Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

Treating a Ruptured Ascending Aorta with an Endovascular Stent Graft (상행 대동맥 파열에서 혈관내 스텐트 그라프트를 이용한 치료)

  • Kim, Gwan-Sic;Lee, Taek-Yeon;Kim, Joon-Bum;Lee, Seung-Hyun;Kim, Hee-Jung;Cho, Won-Chul
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.92-95
    • /
    • 2010
  • Endovascular stent grafting is regarded as a promising alternative approach to open surgical repair for treating various aortic diseases in high risk patients. We report here on a case of a 79-year-old female who underwent endovascular stent-graft insertion in the ascending aorta for treating a complicated ascending aortic rupture that occurred secondary to radiation necrosis during the treatment of recurrent breast cancer.

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.

Clinical Analysis of TEVAR in Blunt Thoracic Aortic Injury (둔상에 의한 흉부대동맥 손상에서 TEVAR에 관한 임상연구)

  • Ku, Gwan Woo;Choi, Jin Ho;Choi, Min Suk;Park, Sang Soon;Sul, Young Hoon;Go, Seung Je;Ye, Jin Bong;Kim, Joong Suck;Kim, Yeong Cheol;Hwang, Jung Joo
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.232-240
    • /
    • 2015
  • Purpose: Thoracic aortic injury is a life-threatening injury that has been traditionally treated by using surgical management. Recently, thoracic endovascular aortic repair (TEVAR) has been conducted pervasively as a better alternative treatment method. Therefore, this study will focus on analyzing the outcome of TEVAR in patients suffering from a blunt thoracic aortic injury. Methods: Of the blunt thoracic aortic injury patients admitted to Eulji University Hospital, this research focused on the 11 patients who had received TEVAR during the period from January 2008 to April 2014. Results: Seven of the 11 patients were male. At the time of admission, the mean systolic pressure was $105.64{\pm}24.60mm\;Hg$, and the mean heart rate was $103.64{\pm}20.02per$ minute. The median interval from arrival to repair was 7 (4, 47) hours. The mean stay in the ICU was $21.82{\pm}16.37hours$. In three patients, a chimney graft technique was also performed to save the left subclavian artery. In one patient, a debranching of the aortic arch vessels was performed. In two patients, the left subclavian artery was totally covered. In one patient whose proximal aortic neck length was insufficient, the landing zone was extended by using a prophylactic left subclavian artery to left common carotid artery bypass before TEVAR. There were no operative mortalities, but a patient who was covered of left subclavian artery died from ischemic brain injury. Complications such as migration, endovascular leakage, collapse, infection and thrombus did not occur. Conclusion: Our short-term outcomes of TEVAR for blunt thoracic aorta injury was feasible. Left subclavian artery may be sacrificed if the proximal landing zone is short, but several methods to continue the perfusion should be considered.

  • PDF

The Effect of Left Subclavian Artery Coverage During Endovascular Repair of the Thoracic Aortic Aneurysm on Cerebral Hemodynamics: Two Cases of Flow Measurement by using 2D Phase Contrast Magnetic Resonance Imaging (흉부대동맥류의 혈관내치료 도중 좌측 쇄골하동맥 폐색이 뇌혈류역동에 미치는 효과: 2차원 위상차 대조 자기공명영상을 이용한 혈류 측정 2례 보고)

  • Baek, Seung-Hoon;Youn, Sung-Won;Kim, Ho-Kyun;Kwon, Oh-Choon;Lee, Sub;Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • The proximity of thoracic aortic aneurysm to the left subclavian artery (LSA) has made the coverage of LSA during thoracic endovascular aortic repair (TEVAR) be essential. Despite controversy concerning the safety of LSA coverage and the indications for LSA revascularizations, the cerebral hemodynamic change after LSA coverage has not been demonstrated. We prospectively examined two patients who would undergo TEVAR with LSA coverage by using 2D cine phase contrast MR imaging. After LSA coverage, the left subclavian steal was properly compensated by the increased flow volumes of both carotid arteries and right vertebral artery, which is the major collateral supply. The total brain supply after TEVAR did not lessen, which showed good correlation with uneventful clinical outcome. Therefore, 2D phase contrast MR imaging can be recommended as a useful technique to evaluate the hemodynamic change of the LSA coverage during TEVAR and to triage the candidate for LSA revascularization.

A Right Intercosto-Bronchial Artery Derived from the Thyrocervical Trunk: An Unusual Cause of Type II Endoleak Post Thoracic Aortic Stenting

  • Choong, Andrew Mtl;Mitchell, Ken;Jenkins, Jason
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.139-141
    • /
    • 2015
  • The aetiology, incidence and management of type II endoleaks in standard infrarenal endovascular aortic aneurysm repair is well described. Far less data is available for thoracic stent grafting. We present a rare and interesting case of a type II endoleak post thoracic aortic stenting and highlight the aberrant anatomy that can cause this phenomenon in such cases.

Recurrent Aortobronchial Fistula after Endovascular Stenting for Infected Pseudoaneurysm of the Proximal Descending Thoracic Aorta: Case Report

  • Lee, Sun-Geun;Lee, Seung Hyong;Park, Won Kyoun;Kim, Dae Hyun;Song, Jae Won;Cho, Sang-Ho
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.425-428
    • /
    • 2021
  • Aortobronchial fistula (ABF) induced by an infected pseudoaneurysm of the thoracic aorta is a life-threatening condition. As surgical treatment is associated with significant mortality and morbidity, thoracic endovascular aneurysm repair (TEVAR) may be an alternative for the treatment of ABF. However, the long-term durability of this intervention is largely unknown and the recurrence of ABF is a potential complication. We experienced a case of recurrent ABF after stent grafting as an early procedure for an infected pseudoaneurysm of the thoracic aorta. Remnant ABF, bronchial and/or aortic wall erosion, vasa vasorum connected with ABF, and recurrent local inflammation of the thin aortic wall around ABF might cause recurrent hemoptysis. As a result, we suggest that TEVAR should be considered as a bridge therapy for the initial treatment of ABF resulting from an infected pseudoaneurysm, and that several options, such as second-stage surgery, should be considered to prevent the recurrence of ABF.

Chylothorax after Blunt Chest Trauma: A Case Report

  • Sriprasit, Pawit;Akaraborworn, Osaree
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.407-410
    • /
    • 2017
  • Traumatic chylothorax after blunt chest trauma alone is considered rare. Our patient was a 27-year-old female who was in a motorcycle accident and sustained blunt thoracic and traumatic thoracic aortic injuries with T1-T2 vertebral subluxation. She underwent thoracic endovascular aortic repair from T4 to T9 without any thoracic or spinal surgery. On postoperative day 7, the drainage from her left chest turned into a milky-white fluid indicative of chyle leakage. The patient was treated conservatively for 2 weeks and then the chest drain was safely removed. The results show that traumatic chylothorax can be successfully managed with conservative treatment.

Hybrid Approach for Treatment of Multiple Traumatic Injuries of the Heart, Aorta, and Abdominal Organs

  • Kim, Seon Hee;Song, Seunghwan;Cho, Ho Seong;Park, Chan Yong
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.372-375
    • /
    • 2019
  • A 55-year-old man was admitted to the trauma center after a car accident. Cardiac tamponade, traumatic aortic injury, and hemoperitoneum were diagnosed by ultrasonography. The trauma surgeon, cardiac surgeon, and interventional radiologist discussed the prioritization of interventions. Multi-detector computed tomography was carried out first to determine the severity and extent of the injuries, followed by exploratory sternotomy to repair a left auricle rupture. A damage control laparotomy was then performed to control mesenteric bleeding. Lastly, a descending thoracic aorta injury was treated by endovascular stenting. These procedures were performed in the hybrid-angio room. The patient was discharged on postoperative day 135, without complications.