• Title/Summary/Keyword: Thickness change

Search Result 2,328, Processing Time 0.023 seconds

Consideration of thickness change during progressive drawing process of automotive coupler parts(AL5052-H32) (자동차 커플러 부품(Al5052-H32)의 프로그래시브 드로잉 공정 시 두께 변화 고찰)

  • Park, Sang-Byung;Yun, Jae-Woong
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2020
  • Progressive drawing processing is one of the manufacturing processes used to mass-produce a variety of products on the industrial site. In this study, the goal is to achieve a uniform product thickness of at least 1.3mm by reducing the wall thickness of the coupler parts used in automotive air conditioning systems to within 15% using A5052-H32 materials. The progressive die was designed using Blank's law of volume invariance. Due to the characteristics of the drawing process, the material thickness in the punch R part decreases and the thickness in the die R part increases. When designing the progressive die of the coupler part, an ironing method, a push back method, and a stand-alone die pad method were applied to each process to design a mold in consideration of the drawing rate and to artificially adjust the thickness change. The suitability of the method used in die design was investigated by measuring the thickness change of forming parts for each process. In the final part, it was confirmed that the thickness measurement values of the five regions of a radial line were implemented as 1.34-1.36 mm.

Detection of Corrosion and Wall Thinning in Carbon Steel Pipe Covered With Insulation Using Pulsed Eddy Current

  • Park, Duck-Gun;Kishore, M.B.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.57-60
    • /
    • 2016
  • Non Destructive Testing (NDT) methods that are capable of detecting the wall thinning and defects through insulation and cladding sheets are necessary. In this study we developed a Pulsed Eddy Current (PEC) system to detect wall thinning of ferro magnetic steel pipes covered with 95 mm thick fiber glass thermal insulator and shielded with aluminum plate of thickness 0.4 mm. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and a search coil sensor were used as a detecting element. In both the cases, the experimental data indicates a considerable change in the detected pulse corresponding to the change in sample thickness. The thickness of the tube was made to change such as 2.5 mm, 5 mm and 8 mm from the inner surface to simulate wall thinning. Fast Fourier Transform (FFT) was calculated using window approach and the results were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra.

A study on the change of thickness according to material change of water purifier cold and hot water tank cylindrical drawing products (정수기 냉온수 탱크 원통형 드로잉 제품의 재질 변화에 따른 두께 변화에 관한 연구)

  • Jang, Eun-Jeong;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.13-18
    • /
    • 2021
  • In plate forming technology, cylindrical drawing process is widely used in industry due to technological development. In this study, we used stainless steel 3042B and stainless steel 304J1, which are the most commonly used materials in the production of cold and hot water tanks for water purifiers, among cylindrical drawing products. Under the same conditions, the thickness of the sidewall of the product formed by drawn experiment was studied. As a result of the experiment, the bottom thickness of stainless steel 304J1 was considered to be thick. It is judged that the defect rate can be reduced by changing the breaking phenomenon of the floor surface of the cold and hot water bottles to the material of stainless steel 304j1. Stainless steel 304 2B material shows a sharp change in thickness from punch corner R to sidewall position, while stainless steel 304J1 material showed a uniform change from punch corner R to sidewall position. Stainless steel 304J1 material is considered to improve the clamping of the product in the process of extracting the product after hand drawing. The appearance of stainless steel 3042B products is considered to produce more wrinkles in the flange, which exerts greater tensile force on the sidewall during molding, resulting in uneven sidewall thickness.

A study on magnetic layer thickness effects on magnetic properties of CoCrPt/Ti perpendicular media.

  • M. S. Hwang;Lee, T. D.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.369-376
    • /
    • 2000
  • Change of magnetic properties in CoCrPt/Ti perpendicular media with varying CoCrPt films thickness has been studied. As CoCrPt films thickness increase, the Ms(magnetization saturation) drastically increases at thinner thickness and gradually increases with further increase in thickness from 25nm. This Ms behaviour is associated with primarily the formation of "amorphous-like" reacted layer by intermixing of CoCrPt and Ti at CoCrPt/Ti interface and secondarily change of Cr segregation mode with varying the CoCrPt films thickness. Magnetic domain structure distinctively changes with increasing CoCrPt magnetic layer(ML) thickness. Also the strength of exchange coupling measured from the slope in demagnetizing region in M-H loop changes with ML thickness. Details of the above magnetic properties will be discussed. The expansion of lattice parameters a and c at thinner thickness suggests that Cr segregation mode may be connected with the residual stress of the films. Finally, negative nucleation field(Hn) behaviour with the exchange slope will be reported.

  • PDF

The effect of repeated firings on the color change and surface roughness of dental ceramics

  • Gonuldas, Fehmi;Yilmaz, Kerem;Ozturk, Caner
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.309-316
    • /
    • 2014
  • PURPOSE. The color of the ceramic restorations is affected by various factors such as brand, thickness of the layered the ceramic, condensation techniques, smoothness of surface, number of firings, firing temperature and thickness of dentin. The aim of this study was to evaluate the color change and surface roughness in dental porcelain with different thicknesses during repeated firings. MATERIALS AND METHODS. Disc-shaped (N=21) metal-ceramic samples (IPS Classic; Ivoclar Vivadent; Shaar, Liechtenstein) with different thickness were exposed to repeated firings. Color measurement of the samples was made using a colorimeter and profilometer was used to determine surface roughness. ANOVA and Tukey tests with repeated measurements were used for statistical analysis. RESULTS. The total thickness of the ceramics which is less than 2 mm significantly have detrimental effect on the surface properties and color of porcelains during firings (P<.05). CONCLUSION. Repeated firings have effects on the color change and surface roughness of the dental ceramics and should be avoided.

Influence of soft tissue and bone thickness on the dimensional change of peri-implant soft tissues;A clinical follow-up study (연조직 및 골 두께가 임플란트 주위 연조직 형태에 끼치는 영향에 관한 임상추적연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.187-197
    • /
    • 2005
  • The aim of this study was to investigate the influence of peri-implant soft tissue and bone thickness on the early dimensional change of peri-implant soft tissue. Seventy-seven non-submerged implants of 39 patients which had been loaded more than 6 months were selected for the study. Following clinical parameters were measured; bucco-lingual bone width of the alveolar bone for implant placement before implant surgery; distance between implant shoulder and the first bone/implant contact at the surgery; presence of plaque, probing depth, bleeding on probing, width of keratinized mucosa, mucosa thickness, distance between implant shoulder and peri-implant mucosa, crown margin location at follow-up examination. The results showed that distance between implant shoulder and peri-implant mucosa (DIM) was correlated with probing depth and width of keratinized mucosa (p < 0.05). In addition, mucosa thickness was also correlated with probing depth (p<0.05). However, the bone width of alveolar bone and soft tissue thickness were not found to be correlated with DIM. It is important to understand the meaning of peri-implant tissue dimension in relation to dimensional changes of peri-implant soft tissue which designates appearance of implant-supported restorations. Future study is needed to elucidate the significance of the buccal bone thickness and soft tissue thickness with respect to the change of peri-implant soft tissue margin with the use of an instrument capable of measuring buccal bone thickness directly.

Comparison of Changes in the Thickness of the Abdominal Muscles in Different Standing Positions in Subjects With and Without Chronic Low Back Pain (만성 요통 유무와 자세에 따른 복부근 두께변화 비교)

  • Won, Jong-Im
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.415-424
    • /
    • 2020
  • Purpose: This study aimed to compare changes in abdominal muscle thickness in different standing postures with a handheld load between subjects with and without chronic low back pain (CLBP). Methods: Twenty subjects with CLBP and 20 controls participated in this study. Ultrasound imaging was used to assess the changes in the thickness of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles. Muscle thickness in three different standing postures (standing at rest, standing with loads, standing with lifting loads) was compared with the muscle thickness at rest in the supine position and was expressed as a percentage of change in the thickness of the muscle. Results: While standing with loads, the change in IO muscle thickness in the CLBP patients increased more significantly than in the pain-free controls (p < 0.05). The standing with lifting loads posture showed a significant increase in the change in thickness of the TrA compared with the standing with loads posture (p < 0.05). In addition, the standing with lifting loads posture showed a significant decrease in the change in the thickness of the EO when compared with the standing with loads posture (p < 0.05). Conclusion: The automatic activity of the IO muscle in subjects with CLBP increased more than that of the pain-free controls in the standing with loads posture. These findings suggest that IO muscle function may be altered in those with CLBP while standing with loads. Additionally, TrA the activation level was found to be associated with increased postural demand caused by an elevated center of mass.

THE THICKNESS OF SOFT-TISSUE BASED ON BODY MASS INDEX AND POSTOPERATIVE CHANGE IN PROGNATHIC PATIENTS (골격성 III급 부정교합자의 체질량지수에 따른 술후 연조직 변화)

  • Kim, Eun-Cheol;Lee, Sang-Chull
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.288-297
    • /
    • 1999
  • This study has been carried out in order to measure the thickness of soft-tissue on lateral cephalographs based on body mass index(BMI) and the change in soft-tissue thickness after surgical correction of mandibular protrusion. The control material in cephalometric study comprised students at The Dental College, 38 persons, aged 21~24 years and the patient material comprised 20 women and 12men, aged 19~28 years with mandibular protrusion.The thickness of the soft-tissue based on BMI in control and study groups, the comparison between them, immediate postoperative change in the thickness, 6 months after surgery, ratio of soft-tissue response and correlation was established through various statistical methods. The result were as follows : 1. The groups based on BMI showed significant differences each other as regards the linear measurements. The thickest soft-tissue was measured 13.6mm, 15.47mm, 16.76mm at Ss, the thinnest at G' 6.0mm, 6.7mm, 7.26mm respectively. 2. The differences between control and experimental groups based on BMI showed to be significant. There were no differences at G'. The soft-tissue in prognathic patients was thicker at Ss, Ls and thinner at Li, Ls, Pg', Gn', Me'. Differential gap was greater in overweight groups. 3. The immediate soft-tissue change after surgery showed the increase at Li, Ls, Pg', Gn', Me' except G', Ls in all groups. 4. The postoperative soft-tissue change 6 months after surgery was similar with immediate change. The soft-tissue shows the increase in the thickness at Li, Pg', Gn', Me' and the greatest difference occurred at Li, 1.1mm, 0.98mm, 1.2mm respectively. 5. The patients with lower BMI index showed higher soft-tissue response to bony movement at Pg'. The immediate response ratio was 91%, 87%, 81% in A,B,C groups respectively, the response 6 months after surgery showed 96%, 91%, 84%.

  • PDF

Effects of Bridge Exercise Combined with Vibration on Abdominal Muscle Thickness (진동을 병행한 교각운동이 복부 근육 두께에 미치는 영향)

  • Jae Cheol Park;Jin Gyu Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2023
  • Background: The purpose of this study was to confirm the effect of bridge exercise combined with vibration on abdominal muscle thickness. Design: Randomized controlled trial. Methods: As study subjects, 24 adults in their 20s were classified into 12 vibration bridge exercise groups and 12 bridge exercise groups. The time was divided into before the experiment, 3 weeks after the experiment, and 6 weeks after the experiment. Two-way repeated ANOVA was used to examine changes in the muscle thickness of the external oblique, internal oblique, and transverse abdominal muscles of the trunk muscles, and the significance level was set at 0.05. If there was an interaction between time and group, post-hoc analysis was performed, and the significance level was set at 0.01. Results: There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). Conclusion: As a result of this study, bridge exercise combined with vibration had a positive effect on the muscle thickness of the external oblique, internal oblique, and transversus abdominis muscles. It suggests the possibility of using the basic data of vibration exercise and the lumbar stabilization exercise in clinical practice.

A study on the thickness change according to the necking ratio of aluminum tube(A3003, A6061) (알루미늄 튜브(A3003, A6061)의 축관률에 따른 두께 변화에 관한 연구)

  • Oh, Jong-Seong;Min, Kyung-Ho;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.37-42
    • /
    • 2021
  • The tube necking process increases the thickness of the material, and some of the tube necking products require cutting on the inside of the formed product as a post-process. In order to prevent over-cutting or un-cutting due to increased thickness during cutting, it is necessary to know in advance the increase in thickness after forming. Therefore, in this study, the thickness change according to the tube necking was observed. Aluminum 3003-F and 6061-O were used for the materials used in the experiment, and necking was carried out up to 50% of the outer diameter of the tube through five processes. The two materials were formed under the same conditions, and the thickness of three points was observed in each process. In addition, the thickness increase of the two materials was compared, and the trend of thickness increase according to the cumulative necking ratio was observed. As a result of the experiment, both materials had the smallest thickness at the end of the formed product. In addition, as a result of comparing the thickness measurement values of the two materials, the maximum difference was 0.1mm, indicating that there was no difference in thickness between the two materials.