• Title/Summary/Keyword: Three Cavities

Search Result 240, Processing Time 0.028 seconds

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

EFFECT OF CATALASE APPLICATION ON MICROLEAGKAGE OF COMPOSITE RESIN RESTORATION IN BLEASCHED CAVITY (표백처리된 와동의 catalase 처리가 복합레진 수복물의 미세누출에 미치는 영향)

  • Kim, Jong-Uk;Cho, Young-Gon;Moon, Joo-Hoon;Suck, Ohn-Yeong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.392-398
    • /
    • 1999
  • The purpose of this study was to assess the effect of catalase used following bleaching for the elimination of hydrogen peroxide residues from human teeth on the microleakage at the tooth-resin composite interface. In this study, class V cavities were prepared on the buccal or lingual surfaces of seventy extracted human molar teeth, and crown of sixty teeth were immersed in 30% hydrogen peroxide at $37^{\circ}C$ for 5 days except for negative control group. Then the teeth were rinsed with water and distributed randomly into seven groups of 10 each and were conditioned as following Negative control group: No bleaching Positive control group : bleaching and no application of catalase (C-40) Experimental group 1 : one cycle of catalase application for 3 min. and water rinse for 2 min. after bleaching Experimental group 2 : two cycles of catalase application for 3 min. and water rinse for 2 min. after bleaching Experimental group 3 : three cycles of catalase application for 3 min. and water rinse for 2 min. after bleaching Experimental group 4 : four cycles of catalase application for 3 min. and water rinse for 2 min. after bleaching Experimental group 5 : five cycles of catalase application for 3 min. and water rinse for 2 min. after bleaching The cavities of each groups were restored with composite resin. The teeth were thermocycled, stained with 2% methylene blue, and sectioned buccolingually. Degree of dye penetration at tooth-restoration interfaces were examined by stereomicroscope(${\times}30$) at occlusal and gingival margin The results were as follows : 1. On the occlusal margin, there was no significant difference in the microleakage between the negative coltrol group and experimental groups (p>0.05). But on the gingival margin, experimental groups showed higher microleakage than the negative coltrol group (p<0.05). 2. On the occlusal margin, positive coltrol group showed higher microleakage than experimental groups (p<0.05) and among the experimental groups, group 1 showed higher microleakage than group 3, 4, 5 (p<0.05). 3. On the gingival margin, there was no significant difference between the positive coltrol group and experimental groups, and between experimental groups (p>0.05). The result indicated that catalase used in bleached cavity for the elimination of hydrogen peroxide residues from human teeth maybe reduced microleakage at the tooth-resin composite interface.

  • PDF

IN VIVO CHANGES OF THE ACIDITY OF VARIOUS DENTAL LINERS (In vivo에서 수종이장재의 산도변화에 관한 연구)

  • Lee, Mi-Jeong;Ahn, Yun-Sil;Lee, Yong-Woo;Son, Ho-Hyun;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.433-442
    • /
    • 1998
  • The purpose of this study was to observe the changes of acidity of resin cement(Time Line), glass ionomer cement(GC Fugi Lining LC), zinc phosphate cement(Fleck's zinc cement). zinc oxide eugenol cement(Sultan,Chemists.) in vivo and in vitro. Class I cavities with 3mm depth were prepared on the occlusal surfaces of 20 recently extracted human Mn. molar teeth and 20 human Mn. 3rd molar teeth in oral cavity. The prepared cavities were divided into 4 groups of each 5 teeth using the above 4 cavity liners. Each cement was mixed in accordance with manufacturer's direction at the room temperature of $23^{\circ}{\pm}5^{\circ}C$ and filled into the cavity in a width of 1 mm. The microelectrode of pH meter was inserted into the prepared cavity which was filled with mixed cement, and the acidity of cement was measured for 3 days from the beginning of cement mix in vitro and in vivo. The measured acidity was then statistically analyzed by ANOVA. The results were as follows. 1. In vitro, the pH of zinc oxide eugenol cement was statistically lower than that of the three other groups at 2min, 4min, 6min, 8min, 10min, 12min, 18min, 20min. (p<0.05). 2. The pH of zinc oxide eugenol cement in vivo was statistically higher than that in vitro at 16min,16min, 20min(p<0.05). 3. The pH of zinc phosphate cement in vivo was statistically higher than that in vitro at 4min, 20min(p<0.05). 4. In vitro and in vivo, there was no significant difference in the pH between the resin cement and the glass ionomer cement(p>0.05). 5. The initial acidity was not high, but almost neutral in all kinds of the cements.

  • PDF

Oral Health Belief and Oral Health Behaviors in nursing college students (일대학 간호학 전공 학생의 구강건강신념과 구강건강행태)

  • Lee, JinHee;Lee, JungHyeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1413-1420
    • /
    • 2018
  • This study was conducted to provide the information for the promotion of oral health in nursing students. The subjects were 207 in female students for self-administered questionnaires. The percentage of subject to visit dental clinic was 64.3%, to Regular checkup was 25.9%, cure of caries was 23.5% for last one year. The percentage of reasons not treated 'less importance' were 12.6%, 'fear of the dental clinic' was 10.6%. The average number of brushing teeth were 3.1. 56.0% students brush their teeth for two ~ three minutes. But intention of visit to the dentist were 'only when treated' was 51.7%, 'only when there is pain' was 10.1%. The intention of oral education was 54.6%, the content of the desired education 'whitening' were 34.5%, 'prevention of bad breath' was 19.2%. Dental health information acquisition path 'internet' were 42.0%, 'family or friends' was 25.6%. Susceptibility was 2.47 points, severity was 2.00 points, benefit was 4.03 points in oral health belief. Compared to students who needed dental treatment but did not receive treatment, oral health beliefs were higher among those who were treated(p<.001), students with cavities showed a higher level of oral health belief than those without cavities(p<.001). There was significant corelation between 'number of caries' and susceptibility(r=.330, p=.002), severity(r=.25, p=.019). The result should be reflected in the development of effective program for nursing students' oral health care.

Analysis of the crack propagation rules and regional damage characteristics of rock specimens

  • Li, Yangyang;Xu, Yadong;Zhang, Shichuan;Fan, Jing;Du, Guobin;Su, Lu;Fu, Guangsheng
    • Geomechanics and Engineering
    • /
    • v.24 no.3
    • /
    • pp.215-226
    • /
    • 2021
  • To study the evolution mechanism of cracks in rocks with multiple defects, rock-like samples with multiple defects, such as strip-shaped through-going cracks and cavity groups, are used, and the crack propagation law and changes in AE (acoustic emission) and strain of cavity groups under different inclination angles are studied. According to the test results, an increase in the cavity group inclination angle can facilitate the initial damage degree of the rock and weaken the crack initiation stress; the initial crack initiation direction is approximately 90°, and the extension angle is approximately 75~90° from the strip-shaped through-going cracks; thus, the relationship between crack development and cavity group initiation strengthens. The specific performance is as follows: when the initiation angle is 30°, the cracks between the cavities in the cavity group develop relatively independently along the parallel direction of the external load; when the angle is 75°, the cracks between the cavities in the cavity group can interpenetrate, and slip can occur along the inclination of the cavity group under the action of the shear mechanism rupture. With the increase in the inclination angle of the cavity group, the AE energy fluctuation frequency at the peak stress increases, and the stress drop is obvious. The larger the cavity group inclination angle is, the more obvious the energy accumulation and the more severe the rock damage; when the cavity group angle is 30° or 75°, the peak strain of the local area below the strip-shaped through-going fracture plane is approximately three times that when the cavity group angle is 45° and 60°, indicating that cracks are easily generated in the local area monitored by the strain gauge at this angle, and the further development of the cracks weakens the strength of the rock, thereby increasing the probability of major engineering quality damage. The research results will have important reference value for hazard prevention in underground engineering projects through rock with natural and artificial defects, including tunnels and air-raid shelters.

NEW QUANTITATIVE MEASURING TECHNIQUE FOR MICROLEAKAGE OF THE RESTORED TOOTH THROUGH 3D RECONSTRUCTION (3차원 재구성법을 이용한 수복물의 정량적 미세누출도 측정)

  • Ha, Sang-Yoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.413-422
    • /
    • 2004
  • Established microleakage tests have their own disadvantages. In this study, 3D reconstruction method was tried to overcome these disadvantages. Four types of microleakage tests were used and relationships among them were estimated: penetrated dye volume: marginal adaptability: degree of dye penetration and relative penetrated length to cavity wall. Twenty-four Class V cavities were bulk filled with composite (Esthet X) following surface treatments: N group (no treatment): E group (etching only): T group (etching + Prime & Bond NT). 50% silver nitrate was used as a dye solution after thermocycling ($5^{\circ}C{\;}&{\;}55^{\circ}C$, 1.000 times). Teeth were serially ground with a thickness of 0.2 mm. Volume of dye penetration was estimated from a three-dimensionally reconstructed image with a software (3D-DOCTOR). Percentage of margin without gap was estimated from SEM and degree of dye penetration and the relative length of dye penetration to overall cavity wall were also estimated. ANOVA and Scheffe test for dye volume, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman's rho test for checking of relationships among methods were used. The results were as follows: 1. Dye penetration could be seen from several directions, furthermore, its volumetric estimation was possible. 2. Reverse relationship was found between dye volume and marginal quality (r = -0.881/ p = 0.004). 3. Very low relationship was seen between dye volume and two-dimensional tests (degree of dye penetration and relative length). However, 2D evaluation methods showed high relationship (p = 0.002-0.054) each other. 4. Three times vertical section could be recommended as a 2D test.

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

Three-dimensional morphological evaluation of the hard palate in Korean adults with mild-to-moderate obstructive sleep apnea

  • Yu, Chen;Ahn, Hyo-Won;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.48 no.3
    • /
    • pp.133-142
    • /
    • 2018
  • Objective: The purpose of this study was to evaluate differences in three-dimensional (3D) morphology of the hard palate between Korean adults with and without mild-to-moderate obstructive sleep apnea (OSA) using cone-beam computed tomographic (CBCT) data. Methods: The protocol for the two-dimensional (2D) and 3D mathematical modeling was established by analyzing CBCT images of 30 adults with OSA and 30 matched controls without OSA, using MIMICS software. The linear and angular measurements were also determined using this software. The measurements were repeated for 30 palates, by the same operator, to assess reliability. Results: The palates of OSA patients were higher in the posterior part and narrower in the anterior-superior part than those of the control group (p < 0.05). The nasal cavities of patients with OSA were narrower (p < 0.05) than those of controls. The increasing angle of the first molar palatal root is a compensation of the upper dental arch to improve occlusion. However, for most palatal measurements, there were no significant differences between the OSA and control groups (p > 0.05). The results of 2D and 3D mathematical models were consistent for linear and angular measurements, indicating that 2D and 3D mathematical modeling of the palate is a reliable methodology. Conclusions: OSA is a multifactorial disease; the palates of adults with mild-to-moderate OSA do not have specific morphological features distinct from those of healthy controls.

Microstructural and Wear Properties of WC-based and Cr3C2-based Cermet Coating Materials Manufactured with High Velocity Oxygen Fuel Process (고속 화염 용사 공정으로 제조된 WC계 및 Cr3C2계 Cermet 코팅 소재의 미세조직 및 마모 특성)

  • Kang, Yeon-Ji;Ham, Gi-Su;Kim, Hyung-Jun;Yoon, Sang-Hoon;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.25 no.5
    • /
    • pp.408-414
    • /
    • 2018
  • This study investigates the microstructure and wear properties of cermet (ceramic + metal) coating materials manufactured using high velocity oxygen fuel (HVOF) process. Three types of HVOF coating layers are formed by depositing WC-12Co, WC-20Cr-7Ni, and Cr3C2-20NiCr (wt.%) powders on S45C steel substrate. The porosities of the coating layers are $1{\pm}0.5%$ for all three specimens. Microstructural analysis confirms the formation of second carbide phases of $W_2C$, $Co_6W_6C$, and $Cr_7C_3$ owing to decarburizing of WC phases on WC-based coating layers. In the case of WC-12Co coating, which has a high ratio of $W_2C$ phase with high brittleness, the interface property between the carbide and the metal binder slightly decreases. In the $Cr_3C_2-20CrNi$ coating layer, decarburizing almost does not occur, but fine cavities exist between the splats. The wear loss occurs in the descending order of $Cr_3C_2-20NiCr$, WC-12Co, and WC-20Cr-7Ni, where WC-20Cr-7Ni achieves the highest wear resistance property. It can be inferred that the ratio of the carbide and the binding properties between carbide-binder and binder-binder in a cermet coating material manufactured with HVOF as the primary factors determine the wear properties of the cermet coating material.