• 제목/요약/키워드: Thin-section

Search Result 596, Processing Time 0.025 seconds

Do Paneth Cells Regulate the Zinc Body Burden? (Zinc 대사와 관련된 Paneth 세포활성의 변화에 관한 조직화학적 연구)

  • Jo, Seung-Mook;Kim, Sung-Jun;Park, Seung-Kook;Kang, Tae-Cheon;Won, Moo-Ho
    • Applied Microscopy
    • /
    • v.30 no.4
    • /
    • pp.357-365
    • /
    • 2000
  • Paneth cells have been suggested to contribute to the elimination of excess metals into the intestinal lumen. The purpose of this study wat to investigate the changes of the zinc pools in rats subjected to functional loading with zinc salt by mean of both light and electron microscopical autometallography (AMG). Wistar rats 4 were administrated with zinc chloride (20 mg/kg body weight) intraperitoneally dissolved in 1 ml distilled water. The control group received 1 ml saline IP. After further one hour the animals were transcardially perfused with 0.4% sodium sulphide dissolved in 0.1 M PB fellowed by 3% glutaraldehyde solution for 10 minutes. Pieces of ileum were frozen with solid $CO_2$ and sectioned on a cryostat. The sections $(20{\mu}m)$ were autometallographically developed. Sections selected for EM were reembedded on top of a blank Epon block, from which ultrathin sections (100 nm) were cut. The ultrathin sections were double stained with uranyl acetate (30 min) and lead citrate (5 min), then examined under electron microscope. Studies of comparable sections from control and zinc loaded animals with the AMG selenium method gave quite different results. The control animals demonstrated a weakly positive staining in the cytoplasm of the Paneth cells. In the electron microscope the AMG silver grains were found to be located in the cytoplasm, while the electron dense secretary granules and other cell organelles were void of staining. Few AMG grains were located at the apical surface of the Paneth cells. In sections from zinc loaded rats, the AMG grains were seen in abundance in the lumen of the Lieberkuhn crypts at light microscopic levels. At EM levels the zinc revealing silver grains were located in the cytoplasm as in the controls, but much more AMG grains were shifted into the secretary granules. Furthermore, profound AMG grains were found in the lumen of the crypts and surrounding vessels. And a few grains were seen in the endothelium. The AMG technique demonstrated a pattern of AMG grains in the Paneth cells that strongly suggests a transport of zinc ions through these cells.

  • PDF

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF

Diagnostic Value of Transbronchial Lung Biopsy -Including Diagnostic Yield According to Tumor-bronchus Relationship- (경기관지폐생검의 진단적 가치 -병변과 기관지의 관계에 따른 진단율을 포함한 연구-)

  • Kang, Tae-Kyong;Cha, Seung-Ick;Park, Jae-Yong;Chae, Sang-Chul;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.438-447
    • /
    • 2000
  • Background : Transbronchial lung biopsy (TBLB) is a relatively simple and convenient procedure to obtain lung tissue from a patient with diffuse or localized lesion on chest radiographs, whose disease cannot be diagnosed through routine tests. The authors tried to evaluate the diagnostic value of TBLB, especially, the concordance between CT scan and TBLB with respect to the location of the lesion and diagnostic yield according to tumor-bronchus relationship. Method : We reviewed the medical records, plain chest films, and chest CT scans of 278 patients who underwent TBLB at Kyungpook National University Hospital between January 1996 and June 1998. Results : One hundred and sixteen (41.7 %) patients were diagnosed by TBLB. Diagnostic yield of TBLB of malignant tumors tended to be higher than that of benign diseases (64.7% versus 53.9%, p=0.09). Of primary lung cancers, TBLB was more diagnostic in adenocarcinoma and small-cell carcinoma than other cell types (p<0.01) and, of benign diseases, more diagnostic in tuberculosis than in non-tuberculous diseases (p<0.05). There was no significant difference in the diagnostic rate according to the location of the tumor. The diagnostic rate tended to increase with the size of tumor (p=0.06). The diagnootic rate of TBLB did not differ according to the pattern of lesion in benign diseases. However, in malignant diseases TBLB was more diagnostic in diffuse/multiple nodular lesions than in localized lesions(p<0.05). According to the tumor-bronchus relationship, TBLB was more diagnootic in type I/II groups than in other types. CT scan and TBLB showed a strong correlation with respect to the localization of the lesion (r=0.994, p<0.01). Conclusion : The above results show that TBLB is useful in the diagnosis of lung disease. CT scan and TBLB showed a strong correlation in determining the location of the lesion. Diagnostic yield of TBLB is higher in lesions with 'bronchus sign' (type I and II). TBLB and other diagnootic methods such as transthoracic needle aspiration are expected to complement one another in the diagnosis of lung diseases.

  • PDF

Evaluation for Rock Cleavage Using Distribution of Microcrack Lengths and Spacings (1) (미세균열의 길이 및 간격 분포를 이용한 결의 평가(1))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.45-54
    • /
    • 2017
  • The characteristics of the rock cleavage in Jurassic Geochang granite were analysed using the distribution of microcrack lengths and spacings. The phases of distribution of the above lengths and spacings were derived from the enlarged photomicrographs(${\times}6.7$) of the thin section. First, the length and spacing-cumulative diagrams for the six directions of rock cleavages were arranged in increasing order($H2{\rightarrow}R1$) on the density(${\rho}$) of microcrack length. The various parameters were extracted through the combination of the above two types of diagrams. The discrimination factors representing the three quarrying planes and three rock cleavages were acquired through the mutual contrast between the values of parameters. The analysis results of the research are summarized as follows. The evaluation for the six directions of rock cleavages was performed using the parameters such as (1) intersection angle(${\alpha}-{\beta}$) and (2) exponent difference(${\lambda}_S-{\lambda}_L$) between two exponential straight lines related to spacing(${\alpha}$, ${\lambda}_S$) and length(${\beta}$, ${\lambda}_L$). The values of parameters(1 and 2) are in order of H(hardway, (H1 + H2)/2) < G(grain, (G1 + G2)/2) < R(rift, (R1 + R2)/2). On the contrary, the values of the above two parameters for three planes are in order of R < G < H. Meanwhile, the direction of convergence between two exponential straight lines was derived. The above direction is compliant to arrangement of the line os' centering around the line ol. The above two lines converge in the direction of the Y-axis when the line ol and line os' occupy the upper region on the left and the lower region on the right, respectively(R-type). On the contrary, the above two lines converge in the direction of the X-axis when the order of arrangement between line ol and line os' is reversed(H-type). Especially, the positive(+) or negative(-) value of intersection angle(${\alpha}-{\beta}$) is determined by the arrangement of two vertical lines. This type of correlation analysis is useful for evaluating the relative strength of rock cleavage and discriminating three quarrying planes.

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (V) (미세균열의 간격 분포를 이용한 결의 평가(V))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2017
  • Jurassic granite from Geochang was analysed with respect to the characteristics of the rock cleavage. The comprehensive evaluation for rock cleavages was performed through the combination of the 16 parameters derived from the enlarged photomicrographs of the thin section and the spacing-cumulative frequency diagrams. The results of analysis for the representative values of these spacing parameters with respect to the rock cleavage are summarized as follows. First, the above parameters can be classified into group I (spacing frequency (N), total spacing ($1m{\geq}$), constant (a), exponent (${\lambda}$), slope of exponential straight line (${\theta}$), length of line (oa') and trigonometric ratios ($sin{\theta}$, $tan{\theta}$) and group II (mean spacing (Sm), difference value between mean spacing and median spacing (Sm-Sme), density (${\rho}$), lengths of lines (oa and aa'), area of a right-angled triangle (${\Delta}oaa^{\prime}$) and trigonometric ratio($cos{\theta}$). The values of the 8 parameters belonging to group I show an order of H(hardway, H1+H2)

Evaluation for Rock Cleavage Using Distribution of Microcrack Lengths (미세균열의 길이 분포를 이용한 결의 평가)

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.165-180
    • /
    • 2015
  • Jurassic granite from Geochang was analysed with respect to the characteristics of the rock cleavage. The phases of distribution of microcracks were well evidenced from the enlarged photomicrographs(${\times}6.7$) of the thin section. In this study, the length - cumulative frequency diagrams were used for expressing the distribution characteristics of microcrack. The diagrams for the six directions were arranged in the magnitude of density(${\rho}$). These diagrams show an order of H2 < H1 < G2 < G1 < R2 < R1 from the related chart. Among six diagrams, the diagram for hardway 2(H2) occupies the lowermost region on the left. On the contrary, the diagram for rift 1(R1) occupies the uppermost region on the right. Curve patterns of the two diagrams change from uniform to exponential distribution type in accordance with the increased density. The overall distribution characteristics of the diagrams were well evidenced from the magnitude of the exponent(${\lambda}$) and length of line oa related to the exponential straight line. The magnitude of exponent governing the values of slope(${\theta}$) is inversely proportional to the values of microcrack parameters such as number(N), length(L) and density. On the contrary, length of line oa is directly proportional to the values of the above three parameters. Above microcrack parameters related to the order of arrangement of diagrams show an order of hardway(H1 + H2) < grain(G1 + G2) < rift(R1 + R2). The distribution characteristics of progressive variation are found among the six diagrams. The order of arrangement of the diagrams indicates a relative magnitude of the rock cleavage. Meanwhile, the parameters such as slope, exponent, density and length of line oa were arranged in an order of H2 < H1 < G2 < G1 < R2 < R1. The variation curves of a smooth quadratic function are shown from the related chart. From the correlation chart between density and the above parameters, a common regularity following power-law correlation function was derived. Finally, the analysis for the rock cleavage was conducted through the combination between the diagram and microcrack parameter. This type of combination contribute to the progressivity in evaluation for the rock cleavage.

Evaluation for Rock Cleavage Using Distribution of Microcrack Spacings (I) (미세균열의 간격 분포를 이용한 결의 평가(I))

  • Park, Deok-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.13-27
    • /
    • 2016
  • The characteristics of the rock cleavage inherent in Jurassic granite from Geochang were analysed. The phases of distribution of microcrack spacings were derived from the enlarged photomicrographs(${\times}6.7$) of the thin section. The evaluation for the six directions of rock cleavages was performed using nine parameters such as (1) frequency of microcrack spacing(N), (2) frequency ratio(${\leq}1mm$ and 4 mm >) to total spacing frequency(N:191), (3) spacing ratio(${\leq}1mm$) to total spacing(118.49 mm), (4) mean spacing($S_{mean}$), (5) difference value($S_{mean}-S_{median}$) between mean spacing and median spacing($S_{median}$), (6) density of spacing, (7) median spacing, (8) reduction ratio of spacing frequency to length frequency and (9) magnitude of exponent(${\lambda}$ and b) related to the distribution type of diagram. Especially the close dependence between the above spacing parameters and the parameters from the spacing-cumulative frequency diagrams was derived. The results of correlation analysis between the values of parameters for three rock cleavages and those for three planes are as follows. The values of (I) parameters(1, 2 and 3), (II) parameters(4, 5 and 6), (III) parameter(7), (IV) parameter(8) and (V) parameter(9) show the various orders of H(hardway, H1+H2) < G(grain, G1+G2) < R(rift, R1+R2), R < G < H, R < H < G, G < H < R and H < G < R, respectively. On the contrary, the values of the above four groups(I~IV) of parameters for three planes show reverse orders. This type of correlation analysis is useful for discriminating three quarrying planes. Six spacing-cumulative frequency diagrams were arranged in increasing order on the value of main parameter($S_{mean}-S_{median}$). These diagrams show an order of R2 < R1 < G2 < G1 < H2 < H1 from the related chart. In other words, the above six diagrams can be summarized in order of rift(R1+R2) < grain(G1+G2) < hardway(H1+H2). These results indicate a relative magnitude of rock cleavage related to microcrack spacing. Especially, the above main parameter could provide advanced information for prediction the order of arrangement among the diagrams.

Effective Geophysical Methods in Detecting Subsurface Caves: On the Case of Manjang Cave, Cheju Island (지하 동굴 탐지에 효율적인 지구물리탐사기법 연구: 제주도 만장굴을 대상으로)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Lee, Gyu-Ho;Rim, Hyoung-Rea;Oh, Seok-Hoon
    • Journal of the Korean earth science society
    • /
    • v.21 no.4
    • /
    • pp.408-422
    • /
    • 2000
  • Multiple geophysical methods were applied over the Manjang cave area in Cheju Island to compare and contrast the effectiveness of each method for exploration of underground cavities. The used methods are gravity, magnetic, electrical resistivity and GPR(Ground Pentrating Radar) survey, of which instruments are portable and operations are relatively economical. We have chosen seven survey lines and applied appropriate multiple surveys depending on the field conditions. In the case of magnetic method. two-dimensional grid-type surveys were carried out to cover the survey area. The geophysical survey results reveal the characteristic responses of each method relatively well. Among the applied methods, the electric resistivity methods appeared to be the most effective ones in detecting the Manjang Cave and surrounding miscellaneous cavities. Especially, on the inverted resistivity section obtained from the dipole-dipole array data, the two-dimensional distribution of high resistivity cavities are revealed well. The gravity and magnetic data are contaminated easily by various noises and do not show the definitive responses enough to locate and delineate the Manjang cave. But they provide useful information in verifying the dipole-dipole resistivity survey results. The grid-type 2-D magnetic survey data show the trend of cave development well, and it may be used as a reconnaissance regional survey for determining survey lines for further detailed explorations. The GPR data show very sensitive response to the various shallow volcanic structures such as thin spaces between lava flows and small cavities, so we cannot identify the response of the main cave. Although each geophysical method provides its own useful information, the integrated interpretation of multiple survey data is most effective for investigation of the underground caves.

  • PDF