• Title/Summary/Keyword: Thomas method

Search Result 180, Processing Time 0.027 seconds

The Biodegradation Characteristics of the Mixtures of Bunker-A, B Oils with Dispersants in the Seawater

  • BAEK Joong-Soo;KIM Gwang-Su;CHO Eun-il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.6
    • /
    • pp.787-796
    • /
    • 1996
  • The biodegradation experiment, the TOD analysis and the element analysis for dispersant, Bunker-A oil and Bunker-B oil were conducted to study the biodegradation characteristics of a mixture of Bunker-A oil with dispersant and a mixture of Bunker-B oil with dispersant in the seawater. The results of biodegradation experiment showed 1mg of dispersant to be equivalent to 0.26 mg of $BOD_5$ and to 0.60 mg of $BOD_{20}$ in the natural seawater. The results of TOD analysis showed each 1 mg of dispersant, Bunker-A oil and Bunker-B oil to be equivalent to 2.37 mg, 2.94 mg and 2.74 mg of TOD, respectively. The results of element analysis showed carbon, hydrogen, nitrogen and phosphorus contents of dispersant to be $82.1\%,\;13.8\%,\;1.8\%\;and\;2.2\%$, respectively. Carbon and hydrogen contents of Bunker-A oil were found to be $73.3\%\;and\;13.5\%$, respectively, and carbon, hydrogen and nitrogen contents of Bunker-B oil to be $80.4\%,\;12.3\%\;and\;0.7\%$, respectively. Accordingly, the detection of nitrogen and phosphorus in dispersant shows that dispersants should be used with caution in coastal waters, with relation to eutrophication. The biodegradability of dispersant expressed as the ratio of $BOD_5/TOD$ was found to be $11.0\%$. As the mix ratios of dispersant to Bunker-A oil (3 mg/l) and a mixture of Bunker-B oil (3mg/l) were changed from 1 : 10 to 5 : 10, the biodegradabilities of a mixture of Bunker-A oil with dispersant and Bunker-B oil with dispersant increased from $2.1\%\;to\;7.2\%$ and from $1.0\%\;to\;4.4\%$, respectively. Accordingly, the dispersant belongs to the organic matter group of middle-biodegradability while mixtures in the mix ratio range of $1:10\~5:10$ belong to the organic matter group of low-biodegradability. The deoxygenation rate constant $(K_1)$ and ultimate biochemical oxygen demand $(L_0)$ obtained from the biodegradation experiment and Thomas slope method were found to be 0.125/day and 2.487 mg/l for dispersant (4 mg/l), respectively. $K_1\;and\;L_0$, were found to be $0.079\~0.131/day$ and $0.318\~2.052\;mg/l$ for a mixture of Bunker-A oil with dispersant and to be $0.106\~0.371/day$ and $0.262\~1.106\;mg/l$ for a mixture of Bunker-B oil with dispersant, respectively, having $1:10\~5:10$ mix ratios of dispersant to Bunker-A oil and Bunker-B oil. The ultimate biochemical oxygen demands of the mixtures increased as the mix ratio of dispersant to Bunker-A, B oils changed from 1 : 10 to 5 : 10. This suggests that the more dispersants are applied to the sea for the cleanup of Bunker-A oil or Bunker-B oil, the more decreases the dissolved oxygen level in the seawater.

  • PDF

Role of Blood Flow vs. $O_{2}$ Consumption in Nicotinamide-induced Increase $pO_{2}$ in a Murine Tumor (Nicotinamide에 의한 종양내 산소 분압의 증가에 있어서 혈류 또는 산소 소모의 역할)

  • Lee Intae;Demhartner Thomas J.;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.17-25
    • /
    • 1994
  • We evaluated the effect of nicotinamide on cellular $O_{2}$ consumption and metabolic status i.e., adenylate phosphates and $NAD^{+}$in-vitro, and changes in blood flow in-vivo, to determine whether changes in cellular metabolism or increased oxygen availability, was responsible for increased tumor oxygenation. Thirty min, pre-incubation of cells with$\∼$4mM (= 500mg/kg) nicotinamide resulted in no change in cellular $O_{2}$ consumption. Similarly neither the adenylate Phosphates nor the cellular $NAD^{+}$levels were altered in the presence of $\∼$4mM nicontinamide. In-vivo, nicotinamide (500mg/kg) increased $O_{2}$ availability as estimated by changes in relative tumor blood flow (RBC flux). The changes in RBC flux measured by the laser Doppler method, were tumor volume dependent and increased from$\∼$35$ \% $ in$\∼$ 150$mm_{3}$tumors to$\∼$~75$ \% $ in$\∼$500$mm^{3}$ tumors. In conclusion, these observations indicate a reduction in local tissue $O_{2}$ consumption is not a mechanism of improved tumor oxygenation by nicotinamide in FSa II murine tumor model. The primary mechanism of increased $pO_{2}$ appears to be an increased local tumor blood flow.

  • PDF

A Statistical Study Evaporation tn DAEGU Area (대구지방의 증발량에 대한 통계학적 연구)

  • 김영기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.4
    • /
    • pp.3160-3169
    • /
    • 1973
  • Rainfall, evaporation, and permeability of water are the most important factors in determining the demand of water. The Daegu area has only a meteorologi observatory and there is not sufficient data for adapting the advanced method for derivation of the estimated of evaporation in the Daegu area. However, by using available data, the writer devoted his great effort in deriving the most reasonable formula applicable to the Daegu area and it is adaptable for various purposes such as industry and estimation of groundwater etc. The data used in this study was the monthly amount of evaporation of the Daegu area for the past 13 years(1960 to 1970). A year can be divided into two groups by relative degrees of evaporation in this area: the first group (less evaporation) is January, February, March, October, November, and December, and the second (more evaporation) is April, May, June, July, August, and September. The amount of evaporation of the two groups were statistically treated by the theory of probability for derivation of estimated formula of evaporation. The formula derved is believed to fully consider. The characteristic hydrological environment of this area as the following shows: log(x+3)=0.8963+0.1125$\xi$..........(4, 5, 6, 7, 8, 9 month) log(x-0.7)=0.2051+0.3023$\xi$..........(1, 2, 3, 10, 11, 12 month) This study obtained the above formula of probability of the monthly evaporation of this area by using the relation: $F_(x)=\frac{1}{{\surd}{\pi}}\int\limits_{-\infty}^{\xi}e^{-\xi2}d{\xi}\;{\xi}=alog_{\alpha}({\frac{x_0+b'}{x_0+b})\;(-b<x<{\infty})$ $$log(x_0+b)=0.80961$ $$\frac{1}{a}=\sqrt{\frac{2N}{N-1}}\;Sx=0.1125$$ $$b=\frac{1}{m}\sum\limits_{i-I}^{m}b_s=3.14$$ $$S_x=\sqrt{\frac{1}{N}\sum\limits_{i-I}^{N}\{log(x_i+b)\}^2-\{log(x_i+b)\}^2}=0.0791$$ (4, 5, 6, 7, 8, 9 month) This formula may be advantageously applied to estimation of evaporation in the Daegu area. Notation for general terms has been denoted by following: $W_(x)$: probability of occurance. $$W_(x)=\int_x^{\infty}f(x)dx$$ P : probability $$P=\frac{N!}{t!(N-t)}{F_i^{N-{\pi}}(1-F_i)^l$$ $$F_{\eta}:\; Thomas\;plot\;F_{\eta}=(1-\frac{n}{N+1})$$ $X_l\;X_i$: maximun, minimum value of total number of sample size(other notation for general terms was used as needed)

  • PDF

Experimental Study on the Fire Performance of PC Slab by the Bearing Length (걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구)

  • Park, Siyoung;Kang, Thomas H.K.;Lee, Ho-Wook;Gwak, Si-Young;Park, Jun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.14-22
    • /
    • 2022
  • In this study, a fire test was conducted to evaluate the fire performance of precast concrete (PC) slabs in an outdoor environment in response to the increase in fire incidents caused by the growth of warehouses. Prior to the field fire test, the tensile yield strength of the tendon at elevated temperatures was tested to analyze the mechanical properties. Also, by referring to previous studies, the thermal properties of tendon and the mechanical and thermal properties of concrete were investigated. A field fire test was conducted to analyze the structural and fire performance of two identical slabs with 50 and 150 mm bearing length. As the bearing length increased, deflection and horizontal displacement decreased. The fire test lasted for 200 minutes without the collapse of slabs, validating current codes. Based on the structural performance which maintained even with concrete spalling and rupture of some tendons, the bonded method is assumed to be practical in pre-tensioned PC slabs. The results of fire test are expected to be utilized in evaluating the fire performance of PC slabs in warehouses.

Comparison of behavior of high-rise residential buildings with and without post-tensioned transfer plate system

  • Byeonguk Ahn;Fahimeh Yavartanoo;Jang-Keun Yoon;Su-Min Kang;Seungjun Kim;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • v.31 no.4
    • /
    • pp.337-348
    • /
    • 2023
  • Shear wall is commonly used as a lateral force resisting system of concrete mid-rise and high-rise buildings, but it brings challenges in providing relatively large space throughout the building height. For this reason, the structure system where the upper structure with bearing, non-bearing and/or shear walls that sits on top of a transfer plate system supported by widely spaced columns at the lower stories is preferred in some regions, particularly in low to moderate seismic regions in Asia. A thick reinforced concrete (RC) plate has often been used as a transfer system, along with RC transfer girders; however, the RC plate becomes very thick for tall buildings. Applying the post-tensioning (PT) technique to RC plates can effectively reduce the thickness and reinforcement as an economical design method. Currently, a simplified model is used for numerical modeling of PT transfer plate, which does not consider the interaction of the plate and the upper structure. To observe the actual behavior of PT transfer plate under seismic loads, it is necessary to model whole parts of the structure and tendons to precisely include the interaction and the secondary effect of PT tendons in the results. This research evaluated the seismic behavior of shear wall-type residential buildings with PT transfer plates for the condition that PT tendons are included or excluded in the modeling. Three-dimensional finite element models were developed, which includes prestressing tendon elements, and response spectrum analyses were carried out to evaluate seismic forces. Two buildings with flat-shape and L-shape plans were considered, and design forces of shear walls and transfer columns for a system with and without PT tendons were compared. The results showed that, in some cases, excluding PT tendons from the model leads to an unrealistic estimation of the demands for shear walls sit on transfer plate and transfer columns due to excluding the secondary effect of PT tendons. Based on the results, generally, the secondary effect reduces shear force demand and axial-flexural demands of transfer columns but increases the shear force demand of shear walls. The results of this study suggested that, in addition to the effect of PT on the resistance of transfer plate, it is necessary to include PT tendons in the modeling to consider its effect on force demand.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

Anomaly Detection for User Action with Generative Adversarial Networks (적대적 생성 모델을 활용한 사용자 행위 이상 탐지 방법)

  • Choi, Nam woong;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.3
    • /
    • pp.43-62
    • /
    • 2019
  • At one time, the anomaly detection sector dominated the method of determining whether there was an abnormality based on the statistics derived from specific data. This methodology was possible because the dimension of the data was simple in the past, so the classical statistical method could work effectively. However, as the characteristics of data have changed complexly in the era of big data, it has become more difficult to accurately analyze and predict the data that occurs throughout the industry in the conventional way. Therefore, SVM and Decision Tree based supervised learning algorithms were used. However, there is peculiarity that supervised learning based model can only accurately predict the test data, when the number of classes is equal to the number of normal classes and most of the data generated in the industry has unbalanced data class. Therefore, the predicted results are not always valid when supervised learning model is applied. In order to overcome these drawbacks, many studies now use the unsupervised learning-based model that is not influenced by class distribution, such as autoencoder or generative adversarial networks. In this paper, we propose a method to detect anomalies using generative adversarial networks. AnoGAN, introduced in the study of Thomas et al (2017), is a classification model that performs abnormal detection of medical images. It was composed of a Convolution Neural Net and was used in the field of detection. On the other hand, sequencing data abnormality detection using generative adversarial network is a lack of research papers compared to image data. Of course, in Li et al (2018), a study by Li et al (LSTM), a type of recurrent neural network, has proposed a model to classify the abnormities of numerical sequence data, but it has not been used for categorical sequence data, as well as feature matching method applied by salans et al.(2016). So it suggests that there are a number of studies to be tried on in the ideal classification of sequence data through a generative adversarial Network. In order to learn the sequence data, the structure of the generative adversarial networks is composed of LSTM, and the 2 stacked-LSTM of the generator is composed of 32-dim hidden unit layers and 64-dim hidden unit layers. The LSTM of the discriminator consists of 64-dim hidden unit layer were used. In the process of deriving abnormal scores from existing paper of Anomaly Detection for Sequence data, entropy values of probability of actual data are used in the process of deriving abnormal scores. but in this paper, as mentioned earlier, abnormal scores have been derived by using feature matching techniques. In addition, the process of optimizing latent variables was designed with LSTM to improve model performance. The modified form of generative adversarial model was more accurate in all experiments than the autoencoder in terms of precision and was approximately 7% higher in accuracy. In terms of Robustness, Generative adversarial networks also performed better than autoencoder. Because generative adversarial networks can learn data distribution from real categorical sequence data, Unaffected by a single normal data. But autoencoder is not. Result of Robustness test showed that he accuracy of the autocoder was 92%, the accuracy of the hostile neural network was 96%, and in terms of sensitivity, the autocoder was 40% and the hostile neural network was 51%. In this paper, experiments have also been conducted to show how much performance changes due to differences in the optimization structure of potential variables. As a result, the level of 1% was improved in terms of sensitivity. These results suggest that it presented a new perspective on optimizing latent variable that were relatively insignificant.

Study on the Biodegradability of Dispersants and Dispersant/Bunker-C Oil Mixtures and the Dissolved Oxygen Consumption in the Seawater(I) - The Biodegradability of Dispersants and the Dissolved Oxygen Consumption in the Seawater - (해수중에서 유처리제 및 유처리제/Bunker-C유 혼합물의 생분해도와 용존산소소비에 관한 연구(I) - 유처리제의 생분해도와 용존산소소비 -)

  • KIM Gwang-Su;PARK Chung-Kil;YOU Sun-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.5
    • /
    • pp.493-501
    • /
    • 1993
  • As the dispersants and the dispersant/oil mixtures are degraded naturally by the microorganisms in the seawater, the consumption of dissolved oxygen may cause marine organisms to be damaged especially in the waters where the dissolved oxygen level is low due to the pollution and the restriction of seawater flow. The biodegradation experiment, the TOD analysis and the element analysis for three dispersants(SG, GL and WC) and a nonionic surfactant(OA-5) were conducted for the purposes of evaluating the biodegradability of dispersants and studying the effect of dispersants on dissolved oxygen in the seawater. The results of biodegradation experiment showed 1mg of dispersants to be equivalent to $0.403{\sim}0.595mg$ of $BOD_5$ and to $0.703{\sim}0.855mg$ of $BOD_{20}$, and 1mg of nonionic surfactant to be equivalent to 0.50mg of $BOD_5$ and to 0.97mg of $BOD_{20}$ in the natural seawater. The results of TOD analysis showed 1mg of dispersants to be $2.37{\sim}2.80mg$ of TOD and 1mg of nonionic surfactant to be 2.45mg of TOD. The results of element analysis showed carbon content and hydrogen content to be $67.6{\sim}76.5\%$ and $10.2{\sim}12.2\%$ for dispersants, and $65.3\%$ and $10.3\%$ for nonionic surfactant, respectively. No nitrogen element was detected in dispersants and a nonionic surfactant. The biodegradability of dispersants shown as the ratio of $BOD_5/TOD$ was found to be in the range of $17{\sim}21\%$, and that of nonionic surfactant was found to be about $20\%$. This means that dispersants and nonionic surfactant belong in the organic matter group of middle-biodegradabilily. The deoxygenation rates($K_1$) and ultimate oxygen demands($L_o$) obtained through the biodegration experiment and Thomas slope method were found to be $0.121{\sim}0.171/day$ and $3.155{\sim}3.810mg/l$ for 4mg/l of dispersants and to be 0.181/day and 1.911mg/l for 2mg/l of nonionic surfactant in the seawater, respectively.

  • PDF

Study on the Biodegradability of Dispersants and Dispersant/Bunker-C Oil Mixtures and the Dissolved Oxygen Consumption in the Seawater(II) - The Biodegradability of Dispersant/Bunker-C Oil Mixtures and the Dissolved Oxygen Consumption in the Seawater - (해수중에서 유처리제 및 유처리제/Bunker-C유 혼합물의 생분해도와 용존산소소비에 관한 연구(II) - 유처리제/Bunker-C유 혼합물의 생분해도와 용존산소소비 -)

  • KIM Gwang-Su;PARK Chung-Kil;KIM Jong-Gu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.6
    • /
    • pp.519-528
    • /
    • 1993
  • The biodegradation experiment, the TOD analysis and the element analysis for dispersant, Bunker-C and dispersant/Bunker-C oil mixtures were conducted for the purposes of evaluating the biodegradability of dispersnat/Bunker-C oil mixtures and studying the consumption of dissolved oxygen with relation to biodegradation in the seawater. The results of biodegradation experiment showed the mixtures with $1:10{\sim}5:10$ mix ratios of dispersant to 4mg/l of Bunker-C oil to be $0.34{\sim}2.06mg/l$ of $BOD_5$ and to be $1.05{\sim}5.47mg/l$ of $BOD_{20}$ in natural seawater. The results of TOD analysis showed 1mg of Bunker-C oil to be 3.16mg of TOD. The results of element analysis showed the contents of carbon and hydrogen to be $87.3\%\;and\;11.5\%$ for Bunker-C oil, respectively, but nitrogen element was not detected in Bunker-C oil. The biodegradability of dispersant/Bunker-C oil mixture shown as the ratio of $BOD_5$/TOD was increased from $3\%\;to\;11\%$ as a mix ratio of dispersant to 4mg/l of Bunker-C oil changed from 1:10 to 5:10, and the mixtures were found to belong in the organic matter group of low-biodegradability. The deoxygenation rates($K_1$) and ultimate oxygen demands($L_o$) obtained through the biodegration experiment and Thomas slope method were found to be $0.072{\sim}0.097/day$ and $1.113{\sim}6.746mg/l$ for the mixtures with $1:10{\sim}5:10$ mix ratios of dispersant to 4mg/l of Bunker-C oil, respectively. The ultimate oxygen demand of mixture was increased as a mix ratio of dispersant to Bunker-C oil changed from 1:10 to 10:5. This means that the more dispersants are applied to the sea for Bunker-C oil cleanup, the more decreases the dissolved oxygen level in the seawater.

  • PDF

A PRELIMINARY STUDY OF RELATIONSHIP AMONG TEMPERAMENTAL CHARACTERISTICS, FAMILY ENVIRONMENT AND DEVELOPMENTAL HISTORY (기질과 가정환경 및 발달사이의 관계에 관한 예비연구)

  • Hong, Sung-Do
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.50-56
    • /
    • 1997
  • The objective of this study was to compare the family environment and developmental history of three groups of children classified by their temperament. The parents of 484 Korean children aged between 3 and 7 years completed the Korean version of Parental Temperamental Questionnaire developed by Thomas and Chess and Developmental Questionnaire created by Division of Child and Adolescent Psychiatry, Samsung Medical Center. After clustering these children into 5 temperamental groups according to the method proposed by Fullard et al, 98 Easy, 36 Difficult, and 21 Slow-To-Warm-Up children were included in the analysis. Statistically meaningful differences observed among three groups were as follow:1) Marital conflict of parents was more frequent in Difficult and Slow-To-Warm-Up children than in Easy children. 2) Parentchild conflict was more frequent in Difficult children than in Easy children. 3) Conflict among siblings was more frequent in Difficult children than in Easy children. 4) Average monthly income of family was less in Difficult children than in Easy children. 5) Toilet training was achieved later in Difficult children than in Easy children. 6) Motor development was slower, between 2 and 5 years old, in Slow-To-Warm-Up children than in Easy children. 7) Fear of stranger started earlier in Slow-To-Warm-Up children than in easy children. 8) Physical health was poorer in Difficult and Slow-To-Warm-Up children than in easy children. The findings indicate that Difficult child or Slow-To-Warm-Up child group have unfavorable family environment, different developmental milestone and poorer physical health in comparison with Easy child group.

  • PDF