• 제목/요약/키워드: Thompson-Lampard theorem

검색결과 4건 처리시간 0.02초

Thompson-Lampard 정리를 적용한 마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발 (Development of a Non-contacting Capacitive Sensor Based on Thompson-Lampard Theorem for Measurement of ${\mu}m-order$ Displacements)

  • 김한준;강전홍;한상옥
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권9호
    • /
    • pp.443-448
    • /
    • 2006
  • Non-contacting capacitive sensor based on Thompson-Lampard theorem have been fabricated and characterized for measuring of 때 order displacements. To overcome disadvantages of the existed capacitive sensors of parallel plate type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes with a constant gap of 0.2mm between the electrodes. Two of the electrodes were used as a high potential electrode and a low one, the other two electrodes were used as guard electrodes. These electrodes were made from copper using RF sputtering system on a sapphire plate with diameter 17 mm and thickness 0.7 mm. This sensor can be used for measuring the distance not only between the sensor and metallic target connected to ground potential but also non-metallic target without ground connection.

Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안 (A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance)

  • 김한준;이래덕;강전흥;유광민;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

Cross Capacitance 측정법을 이용한 유전상수 정밀측정 (Precise Measurement of Dielectric Constant Using Cross Capacitance Measurement Method)

  • 김한준;강전홍;유광민;이세현;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1287-1288
    • /
    • 2007
  • The cross capacitor electrode system applied Thompson-Lampard theorem for precise and accurate measurement of dielectric constants is studied in this study. The capacitance derived from cross capacitor is calculated by the equation of ($C=\frac{{\epsilon}ln2}{\pi}{\cdot}$ effectivelength of electrode) which is very different from the equation of capacitance derived from parallel plate capacitor. From above mentioned reason, the capacitance measurement uncertainty of cross capacitor can be reduced then that of the parallel plate capacitor. the measurement dielectric constant measured by cross capacitor electrode method is one order more accurate and precise than that of 3-electrode method.

  • PDF

비접촉식 4-전극형 전기용량 센서를 이용한 in situ 정밀측정 (Precision in situ Measurement using Non-Contacting Capacitive Sensor with 4-Electrodes)

  • 김재열;이래덕;박기형;마상동;양동조
    • 한국정밀공학회지
    • /
    • 제19권3호
    • /
    • pp.33-38
    • /
    • 2002
  • To establish the national standard of capacitance, four main electrodes of the cross capacitor which were evaluated to linearity and roundness less the $\pm 1 \mu m$ respectively have to be adjusted symmetrically in an inner cylinder. Four LM shafts with diameter of 5 mm were installed between main electrodes of the cross capacitor, and the electrodes were adjusted, as the first step, by means of the measured capacitance. In the second step, the symmetrical adjustment up to $\pm 1.2\mu m$ was performed by using a ball sensor, ball-type movable sensor, non-contacting capacitive sensor and upper guard sensor which were developed in this project.