• Title/Summary/Keyword: Thermoluminescence Dosimetry

Search Result 26, Processing Time 0.019 seconds

Dosimetry of Irregular Field Using Thermoluminescence Dosimetry (부정형 조사면에서의 TLD를 이용한 방사선 흡수선량 측정)

  • Lee, Jong-Young;Park, Kyung-Ran;Kim, Kye-Jun
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.263-267
    • /
    • 1994
  • In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report describes an analysis of the dosimetry of the irregular fields such as radiation fields for Hodgkin's disease(mantle field), esophageal cancer, and lung cancer when a 6 MV and a 15 MV linear accelerators are utilized. Doses were measured in a Rando phantom using methods of thermoluminescence dosimetry(TLD), and were calculated by radiotherapy planning computer system with the Clarkson's method for calculation of a irregular field. A dose variation of $5-22\%,\;6-9\%,\;6-14\%$ were found in the mantle field, esophageal cancer field, lung cancer field respectively. Higher doses occurred in the superior portion of the irregular field. The sites of maximum dose variation were the supraclavicular and the upper spinal cord region. To adjust for these substantial differences, a compensator or a shrinking field technique should be adopted.

  • PDF

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

Gamma Dosimetry and Clinical Application with $Al_2O_3$ Thermoluminescent Dosimeter ($Al_2O_3$ 열형광(熱螢光) 특성(特性)을 이용(利用)한 감마선(線)의 측정(測定) 및 임상응용(臨床應用))

  • Chu, Seong-Sil;Park, Chang-Yoon
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.3-10
    • /
    • 1984
  • The properties of $Al_2O_3$ thermoluminescent phosphor have been observed to apply for gamma dosimetry in vivo. Glow peaks at 380, 420, 490 kelvin temperature with emission in the blue region have been detected and calculated as 1.4 eV the activation energy by means of heat response rising time method. Sensitization and supralinearity in $Al_2O_3$ phosphor could be consistently explained by the deep trap model. Studies of the thermoluminescence growth rate with gamma ray exposure showed linearly to $10^4$ Roentgen and then supralinear rate detected 1.2 power of exposure dose sensitization of $Al_2O_3$ is described five times more than TLD-100 and the fading time is shorter and then tried to apply for gamma dosimetry in vivo.

  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

In-vivo Dose verification using MOSFET dosimeter (MOSFET 선량계를 이용한 In-vivo 선량의 확인)

  • Kang, Dae-Gyu;Lee, Kwang-Man
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.102-105
    • /
    • 2006
  • In-vivo dosimetry is an essential tool of quality assurance programs in radiotherapy. The most commonly used techniques to verify dose are thermoluminescence dosimeter (TLD) and diode detectors. Metal oxide semiconductor field-effect transistor (MOSFET) has been recently proposed for using in radiation therapy with many advantages. The reproducibility, linearity, isotropy, dose rate dependence of the MOSFET dosimeter were studied and its availability was verified. Consequently the results can be used to improve therapeutic planning procedure and minimize treatment errors in radiotherapy.

Thermoluminescence of $MgCl_2$-Activated LiF Powder (불순물 $MgCl_2$를 첨가한 LiF 분말의 열형광)

  • 이계철;이상수
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.269-272
    • /
    • 1970
  • Thermoluminescence (TL) from LiF powder of purity 99.98 % was accomplished and this TL intensity showed glow peaks at 12$0^{\circ}C$, 22$0^{\circ}C$ and 30$0^{\circ}C$. Sintered LiF powder which has an activation of 2% proportion by weight of MgC1$_2$show strong increased TL and this characteristic of the glow curve was investigated precisely. LiF which is used in TL dosimetry has been known to have electrons caused by impurities such as Mg, Mn, etc. This experiment shows that Mg, one of the impurities, is definitely diffused through LiF crystals. The effects of sintering time were detected in this glow curve and it was confirmed that MgC1$_2$also has a TL effect.

  • PDF

A Study on the Dose Analysis of Pottery Shards by Thermoluminescence Dating Method (TL 연대측정법을 이용한 토기 시편의 선량 분석)

  • Shin, Hyun-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.558-564
    • /
    • 1999
  • A method for measuring archaeological dose of Packjae pottery shards using thermoluminescence dosimetry(TLD) has been studied. TL measurement has been achieved using quartz crystals in the size range of 90 to $125{\mu}m$ diameter extracted from the pottery shards. The stable temperature region of the TL glow curve which is devoid of anomalous fading components was identified by the plateau test and found to exist from 265 to $300^{\circ}C$. The archaeological dose of the pottery shards was estimated to be 7.43 Gy using the dose calibration curves obtained from sequential irradiation of $^{137}Cs$ gamma source to the samples and TL measurement of natural samples.

  • PDF

Development of Algorithm for Evaluation of the Dose with Thermoluminescence Dosimeter (열형광선량계에 의한 선량평가 알고리즘 개발)

  • Song, Myung-Jae;Kim, Hee-Keun;Ha, Chung-Woo;Lee, Tae-Young;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.2
    • /
    • pp.1-13
    • /
    • 1992
  • The purpose of this study is to develop an algorithm of TLD dose evaluation to meet all requirements stated in ANSI N13. 11-1983. It made the PB-3 TLD of Teledyne Isotopes an object of the development. Personal dosimetry performance testings of the development algorithm have been performed twice through the Atlan-Tech, INC. in accordance with the criteria of testing described in ANSI N13. 11-1983. As ,a result, it is assured that the developed algorithm has complied with all requirements stated in ANSI N13. 11-1983.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

Supralinearity of UV Irradiated Magnesium Aluminum Spinel (자외선 조사된 Magnesium Aluminum Spinel의 Supralinearity)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.202-206
    • /
    • 2005
  • Three-dimensional thermoluminescence (TL) spectra from $MgAl_2O_4$ irradiated with UV light were measured over 300${\~}$600 K and 300${\~}$800 nm. The peak positions of TL glow curves were shifted to lower temperature with increasing the exposure time of UV light. The 476 K TL glow curve is due to the second kinetics and its activation energy and escape frequency factor are calculated to be 0.85 eV and $1.92{\times}10^6 sec^{-1}$, respectively The TL spectra were split into 530 nm and 700 nm emission bands which were associated with $V^{2+}$ and $Cr^{2+}$, respectively. The linearity range of 700 nm omission band is smaller than that of 530 nm emission band, but the saturation time of 700 nm emission band is longer than that of 530 nm omission band.

  • PDF