• Title/Summary/Keyword: Thread implantation

Search Result 12, Processing Time 0.013 seconds

RADIOGRAGHIC STUDY OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANTS AFTER FUNCTIONAL LOADING (보철물 장착후 골 유착성 임플란트 변연골 소실에 관한 방사선학적 연구)

  • Park, Ki-Hyun;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.806-815
    • /
    • 1998
  • Regular radiographic examination has been considered as an essential diagnostic method for the osseointegrated dental implantation. This study investigated the marginal bone loss through the measurement on the periapical radiograph around 46 endosseous dental implants. Marginal bone loss have been observed for 5 years after delivery of prostheses. The results were as follows : 1. According to the experimental periods, average marginal bone loss in total implant was 1.821mm in the first year, 1.833mm in the second, 1.892mm at third, 1.910mm at forth and 1.957mm at fifth after delivery of prostheses(P<0.05). 2. The average bone loss was 1.832mm in the maxillae and 1.819mm in the mandible in three years but there was no significant difference between the upper and lower jaw(P>0.05). 3. The average bone loss was 1.824mm in males and 1.818mm in females in five years but there was no significant difference according to the sex(P>0.05). These results indicate that the most of the alveolar bone loss occur within the first year after delivery of dental prostheses resulting in the exposure of polished neck positions, and the bone level stabilizes at first thread portion of the implant fixtures.

  • PDF

A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS (표면처리가 다른 5종 임플랜트의 안정성에 관한 연구)

  • Kim Sun-Jong;Shin Sang-Wan;Jung Sung-Min;Ryu Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.