• Title/Summary/Keyword: Thickness Measurements

Search Result 1,154, Processing Time 0.025 seconds

Effect of Lateral Diffusion on Hydrogen Permeation Measurement in Thick Steel Specimens

  • Traidia, A.;El-Sherik, A.M.;Attar, H.;Enezi, A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.201-208
    • /
    • 2017
  • A finite element analysis is proposed to study the effect of specimen dimensions on lateral diffusion of hydrogen during hydrogen permeation flux measurements. The error of measurement on thick specimens because of 1D diffusion approximation may be as much as 70%. A critical condition for accurate measurements is to designate the area of hydrogen monitoring/exit surface smaller than the area of hydrogen charging/entry surface. For thin to medium thickness specimens (ratio of thickness to specimen radius of 5:10 and below), the charging surface should be maximized and the monitoring surface should be minimized. In case of relatively thick specimens (ratio of thickness to specimen radius above of 5:10), use of a hydrogen-diffusion barrier on the specimen boundaries is recommended. It would completely eliminate lateral losses of hydrogen, but cannot eliminate the deviation towards 2D diffusion near the side edges. In such a case, the charging surface should be maximized and the monitoring surface should be as closer in dimension as the charging surface. A regression analysis was carried out and an analytical relationship between the maximum measurement error and the specimen dimensions is proposed.

Improvement of an Ultrasonic Transducer for Measuring Both Flow Velocity and Pipe Thickness (유속 및 파이프 두께 측정 겸용 초음파 트랜스듀서 개선)

  • Kim, Ju Wan;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.148-156
    • /
    • 2016
  • The paper deals with improvement of a piezoelectric ultrasonic transducer for measuring both pipe thickness and flow velocity. The transducer structure is based on the conventional transducers for measuring flow velocity by obliquely transmitting ultrasonic waves to the flow direction. The transducer invented earlier for measuring flow velocity and pipe thickness had an advantage of including only one piezoelectric disc, but for the thickness measurement the ultrasonic wave had to be reflected twice in a wedge material to be transmitted vertically to a pipe, and thus the wave signal was too weak. The transducer has been improved to transmit waves for thickness measurement vertically to a pipe without any prior reflection by electrically connecting two piezoelectric discs, one for flow velocity and the other for pipe thickness measurement. By comparing the measured results of specimen thickness with the improved transducer and conventional transducers, the accuracies of the improved one have been evaluated in the pipe thickness measurements.

A Study on the Analysis of Korean Adults' Bead-type and the Distribution of Size for Improving the Fitness of Swimming Headgear (수영모 맞음새 개선을 위한 한국인의 두형분석과 치수분포에 관한 연구)

  • Kim, In-Sook;Kwon, Myoung-Sook;Yang, Min-Jae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1079-1091
    • /
    • 2005
  • The purpose of this study was to point out the unification of the size of swimming headgear by measuring detailed measurement of head ferm and systematizes the head form. A total of 300 male and female Korean adults aged from 18 years old to 35 years old were measured through the direct measurement method. This study attempted to identify the head form of male and female adults using measurement data and the head form was classified through factor analysis and cluster analysis. (1) Based on the fact that this study especially focuses on the size of swimming headgear, factor analysis was performed far both direct measurements with hair and without hair. For the measurements with hair, seven factors were extracted. They were head thickness factor, head width factor, width of side head factor, height of back head factor, length of front head factor, circumference of front head factor, thickness of front head factor and head height factor. They explained the $70.95\%$ of the measurements. (2) The cluster analysis was executed to classify the somatotype of the korean head form on the basis of similarity. According to the cluster analysis result, the measurements with hair categorized types, 'Woman's long-hair type', 'Small type', 'Long and flat type', 'Large type'. (3) Head circumference B and Left tragion - Vertex - Right tragion circumference which are generally length and width in choosing swimming headgear size were selected as measurement items far size of swimming headgear. Direct measurements and sizes of four swimming headgear with different materials taking into account their elongation rate were also compared.

Effects of Neuromuscular Electrical Stimulation Training on Abdominal Fat, Trunk Muscle Thickness and Activity in Middle-Aged Women with Abdominal Obesity (전기근육자극 훈련이 복부비만 중년 여성의 복부지방, 체간 근 두께와 활성도에 미치는 영향)

  • Yoo, Seung-Ah;Yoo, Kee-Ung;Lim, Chang-Ha;Kim, Chang-Yong;Kim, Hyeong-Dong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.125-135
    • /
    • 2019
  • PURPOSE: This study examined the effects of low frequency neuromuscular electrical stimulation (NMES) training on abdominal obesity in middle-aged women through electromyography and ultrasound. METHODS: Twenty-two middle aged women with abdominal obesity participated in the study. A low-frequency NMES device was used on the abdomen and waist of each subject for 20 minutes each (a total of 40 minutes) three times a week for eight weeks. The waist-hip ratio (WHR), weight and BMI (Body Mass Index) were measured. Electromyography (EMG) and ultrasound measurements were performed three times in total (pre-intervention, four weeks into the intervention, and eight weeks post-intervention) to examine the effects of low-frequency NMES on the abdominal muscle activity, muscle thickness, and subcutaneous fat. RESULTS: The results indicated a difference in the WHR and waist circumference before and after intervention (p<.05). The external oblique muscle (EO) showed a significant increase in muscle activity during all measurements taken post-intervention (p<.05). The abdominal subcutaneous fat thickness also showed a significant decrease between each measurement (p<.05). The test results showed that the abdominal subcutaneous fat thickness values taken eight weeks post-intervention were significantly lower than those taken pre-intervention and four weeks into the intervention (p<.05). CONCLUSION: These findings show that low-frequency NMES device training can be applied to middle-aged women with abdominal obesity to improve their body shape and exercise performance.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

Effects of Wole Body Vibration Training on Transverse Abdominis Muscle Thickness and Sitting Balance in Spastic Cerebral Palsy (전신진동 자극 훈련이 경직형 뇌성마비 아동의 배가로근 두께 및 앉은 자세 균형에 미치는 영향)

  • Hye-Lyeong Yun;Eun-Ju Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.1
    • /
    • pp.72-84
    • /
    • 2023
  • Background: The purpose of this study was to investigate the effect of whole-body vibration stimulation training on the thickness of the transversus abdominis muscle and the balance of sitting posture in children with spastic cerebral palsy. Design: Single-subject design(A-B-A-B). Methods: The subjects of this study were 9 children with spastic cerebral palsy. The study period was 12 weeks in total, and the baseline period and the intervention period were each assigned 3 weeks. Intervention was conducted twice a week for 30 minutes. During the baseline period, trunk stabilization exercise was performed, and during the intervention period, trunk stabilization exercise and whole-body vibration stimulation training were performed. Measurements were carried out at before the experiment, baseline 1, intervention 1, baseline 2, intervention 2 and the total number of measurements was 5 times. Repeated ANOVA was performed to compare the effects of exercise according to the intervention method. Results: The thickness of the transversus abdominis muscle and the balance of the sitting posture were statistically significantly increased compared to the baseline during whole-body vibration stimulation training (p<.05). Conclusion: Therefore, it was confirmed that whole-body vibration stimulation training improved the thickness of the transversus abdominis muscle in children with spastic cerebral palsy and was an effective intervention method for improving sitting posture balance.

Safety Assessment of Corrosion-damaged Steel Structure using Imprecise Reliability (불확실 신뢰도 기법을 이용한 부식된 강구조물의 안전도평가)

  • Choi, Hyun Ho;Cho, Hyo Nam;Seo, Jong Won;Sun, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.293-300
    • /
    • 2006
  • There is a high degree of uncertainty in measurements of the thickness or the loss of thickness of corroded elements. Generally the thickness of corroded elements varies from one location of the element to another depending on the degree of corrosion, which makes the safety assessment difficult. Therefore, a procedure for safety assessment of corrosion- damaged steel structures using an imprecise reliability is proposed in this paper. The proposed safety assessment procedure using the imprecise reliability was also applied to a cable-stayed bridge in Korea to demonstrate its effectiveness and applicability. Since there is a large variation in measurements of the thickness of corroded elements, the thickness of corroded elements was considered as the imprecise element. This variation was found to be directly related to the degree of corrosion. Therefore, the variation increases as the degree of corrosion increases. Based on the comparative observations between the conventional reliability and the imprecise reliability, it is suggested that the imprecise reliability analysis derived based on the subjective or statistical judgment of conditional independence could be successfully utilized for the risk or safety assessment of corrosion-damaged structures.

Stability of dental, alveolar, and skeletal changes after miniscrew-assisted rapid palatal expansion

  • Lim, Hyun-Mook;Park, Young-Chel;Lee, Kee-Joon;Kim, Kyung-Ho;Choi, Yoon Jeong
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.313-322
    • /
    • 2017
  • Objective: Miniscrew-assisted rapid palatal expansion (MARPE) is a means for expanding the basal bone without surgical intervention in young adults. Here, we assessed the differences in dental, alveolar, and skeletal measurements taken before (T0), immediately after (T1), and 1 year after (T2) MARPE. Methods: Twenty-four patients (mean age, 21.6 years) who had undergone MARPE and cone-beam computed tomography at T0, T1, and T2 were included. Changes in the following parameters were compared using paired t-tests: intercusp, interapex, alveolar, nasal floor, and nasal cavity widths; inclination of the first molar (M1) and its alveolus; and thickness and height of the alveolar bone. A linear mixed-effects model was used to determine variables that affected periodontal changes in the M1. Results: MARPE produced significant increases in most measurements during T0-T2, despite relapse of some measurements during T1-T2. The alveolar thickness decreased on the buccal side, but increased on the palatal side. The alveolar crest level at the first premolar moved apically. Changes in the thickness and height of the alveolar bone were affected by the corresponding initial values. Conclusions: MARPE can be used as an effective tool for correcting maxillomandibular transverse discrepancy, showing stable outcomes 1 year after expansion.

Age Estimation by Radiological Measuring Pulp Chamber of Mandibular First Molar in Korean Adults

  • Jeon, Hye-Mi;Kim, Jin-Hwa;Heo, Jun-Young;Ok, Soo-Min;Jeong, Sung-Hee;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.146-154
    • /
    • 2015
  • Purpose: The purpose of present study was to develop a method for assessing the chronological age of Korean adults based on the relationship between age and size of pulp cavity using dental radiographs of mandibular first molars. Methods: A total of 325 dental radiographs of Korean adults with known age and gender were selected for the study (199 males and 126 females) which were taken in the period between January 2009 and June 2014 at the Pusan National University Dental Hospital. The measurements were carried out on both orthopantomographs (OPGs) and intraoral periapical radiographs of mandibular first molar and the following ratios were calculated: pulp chamber floor height ratio (F/L), pulp chamber ceiling height ratio (R/L), and pulp chamber depth ratio (D/L). Results: The ratios of measurements on intraoral periapical images of mandible first molar generally produce more reliable data than the measurements on OPGs. The pulp chamber floor height ratio and pulp chamber thickness ratio showed significant correlation with age, whereas the pulp chamber ceiling height ratios showed weak correlation with age. It was found that the best correlations between the ratios and age were found for pulp chamber thickness ratios (r=-0.731 to -0.751). The multiple regression models were derived using 3 ratios that were significantly correlated with age. The determination coefficients ($R^2$) of the models ranged from 0.556 to 0.596. Conclusions: Our results indicate that the pulp chamber thickness and pulp chamber floor height in mandibular first molar are an age-dependent variable in adults which can be used to estimate age with reasonable accuracy. The higher image quality of dental radiographs will probably narrow the age estimation error and improve dental age estimation.