• 제목/요약/키워드: Thin membrane

검색결과 525건 처리시간 0.025초

Pd-based metallic membranes for hydrogen separation and production

  • Tosti, Silvano;Basile, Angelo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.25-28
    • /
    • 2003
  • Low cost composite metallic membranes for the hydrogen separation and production have been prepared by using thin Pd-Ag foils reinforced by metallic (stainless steel and nickel) structures. Especially, “supported membranes” have been obtained by a diffusion welding procedure in which Pd-Ag thin foils have been joined with perforated metals (nickel) and expanded metals (stainless steel): in these membranes the thin palladium foil assures both the high hydrogen permeability and the perm-selectivity while the metallic support provides the mechanical strength. A second studied method of producing "laminated membranes" consists of coating non-noble metal sheets with very thin palladium layers by diffusion welding and cold-rolling. Palladium thin coatings over these metals reduce the activation energy of the hydrogen adsorption process and make them permeable to the hydrogen. In this case, the dense non-noble metal has been used as a support structure of the thin Pd-Ag layers coated over its surfaces: a proper thickness of the metal assures the mechanical strength, the absence of defects (cracks, micro-holes) and the complete hydrogen selectivity of the membrane. membrane.

  • PDF

Quantitative Analysis of Bayesian SPECT Reconstruction : Effects of Using Higher-Order Gibbs Priors

  • S. J. Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.133-142
    • /
    • 1998
  • Bayesian SPECT 영상재구성에 있어서 정교한 형태의 사전정보를 사용할 경우 bias 및 variance와 같은 통계적 차원에서의 정량적 성능을 향상시킬 수 있다. 특히, "thin plate" 와 같은 고차의 smoothing 사전정보는 "membrane"과 같은 일반적인 다른 사전 정보에 비해 bias를 개선시키는 것으로 알려져 있다. 그러나, 이와 같은 장점은 영상재구성 알고리즘에 내재하는 hyperparameters의 값을 최적으로 선택하였을 경우에만 적용된다. 본 연구에서는 thin plate와 membrane의 두가지 대표적인 사전정보를 포함하는 영상재구성 알고리즘의 정량적 성능에 대해 집중 고찰한다. 즉, 알고리즘에 내재하는 hyperparameters 가 통계적 차원에서 bias와 variance에 어떠한 영향을 미치는지 관찰한다. 실험에서 Monte Carlo noise trials를 사용하여 bias와 variance를 계산하며, 각 결과를 ML-EM 및 filtered backprojection으로부터 얻어진 bias 및 variance와 비교한다. 결론적으로 thin plate와 같은 고차의 사전정보는 hyperparameters의 선택에 민감하지 않으며, hyperparameters 값의 전 범위에 걸쳐 bias를 개선시킴을 보인다. 걸쳐 bias를 개선시킴을 보인다.

  • PDF

Membrane을 이용한 박막센서 특성 분석 (The Characteristic Analysis of Thin Film Sensor using The Membrane)

  • 이순우;김상훈;안진호
    • 마이크로전자및패키징학회지
    • /
    • 제9권3호
    • /
    • pp.37-41
    • /
    • 2002
  • 본 연구에서는 자기 공명 특성을 이용한 박막 센서의 멤브레인 및 박막 센서의 특성을 알아보았다. 멤브레인으로 유망한 물질로 $Si_xN_y$과 SiC가 있으며, 최적의 멤브레인 형성 조건을 알고자 박막의 잔류 응력 및 물성을 비교 분석하였다. 그 중에서 박막 센서에 적용 가능한 멤브레인으로 SiC보다 적절한 인장응력과 낮은 열팽창 계수를 가지는 $Si_xN_y$이 센서의 구조층으로 우수하였으며, $Si_xN_y$위에 박막 센서 물질을 증착 및 패턴닝(patterning)을 함으로써 센서의 자기 이력 곡선 및 자기 공진 주파수를 분석하였다. 센서에 인가되는 외부 자기장을 제거하면 자장에 의해 형성된 자화(magnetization)가 탄성 모드로 바뀌면서 에너지 방출에 의해 센서에서 전압이 발생하는데 이때 전압 발생 구간이 길어지면 기계적 진동이 야기되어 신호가 발생한다. 그리고 센서의 길이 및 폭이 증가할수록 자기공명 주파수가 감소하는 것을 볼 수 있다.

  • PDF

A novel approach to bind graphene oxide to polyamide for making high performance Reverse Osmosis membrane

  • Raval, Hiren D.;Das, Ravi Kiran
    • Membrane and Water Treatment
    • /
    • 제8권6호
    • /
    • pp.613-623
    • /
    • 2017
  • We report the novel thin film composite RO membrane modified by graphene oxide. The thin film composite RO membrane was exposed to 2000 mg/l sodium hypochloride; thereafter it was subjected to different graphene oxide concentration ranging from 50 mg/l to 1000 mg/l in water. The resultant membrane was crosslinked with 5000 mg/l N-hydroxysuccinimide. The performance of different membranes were analysed by solute rejection and water-flux measurement. It was found that 100 mg/l graphene oxide exposure followed by 5000 mg/l N-hydroxysuccinimide treatment resulted in the membrane with the highest solute rejection of 97.78% and water-flux of 4.64 Liter per sqm per hour per bar g. The membranes were characterized by contact angle for hydrophilicity, scanning electron micrographs for surface morphology, energy dispersive X-Ray for chemical composition of the surface, Atomic force microscope for surface roughness, ATR-FTIR for chemical structure identification. It was found that the graphene oxide modified membrane increases the salt rejection performance after exposure to high-fouling water containing albumin. Highly hydrophilic, antifouling surface formation with the nanomaterial led to the improved membrane performance. Moreover, the protocol of incorporating nanomaterial by this post-treatment is simple and can be applied to any RO membrane after it is manufactured.

SOI 멤브레인과 트랜치 구조상에 제작된 발열저항체형 마이크로 유량세선의 특성 (Characteristics of Hot-Film Type Micro-Flowsensors Fabricated on SOI Membrane and Trench Structures)

  • 정귀상;김미목;남태철
    • 한국전기전자재료학회논문지
    • /
    • 제14권8호
    • /
    • pp.658-662
    • /
    • 2001
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD(resistance thermometer device) and micro-heater on the SOI(Si-on-insulator) membrane and trench structures, in which MGO thin-film was used as medium layer in order to improve adhesion of Pt thin-film to SiO$_2$ layer. Output voltages increased due to increase of heat-loss from sensor to external. The output voltage was 250 nV at N$_2$ flow rate of 2000 sccm/min, heating power of 0.3 W. The response time($\tau$:63%) was about 42 msec when input flow was step-input. The results indicated that micro-flowsensors with the SOI membrane and trench structures have properties of a high-resolution and ow consume power.

  • PDF

Effect of NH3 plasma on thin-film composite membrane: Relationship of membrane and plasma properties

  • Kim, Eun-Sik;Deng, Baolin
    • Membrane and Water Treatment
    • /
    • 제4권2호
    • /
    • pp.109-126
    • /
    • 2013
  • Surface modification by low-pressure ammonia ($NH_3$) plasma on commercial thin-film composite (TFC) membranes was investigated in this study. Surface hydrophilicity, total surface free energy, ion exchange capacity (IEC) and zeta (${\zeta}$)-potentials were determined for the TFC membranes. Qualitative and quantitative analyses of the membrane surface chemistry were conducted by attenuated total reflectance Fourier transform infrared (ATR FT-IR) spectroscopy. Results showed that the $NH_3$ plasma treatment increased the surface hydrophilicity, in particular at a plasma treatment time longer than 5 min at 50 W of plasma power. Total surface free energy was influenced by the basic polar components introduced by the $NH_3$ plasma, and isoelectric point (IEP) was shifted to higher pH region after the modification. A ten (10) min $NH_3$ plasma treatment at 90 W was found to be adequate for the TFC membrane modification, resulting in a membrane with better characteristics than the TFC membranes without the modification for water treatment. The thin-film chemistry (i.e., fully-aromatic and semi-aromatic nature in the interfacial polymerization) influenced the initial stage of plasma modification.

역삼투 복합막 제조(II) 폴리에테르설폰막의 제조와 복합막 제조에 관한 연구 (A Study on the Preparation of Thin-Film Composite Membrane with Polyethersulfone Supporting Membrane)

  • 이동진;민병렬;이병철;송희열
    • 멤브레인
    • /
    • 제4권1호
    • /
    • pp.46-56
    • /
    • 1994
  • 새로운 복합막의 제조를 위하여 기존의 복합막에서 지지막으로 주로 사용되던 Polysulfone을 이보다 친수성이 뛰어난 Polyethersulfone막으로 대체하여 지지막을 직접 제조하고 이에 따른 복합막의 성능을 살펴 보았으며 이때 각 단계별로 제조막의 성능을 평가하여 각 단계별 최적 조건을 찾고자 하였다. 지지막은 Polythersulfone과 Polyvinylpyrrolidone의 조성에 따라 각각 실험하였으며, 활성층은 계면중합법에 의하여 m-Phenylene diamine과 Trimesoyl chloride를 반응시켜 제조하였다.

  • PDF

Fouling resistant membrane tailored by polyethylene glycol in oxidative environment for desalination

  • Kavaiya, Ashish R.;Raval, Hiren D.
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.381-385
    • /
    • 2019
  • Surface modification is very efficient and scalable approach to achieve improved membrane performance. We treated Reverse Osmosis Thin Film Composite (TFC RO) membrane with various concentrations of Polyethylene Glycol (PEG), a hydrophilic polymer after activation with sodium hypochlorite. This treatment resulted in an increment of the water flux by 43% and the salt rejection by 2.36% for the 3000 mg/l PEG-treated membrane. Further, these PEG-treated membranes were exposed to a mixture of 3000 mg/l PEG and 1000 mg/l sodium hypochlorite for 1 hour. Further modification of this membrane by PEG and sodium hypochlorite mixture increased the water permeance up to 133% when compared with the virgin TFC RO membrane. We characterized the treated membranes to understand the changes in wettability by contact angle analysis, changes in surface morphology and roughness by scanning electron microscope (SEM) and atomic force microscope (AFM) analysis.

나노여과를 위한 금속유기구조체 기반 박막 나노복합막의 최근 발전 (Recent Advances in Metal Organic Framework based Thin Film Nanocomposite Membrane for Nanofiltration)

  • 김에스더;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제31권1호
    • /
    • pp.35-51
    • /
    • 2021
  • 나노여과를위한 박막 나노복합체(TFN) 멤브레인 기술의 발전은 천연 자원에서 오염 물질을 제거하는 데 중요하다. 최근에는 기존의 박막 복합체(TFC) 및 나노복합체 멤브레인에서 불가피한 단점을 극복하기 위해 다양한 금속유기구조체(MOF) 수정이 테스트되었다. 일반적으로 MIL-101(Cr), UiO-66, ZIF-8 및 HKUST-1 [Cu3(BCT2)]은 용매 투과성 및 용질 제거 측면에서 막 성능을 현저하게 향상시키는 것으로 입증되었다. 이 리뷰에서는 이러한 MOF가 나노 여과에 미치는 영향에 대한 최근 연구가 논의될 것이다. 서로 다른 금속유기구조체의 동시 사용 및 고유한 금속유기구조체 레이어링 기술(예: 딥 코팅, 스프레이 사전 배치, Langmuir-Schaefer 필름 등)과 같은 다른 새로운 기능도 멤브레인 성능을 향상시켰다. 이러한 MOF 변형 TFN 멤브레인은 각각의 TFC 및 TFN 멤브레인에서 분리 성능을 향상시키는 것으로 자주 나타났을 뿐만 아니라 많은 보고서에서 비용 효율적이고 환경 친화적인 공정에 대한 잠재력을 설명한다.

박막형 NTC 열형 센서의 제작 및 특성 평가 (Fabrication and characteristic of thin-film NTC thermal sensors)

  • 유미나;이문호;유재용
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.65-70
    • /
    • 2006
  • Characteristics of thin-film NTC thermal sensors fabricated by micromachining technology were studied as a function of the thickness of membrane. The overall-structure of thermal sensor has a form of Au/Ti/NTC/$SiO_{X}$/(100)Si. NTC film of $Mn_{1.5}CoNi_{0.5}O_{4}$ with 0.5 mm in thickness was deposited on $SiO_{X}$ layer (1.2 mm) by PLD (pulsed laser deposition) and annealed at 873-1073 K in air for 1 hour. Au(200 nm)/Ti(100 nm) electrode was coated on NTC film by dc sputtering. By the results of microstructure, X-ray and NTC analysis, post-annealed NTC films at 973 K for 1 hour showed the best characteristics as NTC thermal sensing film. In order to reduce the thermal mass and thermal time constant of sensor, the sensing element was built-up on a thin membrane with the thickness of 20-65 mm. Sensors with thin sensing membrane showed the good detecting characteristics.