• Title/Summary/Keyword: Thoracic manipulation

Search Result 40, Processing Time 0.019 seconds

Cabrol Technique Application in Off-pump Coronary Artery Bypass Grafting Using Radial Artery (인공심폐기를 이용하지 않는 관상동맥우회술 시 요골동맥을 이용한 Cabrol 술식의 응용)

  • Na, Chan-Young;Oh, Sam-Se;Kim, Soo-Cheol;Kim, Jae-Hyun;Jo, Won-Min;Seo, Hong-Ju;Lee, Cheul;Chang, Yun-Hee;Kang, Chang-Hyun;Lim, Cheong;Baek, Man-Jong;Whang, Song-Wok;Choi, In-Seok;Kim, Woong-Han;Park, Yoon-Ock;Moon, Hyun-Soo;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.630-632
    • /
    • 2003
  • In off-pump coronary artery bypass grafting (CABG), multiple proximal anastomosis may increase the risk of cerebral embolism (air, debris) and aortic injury (dissection, pseudoaneurysm). Radial artery (RA) has no intraluminal valve such as saphenous vein. We applied Cabrol technique using aortic root replacement for proximal anastomosis in off-pump CABG. Cabrol technique using RA graft can reduce numbers of proximal anastomosis and reduce number of aortic manipulation in off-pump CABG. We report a Cabrol technique for proximal anastomosis in off-pump CABG with RA graft.

Minimally Invasive Surgery in Esophagus and Upper Mediastinum (상부 종격동 및 식도의 최소 침습적 수술)

  • Kang, Chang-Hyun
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Minimally invasive surgery (MIS) has several advantages over conventional open surgery. Less pain, less morbidity, early recovery and better cosmetic outcomes are well-known benefits of MIS. However, indications of MIS are highly dependent on the experience of surgeon and the disease status, In the benign diseases with less surgical complexity, MIS can be performed relatively and safely. However. in advanced malignant diseases which require more complex surgical manipulation, the of patients and the principles of oncologic surgery should be considered before the selection of surgical methods, MIS would be performed more and more with aid or technologic advancement. However, long-term result with equivalent oncologic outcomes to open surgery is necessary to be one of standard surgical treatments in thoracic surgery.

  • PDF

Clinical Outcomes of Minimally Invasive Surgical Stabilization of Rib Fractures Using Video-Assisted Thoracoscopic Surgery

  • Chae-Min Bae;Shin-Ah Son;Yong Jik Lee;Sang Cjeol Lee
    • Journal of Chest Surgery
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2023
  • Background: Multiple rib fractures are common in blunt chest trauma. Until recently, most surgical rib fixations for multiple rib fractures were performed via open thoracotomy. However, due to the invasive nature of tissue dissection and the resulting large wound, an alternative endoscopic approach has emerged that minimizes the postoperative complications caused by the manipulation of injured tissue and lung during an open thoracotomy. Methods: Our study concentrated on patients with multiple rib fractures who underwent surgical stabilization of rib fractures (SSRF) between June 2018 and May 2020. We found 27 patients who underwent SSRF using video-assisted thoracoscopic surgery. The study design was a retrospective review of the patients' charts and surgical records. Results: No intraoperative events or procedure-related deaths occurred. Implant-related irritation occurred in 4 patients, and 1 death resulted from concomitant trauma. The average hospital stay was 30.2±20.1 days, and ventilators were used for 12 of the 22 patients admitted to the intensive care unit. None of the patients experienced major pulmonary complications such as pneumonia or acute respiratory distress syndrome. Conclusion: Minimally invasive rib stabilization surgery with the assistance of a thoracoscope is expected to become more widely used in patients with multiple rib fractures. This method will also assist patients in a quick recovery.

Mesenteric Lymphatic Delivery of Oral Anticancer Tegafur by Emulsion Formulations (유제화에 의한 경구용 항암제인 테가푸르의 장관 임파수송)

  • Lee, Yong-Bok;Nam, Kweon-Ho;Chang, Woo-Ik;Oh, In-Joon;Koh, Ik-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 1995
  • W/O and O/W emulsions of tegafur (50 mg/5 ml/kg) were orally administered to rats to compare with their mesenteric lymphatic delivery effects. And also in order to demonstrate the lymph targeting associated to the oral route, it was deemed necessary to investigate the fate of solution after oral administration as a control. Lymph and plasma samples were periodically taken from each subject of mesenteric lymphatic duct cannulated rats. Then, lymph and plasma levels of tegafur and its active metabolite, 5-FU, were simultaneously observed. Also pharmacokinetic parameters were compared with each others. On the other hand, most previous studies of lymphatic transport have not addressed the question of whether an increase in mesenteric or thoracic lymph transport by the manipulation of a suspected variable was due to a selective delivery to the intestinal lymphatics or an overall increase availability. Therefore, based on a physiologically based pharmacokinetic model which represents the characteristics of lymphatic systems, we are also going to determine the contributions of mesenteric lymph transport versus thoracic lymph transport of tegafur reported in reference(13). In comparison with tegafur solution, AUC and mean residence time of plasma tegafur were significantly increased in W/O emulsion but significantly decreased in O/W emulsion. Lymph flow rates were similar in both solution and W/O emulsion but half in O/W emulsion. AUC of tegafur in mesenteric lymph and in plasma for W/O emulsion were 3.7 times and 2.9 times more than those for O/W emulsion, respectively. And AUC of 5-FU in thoracic lymph for W/O emulsion was 3.7 times more than that for O/W emulsion. These results suggested that lymphatic delivery or tegafur by W/O emulsion was more effective than that by on emulsion due to its differences or formation ability of chylomicrons.

  • PDF

Analysis of procedural performance after a pilot course on endovascular training for resuscitative endovascular balloon occlusion of the aorta

  • Sung Wook Chang;Dong Hun Kim;Dae Sung Ma;Ye Rim Chang
    • Journal of Trauma and Injury
    • /
    • v.36 no.1
    • /
    • pp.3-7
    • /
    • 2023
  • Purpose: As resuscitative endovascular balloon occlusion of the aorta (REBOA) is performed in an extremely emergent situation, achieving competent clinical practice is mandatory. Although there are several educational courses that teach the REBOA procedure, there have been no reports evaluating the impact of training on clinical practice. Therefore, this study is aimed to evaluate the effects of the course on procedural performance during resuscitation and on clinical outcomes. Methods: Patients who were managed at a regional trauma center in Dankook University Hospital from August 2016 to February 2018 were included and were grouped as precourse (August 2016-August 2017, n=9) and postcourse (September 2017- February 2018, n=9). Variables regarding injury, parameters regarding REBOA procedure, morbidity, and mortality were prospectively collected and reviewed for comparison between the groups. Results: Demographics and REBOA variables did not differ between groups. The time required from arterial puncture to balloon inflation was significantly shortened from 9.0 to 5.0 minutes (P=0.003). There were no complications associated with REBOA after the course. Mortality did not show any statistical difference before and after the course. Conclusions: The endovascular training for REBOA pilot course, which uses a modified form of flipped learning, realistic simulation of ultrasound-guided catheter insertion and balloon manipulation, and competence assessment, significantly improved procedural performance during resuscitation of trauma patients.

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

  • Wi, Jin-Hong;Joo, Hyun-Chel;Youn, Young-Nam;Song, Suk-Won;Kim, Tae Hoon;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.265-273
    • /
    • 2013
  • Background: The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic artery. Materials and Methods: Records of off-pump coronary artery bypass grafting with composite Y-grafts based on the left internal thoracic artery technique in 552 patients were analyzed retrospectively. After propensity score matching, 79 radial arterial (RA) composite grafts (RA group) and 79 saphenous vein composite grafts (SV group) were compared. The duration of mean follow-up was $24.6{\pm}14.6$ months (range, 1 to 55 months). Results: There were no differences in surgical mortality, all-cause mortality, or morbidity among the groups. Rates of 4-year survival were 91.7% and 96.3% in the RA and SV groups, respectively (p=0.519). The coronary reintervention-free survival rate and freedom from major adverse cardiovascular or cerebrovascular events were similar in the two groups (p=0.685, p=0.564). Conclusion: Construction of composite Y-grafts using the radial artery or saphenous vein showed similar mid-term results. Long-term follow-up and randomized trials will be needed to confirm our present conclusions.

First Results of the Single Heartstring Aortotomy for Multiple Off-Pump Vein Grafts: A Case Series

  • Santos, Rafael Freire dos;Niclauss, Lars
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.403-407
    • /
    • 2020
  • To validate the technique of the single Heartstring aortotomy for multiple off-pump venous bypass grafts (described in 2015), the results of a 38-month follow-up study of 18 patients, including high-risk patients, are presented. No early deaths or cardiac or cerebral complications occurred. During the follow-up period, 2 patients died of non-cardiac causes, and 3 developed coronary ischemia. Ischemia occurred due to late graft occlusion in 2 patients, both of whom had normal postoperative courses and correct graft flow. The presence of acute symptoms 24 months after surgery in these patients indicated that technical graft failure was unlikely. This safe technique combines the advantages of simple and reproducible revascularization, the off-pump approach, and minimal aortic manipulation.

Unilateral vocal cord paralysis after open heart surgery -A report of 2 cases- (개심술후 발생한 일측성 성대마비 -2례 보고-)

  • 이종욱
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.522-526
    • /
    • 1990
  • We have experienced 2 cases vocal cord paralysis after open heart surgery. One was a postoperatively developed right unilateral vocal cord paralysis after prosthetic mitral valve replacement with tricuspid valve annuloplasty. The other was a postoperative left unilateral vocal cord paralysis after prosthetic aortic and mitral valve replacement with tricuspid annuloplasty. They were intubated for forty-eight and seventy-two hours but after extubation complained of hoarseness, aphonia, anxiety, and ineffective coughing Indirect laryngoscopy performed at about postoperative one week, revealed partial paralysis and decreased mobility of the vocal cord. After active phonation therapy, symptoms were improved gradually and in the follow up indirect laryngoscopy, the vocal cord paralysis was improved. The symptoms were recovered completely at about postoperative one month in both. The cause of vocal cord paralysis after open heart surgery may be any retraction or stretching injury to the recurrent laryngeal nerve, especially right side, during median sternotomy retraction and open heart operation procedures. As a result, avoid of excessive spread of median sternotomy retractor and excessive manipulation and retraction of the heart during open heart procedures will reduce the occurrence of the vocal cord paralysis.

  • PDF

Left Atrium Rupture after Left Pneumonectiomy Using Autostapler -A Case Report- (자동봉합기를 이용한 전폐절제술후 발생한 좌심방 파열)

  • 배기만
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.418-421
    • /
    • 1994
  • The usage of autosuture instruments and techniques in resection of bronchovascular structures gained increasing acceptance amongst surgeons in the recent years. The manipulation of these devices are simple, safe, and shortens operating time by avoiding numerous ties and sutures. We have been using autosuture instruments in most of pulmonary resections in Yongdong Severance hospital, and had a satisfactory results. However, we recently have experienced post-pneumonectomy rupture of left pulmonary vein on postoperative one day where the rupture site was in the border of left atrium and left pulmonary vein where the stapler was fired. The patient underwent emergency operation to control massive bleeding and successfully managed by left atrial suture.

  • PDF

Effects of Manual Intervention and Self-Corrective Exercise Models of the General Coordinative Manipulation on Balance Restoration of Spine and Extremities Joints

  • Moon, Sang Eun;Kim, Mi Hwa
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.2
    • /
    • pp.573-587
    • /
    • 2013
  • The purpose of this study was conducted in order to analyze the effects of the manual intervention and self-corrective exercise models of general coordinative manipulation(GCM) on the balance restoration of spine & extremities joints with distortions and mal-alignment areas. The subjects were the members who visited GCM Musculoskeletal Prevent Exercise Center from March 1 2012 to December 31 2013 because of spine & extremities joints distortion and mal-alignments, poor posture, and body type correction. All subjects were diagnosed with the four types of the GBT diagnosis. And according to the standards of the mobility vs stability types of the upper & lower body, they were classified into Group 1(40 persons) and Group 2(24 persons). For every other day for three times a week, GCM intervention models were applied to all subjects for four weeks, adding up to 12 times in total. Then the balance restoration effects were re-evaluated with the same methods. The results are as follows. 1) Balance restoration effects of VASdp(Visual analysis scale pain & discomfort) and ER(Equilibrium reaction: ER) came out higher in GCM body type(GBT) II III IV of Group 1. 2) In case of balance restoration effects in Moire and postural evaluation areas, Group 1 was higher and cervical and scapular girdle were higher in Group 2. The balance restoration of the four GBT types was significant in all regions(p<.05), and the scapular girdle came out as high in the order of GBTII IV I. 3) In case of thoracic-lumbar scoliosis and head rotation facial asymmetric cervical scoliosis ribcage forward, the balance restoration effects of the upper body postural evaluation areas came out the highest in Group 1 and Group 2, respectively. The balance restoration effects of the four GBT types were significant in all regions(p<.05), and came out the highest in lumbar scoliosis GBTIII I, ribcage forward and thoracic scoliosis GBTII IV. 4) The balance restoration effects of the lower body postural evaluation areas came out higher in Group 1 and Group 2 for pelvis girdle deviation patella high umbilicus tilt and hallux valgus foot longitudinal arch: FLA patella direction, respectively. The balance restoration effects of the four GBT types were significant in all regions(p<.05), and came out the highest in pelvis girdle deviation GBTIII I and patella high-direction GBTIV II I. 5) The balance restoration effects between the same GBT came out significant (p<.05) in all evaluation areas and items. The conclusions of this study was the manual intervention and self-corrective exercise models of the GCM about the mal-alignment of the spine & extremities joints across the whole body indicated high balance restoration effects(p<.05) in spine & extremities joints in all evaluation areas.