• Title/Summary/Keyword: Thin Coat

Search Result 61, Processing Time 0.029 seconds

High Power Characteristics of Amorphous $MnO_2$ Electrode by Variation of Electrode Thickness (비정질 $MnO_2$ 전극의 전극두께에 따른 고출력 특성 변화)

  • Seong W. K.;Kim E. S.;Lee H. Y.;Kim S. W.
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.235-240
    • /
    • 2000
  • Screen-printing and doctor blade method were investigated and proposed as an electrode coating process for high power capacitor. CV measured from the amorphous $MnO_2$ electrode prepared by screen-printing shows closer to ideal capacitor characteristics. Specific capacitances calculated from CVs with potential scan rate of 50mV/s were 5.8, 81.8, and 172.0 F/g for electrode thickness of $140{\mu}m,\;24{\mu}m,\; 3{\mu}m$, respectively. Assumed that utilization of active $MnO_2$ in electrode of screen-printing is $100\%$, those were $3.4\%$ in one of paste method and $47.6\%$ in one of doctor blade method. The screen-printing can be good technique to coat thin film on current collector for high power application.

A study on the Alteration of traditional costume of Korean Chinese (I) - Focused on the daily wear - (중국 조선족 전통복식의 변화연구 (I) - 일상복을 중심으로 -)

  • Lin, Huishun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.22 no.4
    • /
    • pp.63-78
    • /
    • 2020
  • Korean Chinese, immigrants to China, have developed their own traditional costume culture. This paper aims to analyze the traditional costume culture of the Korean Chinese and to provide data for posterity. The research methods are literature research, survey research, and analysis research. The results are as follows: According to the changes over generations, the top of women's Hanbok has changed in length as has the jeogori (jacket), the git (collar), and the gooreum (breast-tie). The width of the git, dong-jeong (thin white cloth-covered paper collar of Hanbok), the sleeve, and gooreum have also changed. The git and the barae (the curve part of the sleeve) have changed from straight patterns to curves. The skirt had changed in wrinkles arrangement, length, and silhouette. The men's Hanbok jeogori and sleeves were lengthened; the pants became wider and were lengthened, and the collar also became curved. The vest has not changed and the du-ru-ma-gi (coat) that once disappeared is being worn again; the bae-ja (vest) and magoja (over-jacket) are worn frequently in modern times. The garments mainly used natural fiber until the development of synthetic fibers, but the treand has been the use of luxurious natural fibers in modern times. The initial color pattern was achromatic, but that changed with the appearance of synthetic fibers, and nowadays it is mainly the garmetnt can display a variety of colors. In addition, hairstyles and shoes have been eveolved from traditional to modern styles.

Growth and Grain Characteristics of Thin-Shelled High-Yielding Lines of Job's-tears (Coix lacryma-jobi L.) (율무 박피(薄皮) 다수성(多收性) 선발(選拔) 계통(系統)의 생육(生育) 및 종실특성(種實特性))

  • Lee, Jung-Il;Park, Jang-Hwan;Kim, Sok-Dong;Ahn, Byeong-Ok;Lee, Seung-Tack
    • Korean Journal of Medicinal Crop Science
    • /
    • v.1 no.1
    • /
    • pp.24-27
    • /
    • 1993
  • This study was conducted to select thin-shelled and high-yielding lines in job's-tears. Two breeding lines of Suwon 3 and Suwon 6 were selected from the local collections. These two lines were tested and investigated on their characteristics under the field condition. The heading date of Suwon 3 and Suwon 6 was later one or two days, but the maturity date was one or two days earlier than that of check variety Kim-jejong, respectively. The number of grains per hill of Suwon 3, Suwon 6 was 50%, 49% greater and the milling rate was 3.8%, 5.6% higher than that of check variety, respectively. Althought 1000 grain weight of Suwon 3 and Suwon 6 was 20g lighter and the rate of ripeness was 6%, 12% lower, the raw grain yield was 22%, 20% higher than that of check variety, respectively. The thickness of seed coat of Suwon 3 and Suwon 6 was thiner and the hardness of seed coat was lower than that of check variety, therefore the milling time was decreased 12%, 7% compare to check variety, respectively. The crude protein contents of Suwon 3 and Suwon 6 was slightly higher and the amino acid composition of Suwon 6 was similar to Kimjejong, but Suwon 3 was lower than that of check variety.

  • PDF

Development and Transformation of Oocyte' Follicle Cell for Korean Four Sillurid Fishes of Liobagrus and Pseudobagrus (Pisces: Silluriformes) (한국산 동자개속 및 퉁가리속 4종 어류의 난모세포에서 여포세포의 발달과 변형)

  • Baek, Hyun-A;Park, Jong-Young;Kim, Chi-Hong;Kim, Jong-Hwa
    • Korean Journal of Ichthyology
    • /
    • v.19 no.2
    • /
    • pp.112-119
    • /
    • 2007
  • A histological study on development and transformation of the oocyte' follicle cell for Korean four sillurid fishes, Liobagrus obesus, L. mediadiposalis, Pseudobagrus koreanus, and P. brevicorpus was performed by light and electron microscopes. The follicular layer surrounding the oocyte consisted of an outer theca cell and an inner follicle cell (granulosa cell). The follicle cells of the oocyte were flatten cells at early oocyte but during vitellogenesis they were transformed it to a single layer of cuboidal cell, then to a single columnar cell layer, and finally to a layer covered with a substance secreted by themselves. Although the development and transformation of the follicle cells was similar to four species, the secreted materials, called an adhesive membrane, were divided into two types in its appearance and nature. Firstly, a jelly coat-like type was found in L. obesus and L. mediadiposalis, which they are presumed to be polysaccharides and mucoproteins in its nature and secondly, a granular type in P. koreanus and P. brevicopus, being mucoprotein. A zona radiata with about $0.6{\sim}3.1{\mu}m$ thin was present below the adhesive material secreted by the transformed-follicle cell's activity. The zona radiata was composed of two layers, a thin externa and a thick interna.

Property of Silica and Fine Structure of Cosmetic White Powders (화장품에 사용되는 백색분체의 미세구조와 실리카의 특성)

  • Jeon, Myung-Ok;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.87-93
    • /
    • 2012
  • In this study, fine structures of silica, titanium dioxide, talc and kaolin used in decorative cosmetics and the mixture extracted from BB cream cosmetics were observed by scanning electron microscopy. Kaolin had plate like shape structures of polygon with smooth surface and edge of kaolin had a relatively smooth appearance in comparison with talc. Also, thickness of each layer was estimated to about $0.1{\mu}M$ in the lump formed in stratum of several layers. Talc was observed by lumps shape phase of layering very thin flake. Boundary of thin flake was sharp or angular phase and thickness of flake was approximately 600 nm in diameter. When comparing the thickness of kaolin and talc, we was confirmed that kaolin was thicker than talc. Diameter of titanium dioxide was estimated to 0.2~0.3 ${\mu}M$ and surface of particle was a soft cubic form. Silica was confirmed that variety of size from 200 nm to $15{\mu}M$ of globular shape was measured. From the observation of inorganic pigments, silica was homogeneous dispersed in the BB cream cosmetics and among each other was filled with relatively small size like talc, kaolin, titanium dioxide and iron oxide. In conclusion, we suggest that silica at decorative cosmetics were formed in cosmetic coat at the skin as the minimum thickness.

Synthesis Characterization and Biodistribution of $^{99m}Tc$-Ethyl-3-Isocyanobutyrate as a New Myocardial Perfusion Agent (새로운 심관관류 영상 화합물로서 $^{99m}Tc$-Ethyl-3-Isocyano-butyrate의 합성, 표지 및 체내동태에 대한 연구)

  • Lee, Myung-Chul;Cho, Jung-Hyuck;Lee, Dong-Soo;Lim, Sang-Moo;Oh, Seung-Joon;Chung, Soo-Wook;Lee, Kyung-Han;Jeong, Jae-Min;Chung, June-Key;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.223-232
    • /
    • 1993
  • Technetium labeled isonitrile analogues are widely used as myocardial perfusion imaging agents. We synthesized and characterized a new isonitrile compound, ethyl 3-isocyanobutyrate(EIB). Proton and $^{13}C$ NMR spectroscopy and thin layer chromatography with a $C_{18}$ coat was performed. EIB was easily labeled with $^{99m}TcO_4^-$- with sodium dithionite. The labeling efficiency measured by RP-HPLC was over 95%. The labeled product was stable with dilution in normal saline and with prolonged incubation at room temperature. There was no formation of secondary products or free $^{99m}TcO_4^-$. In vivo kinetics study of $^{99m}Tc$ (I) labeled EIB in rabbits showed adequate myocardial uptake, good contrast against lung background, and relatively rapid liver clearance. The heart to lung ratio was over 2.5 and the heart to liver ratio was approximately from 0.4 to 5 at 60 minutes post injection. Hepatic clearance of $^{99m}Tc-MIBI$ was faster ($t_{1/2}$=6 minutes) than that of $^{99m}Tc-MIBI$. In vivo kinetics observed in dog was similar to that in rabbit but there was faster gallbladder filling, and thus lower liver background. SPECT imaging of the canine myocardium showed favorable imaging characteristics. However, biodistribution in mice demonstrated a myocardial % injected dose/organ of less than 0.1%. This was thought to be due to interspecies difference in plasma esterase activity. In human plasma, $^{99m}Tc$ ( I ) labeled EIB was stable for at least 2 hours, without production of secondary products by HPLC. We conclude that ethyl 3-isocyanobutyrate may be a potential new myocardial perfusion imaging agent and deserves further investigation as to its usefulness for clinical use.

  • PDF

Fabrication of Electrolyte for Direct Carbon Fuel Cell and Evaluation of Properties of Direct Carbon Fuel Cell (직접탄소 연료전지용 전해질 제조 및 직접탄소 연료전지 특성 평가)

  • Pi, Seuk-Hoon;Cho, Min-Je;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.786-789
    • /
    • 2011
  • In order to estimate the possibility of applying electrolytes generally used in solid oxide fuel cells(SOFCs) to direct carbon fuel cells(DCFCs), properties of YSZ(yttria stabilized zirconia) electrolyte were evaluated. In this study, vacuum slurry coating method was adapted to coat thin layer on anode support substrate. After sintering the electrolyte at $1400^{\circ}C$ for 5hrs, microstructure was analyzed by using SEM image. Also, gas permeability and ionic conductivity were measured to find out the potential possibility of electrolyte for DCFCs. The YSZ electrolyte represented dense coating layer and low gas permeability value. The ionic conductivity of YSZ electrolyte was high over $800^{\circ}C$. After measurement of the electrolyte properties, direct carbon fuel cell was fabricated and its performance was measured at $800^{\circ}C$.

Magnetic Properties and Application of Caltalysts in Biginelli Reaction for the Ni and Ni@C Synthesized by Levitational Gas Condensation (LGC) (부양증발응축법으로 제조된 Ni과 Ni@C의 자성특성 및 Biginelli 합성 촉매 적용연구)

  • Uhm, Young Rang
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.3
    • /
    • pp.87-91
    • /
    • 2017
  • Carbon-encapsulated Ni and metal Ni nanoparticles were synthesized by levitational gas condensation (LGC). Methane ($CH_4$) gas was used to coat the surface of the Ni nanoparticles. The Ni particles had a core diameter of 10 nm, and were covered by 2~3 nm thin carbon layers with multi-shells structure.The low magnetization comparing with the Ni nanoparticles without carbon-shell results in the coexistence of nonmagnetic carbon and a large surface spin percentage with disordered magnetization orientation for the nanoparticles. Biginelli reactions in the presence of L-proline and Ni and carbon encapsulated Ni nanoparticles were carried out to change the ratio between stereoisomers. The obtained S-enantiomers for 3,4-dihydropyrimidine (DHPM) using catalysts of Ni, and Ni@C was an excess of about ${\Delta}{\sim}7.4%$ and ${\Delta}{\sim}19.6%$, respectively. The nanopowders were fully recovered using magnet to reuse as a catalyst. The Ni@C was shown at same yield to formation of 3,4-DHPM, though it was recycled for catalyst in the reaction.

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF