system) without retention grooves; (D) BC Plus with retention grooves; (E) Adper Prompt (3M ESPE, Seefeld, Germany, 6th generation bonding system) without retention grooves; (F) Adper Prompt with retention grooves. All cavities were filled with a hybrid composite resin. Denfil (Vericom Co., Anyang, Gyeonggido, Korea) by one operator. Restorations were evaluated at baseline and at 6-month recall, according to the modified USPHS (United States Public Health Service) criteria. Additionally, clinical photographs were taken and epoxy resin replicas were made for SEM evaluation. At 6-month recall, there were some differences in the number of alpha ratings among the experimental groups. But, despite the differences in the number of alpha ratings, there was no significant difference among the 3 adhesive systems (p < 0.05). There was also no significant difference between the groups with or without mechanical retention (p < 0.05). Follow-ups for longer periods than 6 months are needed to verify the clinical performance of different bonding systems and retention grooves.

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.

Synthesis and Structural Study of Extraframework ZrI6Tl119+ Cationic Cluster in Zeolite A (제올라이트 A 동공 내 비골격 ZrI6Tl119+ 양이온 클러스터의 합성과 구조 연구)

  • Hyeon Seung, Lim;Jong Sam, Park;Cheol Woong, Kim;Woo Taik, Lim
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.447-455
    • /
    • 2022
  • Fully dehydrated Tl12-LTA (|Tl12|[Si12Al12O48]-LTA,Tl12-A) was treated with 6.0×103 Pa of ZrI4 (g) at 623 K for 72 hr under anhydrous conditions. The crystal structure of product, |Zr0.25I1.5Tl12|[Si12Al12O48]-LTA, was determined by single-crystal crystallography using synchrotron X-radiation in the cubic space group Pm3m (a = 12.337(2) Å). It was refined using all data to the final error index (for the 712 unique reflections for which Fo> 4σ(Fo) R1/wR2= 0.055/0.189. In this structure, octahedral ZrI62- ions center about 25% of the large cavities (Zr-I = 2.91(4) Å). Each coordinates to eight Tl+ ions and they are further bridged by Tl+ ions in the planes of 8-rings to form a cubic three-dimensional ZrI6Tl119+ cationic cluster. About 1.5 Tl+ ions per unit cell moved to deeper side of sodalite cavity after reaction with ZrI4(g). The remaining Tl+ ions occupy well-established cation positions near 6- and 8-rings.

A Study of the Bracelets Excavated from Fifth-and Sixth-century Silla Kingdom Tombs: Physical Characteristics and Wearing Practices (신라 5~6세기 무덤 출토 팔찌에 대한 연구 -물리적·형태적 특성 및 착장 양상을 중심으로)

  • Yoon Sangdeok
    • Bangmulgwan gwa yeongu (The National Museum of Korea Journal)
    • /
    • v.1
    • /
    • pp.174-197
    • /
    • 2024
  • Personal ornaments made from precious metals that have been excavated from tombs dating to the Maripgan period (4th-6th century) of the Silla Kingdom are a major subject of analysis in the study of gender and hierarchy among the tomb occupants. Nonetheless, bracelets had been neglected until Ha Daeryong's recent research on determining gender through bracelets attracted attention. Accordingly, an examination and organization of the fundamental elements of Silla bracelets was needed. In response, this paper examines their physical characteristics, appearance, changes over time, and related wearing practices. The data for this study is derived from 176 bracelets, mostly made from silver or gold. Copper and glass bracelets are also included. Many of them were cast in a single-use earthen mold. Even the notched and protruding designs were created by casting rather than carving. Glass bracelets and bracelets with dragon designs were made using molds with round cavities. Excluding those produced using metal sheets, the rest of the bracelets are thought to have been cast in a mold with a long-string-shaped cavity and then bent round. After being bent, the two ends were either soldered together (closed type) or left open (open type). As demonstrated in the study by Lee Hansang, Silla bracelets evolved from plain rounded rod-shaped bracelets, such as the one excavated from the Northern Mound of Hwangnamdaechong Tomb, to versions with notched designs, and eventually to those with protruding designs, which gained popularity by the sixth century. The precedents of plain rounded rod-shaped bracelets are presumed to have been thin rod-shaped bracelets from the Proto-Three Kingdoms period. Bracelets need to be fit to the wrists so that they do not slip off easily when worn. The open type design was the preferable way to achieve this. Moreover, given the ductility of gold, silver, and copper, it seems that it would have been possible to stretch or deform them. In the end, I concluded that even if a bracelet is too small to pass man's hand, the open type could have been worn. Furthermore, if a closed-type bracelet were pressed into an oval shape, it would not be impossible for a man to put it on. When bracelets are divided according to their degree of deformability into type A (the open type) through type D, which is almost impossible to deform, type A is commonly found with wearers of thin hollow earrings, and types C and D (which are difficult to deform) are not found with wearers of thin hollow earrings, but only with wearers of thick hollow earrings. Therefore, it can be seen that men were allowed to wear bracelets, and the existing studies that differentiate between men and women based on the wearing of thin hollow earrings, thick hollow earrings, and swords remain valid.

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF