• Title/Summary/Keyword: Thickness Uniformity

Search Result 364, Processing Time 0.031 seconds

Fabrications of Pd/poly 3C-SiC schottky diodes for hydrogen gas sensor at high temperatures (고온 가스센서용 Pd-다결정 3C-SiC 쇼트키 다이오드 제작)

  • Ahn, Jeong-Hak;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.78-79
    • /
    • 2008
  • In this paper, poly 3C-SiC thin films were grown on $SiO_2$/Si by atmospheric pressure chemical vapor deposition (APCVD) using HMDS, $H_2$, and Ar gas at $1100^{\circ}C$ for 30 min, respectively. And then, palladium films were deposited on poly 3C-SiC by RF magnetron sputter. Thickness, uniformity, and quality of these samples were performed by SEM. Crystallinity and preferred orientationsof palladium were analyzed by XRD. And Pd/poly 3C-SiC schottky diodes were fabricated and characterized by current-voltage measurements. Its electric current density Js and barrier height voltage were measured as $2\times10^{-3}$ A/$cm^2$, 0.58 eV, respectively. And these devices operated about $350^{\circ}C$. From results, Pd/poly 3C-SiC devices are promising for high temperature hydrogen sensor and applications.

  • PDF

Properties of PZT Ultrasonic Transducer Array Fabricated by Micro-Pressing and Dicing method (Micro-Pressing 방법과 Dicing 방법에 의해 제조된 PZT Ultrasonic Transducer Array의 특성)

  • Park, Joon-Shik;Hong, Sung-Jei;Cho, Jin-Woo;Park, Soon-Sup;Han, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2248-2250
    • /
    • 2000
  • We investigated properties of PZT composite for medical ultrasonic transducer array (briefly UTA) for medicine applications fabricated by micro pressing and dicing method. Dicing method was the fabrication process of conventional ultrasonic transducer array by dicing sintered PZT sheet. Micro pressing method was the proposed process using pressing PZT green sheet by PMMA micro mold from LIGA process. Microstructures, electrical and electro -mechanical properties of fabricated UTAs of two cases were analyzed. Thickness mode electro-mechanical coupling coefficient of two cases have same values of 51%. Sintered PZT Microstructures of them showed dense and uniform. Micro pressing method was very mass productive process because of using batch type LIGA process. From results, we found micro pressing method was more competitive than dicing method for UTA fabrication. For further study, uniformity of microstructures and electro-mechanical properties of large scale, and fabrication processes of Ni plating and PMMA molding should be improved and investigated.

  • PDF

Characterization of Direct Laser Metal Forming Technology for the Restoration of Mold Surface (레이저 직접금속성형기술을 이용한 금형재 표면보수 특성 연구)

  • Son, Young-Myung;Jang, Jeong-Hwan;Joo, Byeong-Don;Yim, Hong-Sup;Moon, Young-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.7
    • /
    • pp.681-686
    • /
    • 2009
  • Direct laser metal forming technology was applied to restore the damaged mold surface. In order to estimate melting characteristics of the $20{\mu}m$ Fe-Cr-Ni powder, single layer experiments were performed at various levels of heat input. The process window of the $20{\mu}m$ Fe-Cr-Ni powder provided feasible process parameters for the smooth regular surface. The cross hatching scanning strategy on the multiple layer experiment was performed to reduce the thickness non-uniformity of edge portions compared with the one direction scanning. To estimate the coherence between the melted powder and the basematal, the tendency of hardness distribution has been observed. The hardness of the melted and the remelted zone was distributed from 400HV to 600HV. It is over 2 times compared of the hardness of the basemetal. Experimental results show that the mold restoring process using direct laser metal forming can be successfully applied in the mold repair industry.

Development of rotary-magnet type magnetron source for large area sputtering on flexible substrate (대면적 플랙시블 기판용 회전자석형 마그네트론 소스 개발)

  • Cho, Chan Seob;Yun, Sung Ho;Kim, Bong Hwan;Kim, Kwang Tae;Jung, Young Chul;Lee, Jong Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • In this study, a high performance rotary magnet type magnetron source for roll-to-roll sputter system has been developed. We analyzed the density of magnetic field as a function of size variation of the magnet which are in the center and edge of the target. The target efficiency showed the best result when the width of center magnet, the width of edge magnet, the angle of edge magnet, and the rotation angle of Yoke are 20mm, 10mm, $56^{\circ}$, and $16^{\circ}$, respectively. On the basis of the results of magnet array, Roll-to Roll magnetron source was fabricated and tested. The uniformity of the film thickness and that of the sheet resistance was ${\pm}1.62%$ and ${\pm}4.13%$, and the resistivity was $2.79{\times}10^{-3}W{\cdot}cm$.

The Fabrication of (Ga, Al) As/GaAs Modified Multi-Quantum Well Laser Diode by MOCVD (MOCVD법에 의한 (Ga, Al) As/GaAs 변형된 영지우물 레이저 다이오드의 제작)

  • Kim, Chung-Jin;Kang, Myung-Ku;Kim, Yong;Eom, Kyung-Sook;Min, Suk-Ki;Oh, Hwan-Sool
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.9
    • /
    • pp.36-45
    • /
    • 1992
  • The Modified Multi-Quantum Well(MMQWAl) structures have been grown by Mental-Organic chemical Vapor Deposition(MOCVD) method and stripe type MMQW laser diodes have been investigated. In the case of GaAs/AlGaAs superlattice and quantum well growth by MOCVD, the periodicity, interface abruptess, Al compositional uniformity and layer thickness have been confirmed though the shallow angle lapping technique, double crystal x-ray diffractometry (DCXD) and photoluminescence (PL) measurement. stripe-type MMQW laser diodes have been fabricated using the process technology of photolithography, chemical etching, ohmic contact, back side removing and cleaving. As the result of the electrical and opticalmeasurement of these laser diodes, we have achieved the series resistance of $1[\Omega}~2{\Omega}$ by current-voltage measurements, the threshold current of 200-300mA by currnt-light measurements and the lasing wavelength of 8000-8400$\AA$ by lasing spectrum measurements.

  • PDF

Depositions of Pd thin films on poly-crystalline 3C-SiC buffer layers for microsensors (다결정 3C-SiC 완충층위에 마이크로 센서용 Pd 박막 증착)

  • Ahn, Jeong-Hak;Chung, Jae-Min;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.175-176
    • /
    • 2007
  • This paper describes on the characteristics of Pd thin films deposited on poly-crystalline 3C-SiC buffer layers for microsensors, in which the poly 3C-SiC was grown on Si, $SiO_2$, and AlN substrates, respectively, by APCVD using HMDS, $H_2$, and Ar gas at $1100^{\circ}C$ for 30 min. In this work, a Pd thin film was deposited on the poly 3C-SiC film by RF magnetron sputter. The thickness, uniformity, and quality of these samples were evaluated by SEM. Crystallinity and orientation of the Pd film were analyzed by XRD. Finally, Pd/poly 3C-SiC schottky diodes were fabricated and characterized by current-voltage measurements. From these results, Pd/poly 3C-SiC devices are promising for high temperature hydrogen sensors and other microsensors.

  • PDF

A Study on Improved Pore Uniformity of Nano Template Using the Rapid Thermal Processor (급속열처리를 통한 알루미나 나노템플릿의 기공 균일도 개선에 관한 연구)

  • Kim, Dong-Hee;Kim, Jin-Kwang;Kwon, O-Dae;Yang, Kea-Joon;Lee, Jae-Hyeong;Lim, Dong-Gun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.637-638
    • /
    • 2005
  • AAO templates were fabricated using a two-step anodization process with pretreatment such as electro polishing and annealing. To reduce process time and get well-aligned pore array, rapid thermal processor by an halogen lamp was employed in vacuum state at $500^{\circ}C$ for various time. The pore array of AAO template annealed at $500^{\circ}C$ for 2 h is comparable to a template annealed in conventional furnace at $500^{\circ}C$ for 30 h. The well-fabricated AAO template has the mean pore diameter of 70 nm, the barrierlayer thickness of 25 nm, and the pore depth of $9{\mu}m$. And the pore density can be as high as $2.0\times10^{10}cm^{-2}$.

  • PDF

Permanent Support for Tunnels using NMT

  • Barton, Nick
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 1995.03a
    • /
    • pp.1-26
    • /
    • 1995
  • Key aspects of the Norwegian Method of Tunnelling (NMT) are reviewed. These include a predictive method of support design using the six-parameter Q-system of rock mass characterisation. The rock mass rating or Q-value is updated during tunnel driving. The designed tunnel support generally consists of wet process, steel fibre reinforced shotcrete combined with fully grouted, untensioned rock bolts, Even in poor rock conditions S(fr) + B usually acts as the final rock reinforcement and tunnel lining. Since it is a drained lining, it is very economic compared to cast concrete with membranes. Light, free-standing steel liners are used to prevent water affecting the runnel environment. Rock mass conditions, and hence lining design and cost estimation can be assessed by careful use of seismic surveys. Relationships between the P-wave velocity, the rock mass deformation modulus and the Q-value have recently been established, where tunnel depth, rock porosity and the uniaxial compression strength of the rock are important variables. The rock mass modulus estimate, and simple index testing of the joints, provide the key input which joints are discretely represented (either in two dimensions with the UDEC code or in three dimensions with the 3DEC code) is generally favoured compared to continuum analysis. The latter may give a misleading impression of uniformity and deformations tend to be understimated. Q-system NMT designs of S(fr) + B (fibre reinforced shotcrete and bolting) are numerically checked and adjustments made to bolt capacities and shotcrete thickness if overloading is evident around the modelled profile.

  • PDF

Flow Behavior of Thin Polymer Film in Spinning Coating Process of Blu-ray Disc Cover layer (블루레이 디스크의 커버레이어 스핀코팅 시 폴리머 거동에 관한 연구)

  • Ban J. H.;Shin H. G.;Kim B. H.;Kim H. Y.;Lee H. G.;Son S. G.;Shin J. K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.113-116
    • /
    • 2005
  • In this paper, a computational and experimental analysis about the flow behavior of thin polymer film in the spin coating process for stable cover layer coating of a blu-ray disc is described. The blu-ray disc, a next-generation optical disc format over 25GB, consists of a 1.1mm thick substrate and a 0.1mm tick cover layer. Generally, cover layer on the blu-ray disc is made by the polymer spin coating process. However, it is hard to secure sufficient coating uniformity around the rim on the cover layer. In order to get the uniform thickness deviation and to minimize the bead around the rim, the edge of the disc substrate can be modified into various shapes around the rim on the disc and analyzed with various parameters, such as surface tension, viscosity, and rotation speed, etc. The optimal shape of the rim was tried to get by 3 dimensional computer simulation of the polymer expulsion process.

  • PDF

Manufacturing and characterization of ECR-PECVD system (ECR-PECVD 장치의 제작과 특성)

  • 손영호;정우철;정재인;박노길;황도원;김인수;배인호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • An ECR-PECVD system with the characteristics of high ionization rat다 ability of plasma processing in a wide pressure range and deposition at low temperature was manufactured and characterized for the deposition of thin films. The system consists of a vacuum chamber, sample stage, vacuum gauge, vacuum pump, gas injection part, vacuum sealing valve, ECR source and a control part. The control of system is carried out by the microprocessor and the ROM program. We have investigated the vacuum characteristics of ECR-PECVD system, and also have diagnosed the characteristics of ECR microwave plasma by using the Langmuir probe. From the data of system and plasma characterization, we could confirmed the stability of pressure in the vacuum chamber according to the variation of gas flow rate and the effect of ion bombardment by the negative DC self bias voltage. The plasma density was increased with the increase of gas flow rate and ECR power. On the other hand, it was decreased with the increase of horizontal radius and distance between ECR source and probe. The calculated plasma densities were in the range of 49.7\times10^{11}\sim3.7\times10^{12}\textrm{cm}^{-3}$. It is also expected that we can estimate the thickness uniformity of film fabricated by the ECR-PECVD system from the distribution of the plasma density.

  • PDF