• Title/Summary/Keyword: Thermographic images

Search Result 25, Processing Time 0.027 seconds

A Novel Model for Smart Breast Cancer Detection in Thermogram Images

  • Kazerouni, Iman Abaspur;Zadeh, Hossein Ghayoumi;Haddadnia, Javad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10573-10576
    • /
    • 2015
  • Background: Accuracy in feature extraction is an important factor in image classification and retrieval. In this paper, a breast tissue density classification and image retrieval model is introduced for breast cancer detection based on thermographic images. The new method of thermographic image analysis for automated detection of high tumor risk areas, based on two-directional two-dimensional principal component analysis technique for feature extraction, and a support vector machine for thermographic image retrieval was tested on 400 images. The sensitivity and specificity of the model are 100% and 98%, respectively.

Neurilemmoma of Deep Peroneal Nerve Sensory Branch : Thermographic Findings with Compression Test

  • Ryu, Seung Jun;Zhang, Ho Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.286-290
    • /
    • 2015
  • We report a case of neurilemmoma of deep peroneal nerve sensory branch that triggered sensory change with compression test on lower extremity. After resection of tumor, there are evoked thermal changes on pre- and post-operative infrared (IR) thermographic images. A 52-year-old female presented with low back pain, sciatica, and sensory change on the dorsal side of the right foot and big toe that has lasted for 9 months. She also presented with right tibial mass sized 1.2 cm by 1.4 cm. Ultrasonographic imaging revealed a peripheral nerve sheath tumor arising from the peroneal nerve. IR thermographic image showed hyperthermia when the neurilemoma induced sensory change with compression test on the fibular area, dorsum of foot, and big toe. After surgery, the symptoms and thermographic changes were relieved and disappeared. The clinical, surgical, radiographic, and thermographic perspectives regarding this case are discussed.

Infrared Thermographic Monitoring for Failure Characterization in Railway Axle Materials (철도차량 차축 재료의 파괴특성 적외선열화상 모니터링)

  • Kim, Jeong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • The wheelset, an assembly of wheel and axle, is one of important parts in railway bogie, directly related with the running safety of railway rolling stock. In this investigation, the tensile failure behavior of railway axle materials was investigated. The tensile coupons were prepared from the actual rolling stock parts, which were operated over 20 years. The tensile testing was performed according to the KS guideline. During tensile testing, an infrared camera was employed to monitor temperature changes in specimen as well as demonstrate temperature contour in terms of infrared thermographic images. The thermographic images of tensile specimens showed comparable results with mechanical behavior of tensile materials. In this paper, the failure mode and behavior of railway axle materials were provided with the aid of infrared thermography technique.

Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors (온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발)

  • Im, Yujin;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.

The Cut Off Values for Diagnosing Hot flashes by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 안면홍조 진단의 절단값 산정)

  • Jo, Jun-Young;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.3
    • /
    • pp.85-92
    • /
    • 2013
  • Objectives: The purpose of this study is to find diagnostic points and define the cut off values of hot flashes by using digital infrared thermographic imaging. Methods: Thermographic images of 75 patients with hot flashes (HF, n=35) and non-hot flashes (NHF, n=40) were retrospectively reviewed. We used the temperature difference between Ex-HN3 and CV17, LU4, CV12, CV4 for diagnosing hot flashes. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by received operating characteristic curve analysis. Analyses were undertaken using SPSS version 17.0. and p-value of <0.05 was considered significant. Results: The temperature difference Ex-HN3 and LU4 were the most significantly different between groups (p<0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 65.7%, 72.5%, 0.729, respectively. The optimum cut off value was defined as $1.00^{\circ}C$. Conclusions: These results suggest that the digital infrared thermographic imaging is a reliable instrument for estimating hot flashes.

The Cut Off Values for Diagnosing Cold Hypersensitivity of Hands by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 수부냉증 진단의 절단값 산정)

  • Jo, Jun-Young;Park, Kyoung-Sun;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.3
    • /
    • pp.95-102
    • /
    • 2012
  • Purpose: The purpose of this study is to define the cut off values of cold hypersensitivity of hands by using digital infrared thermographic imaging(DITI). Methods: Thermographic images of 130 patients with cold hypersensitivity of hands(CHHG, n=65) and non-cold hypersensitivity of hands(NCHHG, n=65) were retrospectively reviewed. We used the temperature difference the palm(PC8) and the upper arm(LU4) for diagnosing cold hypersensitivity of hands. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by ROC curve analysis. Analyses were undertaken using SPSS version 17.0. P value of < 0.05 was considered significant. Results: The temperature difference the palm(PC8) and the upper arm(LU4) were significantly different between groups(p < 0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 70.8%, 73.8%, respectively both hands. The AUC was 0.822 on right hand and 0.818 on left hand. The optimum cut-off value was defined as $-0.05^{\circ}C$. Conclusions: These results suggest that DITI is a reliable instrument for estimating the cold hypersensitivity of hands.

The Clinical Observation of Diagnostic value in Bell's palsy with Digital infrared Thermal Imaging (구안와사환자에서 D.I.T.I.의 진단적 가치에 대한 임상고찰)

  • Oh, Sang-Deog;Lim, Seung-Man;Baek, Eun-Tan;Kim, Young-Tae;Hong, Sae-Young;Ra, Su-Yeon;Shin, Hyoun-Su
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.573-578
    • /
    • 2001
  • Objective: This study was carried out to investigate the correlation between prognosis and differential temperature of Digital infrared Thermographic Imaging in Bell's palsy. Methods: The clinical data and thermographic images were analyzed on 50 cases of Bell's palsy who were treated ambulatory in Dong-so oriental hospital from October 2000 to May 2001 And 32case were selected who underwent thermographic imaging within 7days of onset. Results: There was no statistic significance between ${\Delta}T$ and the length of treatment, but the length of treatment tends to grow as ${\Delta}T$ increased. The length of treatment was shortest in normal thermal pattern, followed by hyperthermal and hypothermal. Conclusions: According to the results, there was a tendency that ${\Delta}T$ value is proportional to treatment days, although it is not significant statistically.

  • PDF

The use of infrared thermography to detect the stages of estrus cycle and ovulation time in anatolian shepherd dogs

  • Olgac, Kemal Tuna;Akcay, Ergun;Cil, Beste;Ucar, Burak Mehmet;Daskin, Ali
    • Journal of Animal Science and Technology
    • /
    • v.59 no.10
    • /
    • pp.21.1-21.6
    • /
    • 2017
  • Background: The aim of the study is to evaluate the effectiveness of thermographic monitoring, using the temperature changes of perianal and perivulvar areas for the determination of estrus in Anatolian Shepherd bitches. Fifteen bitches were used in the study. Blood and vaginal smear samples were collected and thermographic monitoring of perianal and perivulvar areas were carried out starting from proestrus to early diestrus. Also, external signs of estrus were investigated. Smear samples were evaluated by light microscopy after Diff-Quik staining method and superficial and keratinized superficial cells were determined as percentage (S + KS%). Progesterone and luteinizing hormone measurements were done by radioimmunoassay. The difference in temperature between perianal and perivulvar areas was evaluated through thermographic images by FLIR ResearchIR Software. Results: According to the results obtained from the study, differences between progesterone and S + KS% were statistically significant (P < 0,05). Although temperature showed increase and decrease with progesterone and S + KS%, the differences were not important statistically (P > 0,05). Serum luteinizing hormone levels did not sign any difference (P > 0,05). Conclusions: As a result, thermographic monitoring alone is not enough for estrus detection in Anatolian Shepherd bitches. However, it can be used to assist the actual estrus detection technique in terms of providing some foreknowledge by evaluating the differences in temperature.

The Clinical Experience with Computer Aided Thermography during Treatment of Bell's Palsy (안면신경마비환자의 치료경과에 대한 Computer Aided Thermogrpahy를 이용한 관찰)

  • Lee, Kyu-Chang;Lee, Jin-Kyung;Woo, Nam-Sik;Lee, Ye-Chul
    • The Korean Journal of Pain
    • /
    • v.4 no.1
    • /
    • pp.47-50
    • /
    • 1991
  • Bells palsy is a usually innocuous but psychologically distressing disease. The majority of cases are of the so-called idiopathic type, the etiology of which is unknown. This 52 year-old female patient was treated with repeated stellate ganglion bupivacaine blocks, acupuncture and transcutaneous electric nerve stimulation, with return of function. In our case studies, using thermographic images to diagnosis and to evaluate objective assessment of treatment of Bells palsy, we observed the correlation between neurologic symptoms and thermographic image.

  • PDF

Fabrication of [320×256]-FPA Infrared Thermographic Module Based on [InAs/GaSb] Strained-Layer Superlattice ([InAs/GaSb] 응력 초격자에 기초한 [320×256]-FPA 적외선 열영상 모듈 제작)

  • Lee, S.J.;Noh, S.K.;Bae, S.H.;Jung, H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • An infrared thermographic imaging module of [$320{\times}256$] focal-plane array (FPA) based on [InAs/GaSb] strained-layer superlattice (SLS) was fabricated, and its images were demonstrated. The p-i-n device consisted of an active layer (i) of 300-period [13/7]-ML [InAs/GaSb]-SLS and a pair of p/n-electrodes of (60/115)-period [InAs:(Be/Si)/GaSb]-SLS. FTIR photoresponse spectra taken from a test device revealed that the peak wavelength (${\lambda}_p$) and the cutoff wavelength (${\lambda}_{co}$) were approximately $3.1/2.7{\mu}m$ and $3.8{\mu}m$, respectively, and it was confirmed that the device was operated up to a temperature of 180 K. The $30/24-{\mu}m$ design rule was applied to single pixel pitch/mesa, and a standard photolithography was introduced for [$320{\times}256$]-FPA fabrication. An FPA-ROIC thermographic module was accomplished by using a $18/10-{\mu}m$ In-bump/UBM process and a flip-chip bonding technique, and the thermographic image was demonstrated by utilizing a mid-infrared camera and an image processor.