• Title/Summary/Keyword: Thermographic change

Search Result 52, Processing Time 0.027 seconds

Study on facial thermographic change of D.I.T.I. by acupuncture on Zusanli(ST36) (적외선(赤外線) 체열(體熱) 촬영(撮影)을 이용한 족삼리(足三里)(ST36)자침(刺鍼)이 안면부(顔面部) 영역간(領域間) 온도차이(溫度差異)의 변화(變化)에 미치는 영향(影響))

  • Cho, Eun-hee
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.107-117
    • /
    • 2003
  • Objective: This study was examined for effects of acupuncture of Zusanli(ST36) on the facial thermography in health subjects. Methods: The voiunteers who participating in this study had taken rest for 15 mins in room temperature ($19-21^{\circ}C$) before the examination and informed them what to prohibit smoking. drinking and administration of drug for the previous day. The thermography of face was taken using Digital Infrared Thermographic Imaging (D.I.T.I.: Dorex. DTI-16UT1. U.S.A.) by time interval of 35 minutes at 15 min before and 20 min after acupuncture stimuiation. Thermal temperature of Daying(ST5). Juliao(ST3) and Quanliao(SI18) was measured and compared. Results: The results showed that acupuncture of Zusanli(ST36) significantly decreased the Absolute defference of temperature between Daying(ST5) and Juliao(ST3) (p<0.05, Data were represented meant ${\pm}$S.E.M.(n=33)). The results showed that acupuncture of Zusanli(ST36) significantly decreased the Absolute defference of temperature between Quanliao(SI18) and Juliao(ST3)(p<0.01, Data were represented mean${\pm}$S.E.M. (n=33)). But, acupuncture of Zusanli(ST36) particularly decreased the absolute defference of temperature between Daying(ST5) and Quanliao(SI18). Also. it was observed that acupuncture of ST36 decreased variety of the color tone of thermographic contour line and decreased thermal distribution. Conclusions: The results showed that acupuncture of Zusanli(ST36) significantly decreased the absolute defference of temperature of partial facial surface. Hereafter. study about if acupuncture of Zusanli(ST36) significantly decrease the absolute defference of temperature of all the areas of facial surface is requested. Also. continued study of effects of acupuncture of other meridian on the facial thermography is requested.

  • PDF

Characteristics of Acupuncture at Chok-Samni(ST36) on Facial Thermographic Change of D.I.T.I. (D.I.T.I.를 이용한 족삼리(ST36)자침이 안면부 절대온도변화에 미치는 영향)

  • Cho Eun Hee;Park Min Cheol;Choi Deok Hwa
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.6
    • /
    • pp.1493-1499
    • /
    • 2003
  • This study was examined for effects of acupuncture of Chok-Samni(ST36) on the facial thermography in health subjects, The volunteers who participating in this study had taken rest for 15 mins in room temperature (19-21 ℃) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day, The thermography of face was taken using Digital Infrared Thermographic Imaging (D.I.T.I. : Dorex, DTI-16UT1, U.S.A.) by time interval of 35 minutes at 15 min before and 20 min after acupuncture stimulation. Thermal temperature of Yangbaek(GB14), Myon-koryo(ST3) and Chichang(ST4) was measured and compared, The results showed that acupuncture of Chok-Samni(ST36) decreased the Absolute difference of temperature between Myon-koryo(ST3) and Chichang(ST4) (p<0,05, Data were represented mean±S,E.M.(n=33)), But, acupuncture of Chok-Samni(ST36) particularly decreased the absolute difference of temperature between Yangbaek(GB14) and Chichang(ST4) and particularly decreased the absolute difference of temperature between Vangbaek(GB14) and Myon-koryo(ST3) (p<0,05, Data were represented mean±S,E.M.(n=33)). Also, it was observed that acupuncture of Chok-Samni(ST36) decreased variety of the color tone of thermographic contour line and decreased thermal distribution. The results showed that acupuncture of Chok-5amni(ST36) significantly decreased the absolute difference of temperature of partial facial surface. Hereafter, study about if acupuncture of Chok-Samni(ST36) significantly decrease the absolute difference of temperature of all the areas of facial surface is requested. Also, continued study of effects of acupuncture of other meridian on the facial thermography is requested.

Thermographic Evaluation of Beating Process of Experimentally Induced Infectious Arthritis in Horses (실험적으로 유발한 말 감염성 관절염의 치유경과에 대한 체열학적 평가)

  • Yang Young-Jin;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.22-30
    • /
    • 2006
  • This study was carried out to assess the usefulness of thermography for diagnosis and healing process of musculoskeletal disorder in horses. Horses with experimentally induced infectious arthritis were treated with bee venom or antibiotics for 5 weeks from 24 hours after inoculation of Staphylococcus aureus, the effectiveness of the 2 therapeutic drugs treatment was similar to each other. Thermographic evaluation was similar to any other tests, because the thermal pattern tend to return to normal with declining similar to those of clinical signs, laboratory experiments and healing of the lesion. This ability to assess inflammatory change noninvasively make thermography an ideal imaging tool to aid in the diagnosis of certain lameness condition or musculoskeletal disease in horses. These results suggested that thermographic evaluation in horses with musculoskeletal disorders were useful for diagnosis and helpful for monitoring of healing process.

Thermographic Finding at Splanchnic Nerve Block for Cancer Pain (암성 상복부 통증 환자의 내장신경 차단시 관찰한 체열촬영 소견)

  • Lee, Sang-Hun;Woo, Nam-Sik;Lee, Ye-Chul
    • The Korean Journal of Pain
    • /
    • v.7 no.1
    • /
    • pp.59-64
    • /
    • 1994
  • Splanchnic nerve block is effective in relief of upper abdominal cancer pain. But we often get confused at the unexpected complaints of pain accompanying a metastatic of referred origin in spite of the precise block under image intensifier. We could found aut a thermographic change from the diffuse hyperemission state of abdomen before the block to the localized state after the block. It may be helpful in differentiating objectively the accuracy of the block at the unexpected complaints of pain by using thermography before and after the block.

  • PDF

Effect of Aceclofenac on the Skeletal Muscle (Aceclofenac이 골격근 형태에 미치는 효과)

  • Song, Myung-Soo;Kim, Tea-Yeal;Yoon, Hee-Jong;Jang, Ki-Yen
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.597-605
    • /
    • 2000
  • There has been several usual ways to cure pain in osteological muscle: use oral medicine or injection, or apply medicine to a sore place. The purpose of this study was to examine, by using thermometer and digital infrared thermographic imaging, how much the permeation of aceclofenac, an anodyne and antiphlogistic, into sore skin brought a change to skin temperature after that was' applied to it. The findings of this study were as below; 1. A cream made of aceclofenac yielded $0.61^{\circ}C$ difference in temperature, but the difference wasn't statistically significant. 2. An aceclofenac to which oleic acid was added went through microemulsion and applied, and there was $0.3^{\circ}C$ change in temperature, the biggest significant difference(P<.05), after approximately 15 minutes passed. 3. An aceclofenac to which labrasol was added went through microemulsion and applied, and there was a growing rise in temperature with the lapse of time. After 30 minutes passed, the final temperature showed $1.25^{\circ}C$ rise, which was a significant change(P<.05). 4. As the temperature was measured by digital infrared thermographic imaging, there was about $3.97^{\circ}C$ fall, the biggest change, which was significant(P<.05). The findings of this study suggested that the application of aceclofenac to sore skin caused a change in skin temperature, as that permeated into it.

  • PDF

Thermographic Study on Effectiveness of Acupuncture, Electro-Acupuncture and Acupuncture with Pulsed Electromagnetic Therapy on Upper Extremity of Healthy and Hemiplegic Group (건강인군과 편마비군에 시행한 침, 전침 및 박동성 전기자장 치료가 상지의 체열 변화에 미치는 영향)

  • Lee, Jong-Ha;Song, Mi-Young;Keum, Dong-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.2
    • /
    • pp.85-96
    • /
    • 2016
  • Objectives This study was performed to evaluate the effects of acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy on upper extremity of healthy people and hemiplegic patients by D.I.T.I.. Methods 20 healthy people and 20 hemiplegic patients caused by stroke were selected. They have been treated three different types of treatment; acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy. And skin temperature of upper extremity has been measured before and after each treatment by D.I.T.I.. The thermographic data was analyzed by 'Independent T-test' and 'Repeated measures ANOVA test'. Results 1. In healthy group, there was very statistical significant difference (p<0.001) of the amount of thermal change by each treatment, and the amount of change was arranged in descending order; acupuncture with pulsed electromagnetic, acupuncture and electro-acupuncture. 2. In hemiplegic group, the skin temperature of hemiplegic side was $0.97^{\circ}C$ cooler than non-hemiplegic side. 3. Skin temperature of all hemiplegic patients was increased after acupuncture treatment. 4. In hemiplegic group, there was statistical significant difference (p<0.05) of the amount of thermal change by each treatment, and the amount of change was arranged in descending order; acupuncture with pulsed electromagnetic, acupuncture and electro-acupuncture. Conclusions The results indicate that acupuncture, electro-acupuncture and acupuncture with pulsed electromagnetic therapy had good effect on the change of skin temperature by stimulating sympathetic nervous system.

A Study on the Change of Digital Infrared Thermographic Imaging and Skin Resistance Variability before and after Treatment of Dysmenorrhea (월경통 치료 전과 후의 적외선체열영상 및 피부저항변이도 변화에 대한 연구)

  • Kim, Hyeon-Ju;Lee, Yong-Hyun;Sohn, Young-Joo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.2
    • /
    • pp.88-103
    • /
    • 2013
  • Purpose: The aim of this study was to examine the effect of oriental diagnosis and treatment for dysmenorrhea patients on lower abdominal temperature and Skin Resistance Variability(SRV). Methods: We studied twenty-five dysmenorrhea patients, who visited Oriental Medicine Hospital of ${\bigcirc}{\bigcirc}$ University for 10 months(Sep. 2011~Jun. 2012). Patients with organic disease such as endometriosis, uterine myoma and pelvic inflammatory disease were excluded from this study. We prescribed 3 types of treatments, herbal medicine, acupuncture, and moxibustion, for one menstrual cycle. Digital Infrared Thermographic Imaging(DITI), 7-Zone-Diagnostic System(CP-6000A), VAS(Visual analog scale) and MVRS(Multidimensional verbal rating scale) were conducted before and after the treatment. The result of DITI, 7-Zone-Diagnostic System, VAS and MVRS before and after treatment were compared in order to objectively assess the therapeutic effect. Results: When we compared the results of DITI, CV4 temperature after treatment was increased compared with that of before, and temperature difference between CV12 and CV4 after treatment was decreased compared with that of before. But there was no significant difference. When we compared the results of 7-Zone-Diagnostic System at 1st and 2nd trial, the height of 1~5 area was lower than that of before. And at 1st and 2nd trial, the height of 6, 7 area was higher than that of before, but there were no significant difference in most. When we compared the results of VAS and MVRS, VAS and MVRS after treatment was significantly decreased compared with that of before(p<0.01). Conclusions: This study shows that oriental diagnosis and treatment for dysmenorrhea patients affects the results of DITI. Further study will be needed.

Thermographic Inspection of Fatigue Crack by Using Contact Thermal Resistance (접촉 열저항 효과를 이용한 피로균열의 적외선검사)

  • Yang, Seungyong;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.187-192
    • /
    • 2013
  • Fatigue crack was detected from a temperature change around surface crack using the thermographic technique. Thermal gradient across the crack decreased very much due to thermal resistance of contact surface in the crack. Heat diffusion flow passing through the discontinuity was visualized in temperature by infrared camera to find and locate the crack. A fatigue crack specimen(SM-45C), which was prepared according to KS specification and notched in its center to initiate fatigue crack from the notch tip, was heated by halogen lamp at the end of one side to generate a heat diffusion flow in lateral direction. A abrupt jump in temperature across the fatigue crack was observed in thermographic image, by which the crack could be located and sized from temperature distribution.

Thermographic Findings in Craniomandibular Disorders ; Clinical Evaluation (두개하악장애환자의 임상적 평가를 위한 컴퓨터적외선체열검사)

  • Ick-Joo Cho;Jung-Pyo Hong;Sang-Rae Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.477-487
    • /
    • 1995
  • The purpose of this study was to assess the thermographic differences of craniomandibular area between normal individual and patients with craniomandibular disorders and to compare the differences between clinical and thermographical assessment. The author had used 50 subjects as materials for this study, which was divided into 2 groups (first group included 15 healthy subjects and second group included 35 patients) with craiomandibular disorders; 17 subjects had normal disc-condyle relationship, 13 subjects had disc displacement with reduction and 5 subjects had disc displacement without reduction. Agema 870 thermovision(D.I.T.I.) was used to take thermographs with $0.1^{\circ}C$ difference of gradual temperature shift. The results were as follows : 1. Of 34 patients with craniofacial pain, 15(44%) subjects showed hyperthermia on the pain site in the thermography, 8(23.5%)exhibited hyperthermia on the site opposed to the pain site, and 11(32.4%) did not show any significant thermal change. One patient without craniofacial pain showed hyperthermia on the site opposed to the site of disc displacement without reductin. 2. Of 35 patients with craniofacial pain or disc displacement, 24(68.6%) subjects showed a significant thermal difference between symptomatic and asymptomatic sides of the face, but 11(31.4%) did not show any difference. 3. Of 17 patients with pain but with normal disc-condyle relationship, 8(47.1 subjects showed hyperthermia on the pain site, 4(23.5%) showed on the site opposed to the pain site, and 5(29.4%) did not show any significant thermal change. 4. Or 13 patients with pain and disc displacement with reduction, 6(46.2%) subjects showed hyperthermia on the pain site, 3(23.1%) showed on the site opposed to the pain site, and 4(30.8%) did not show any significant thermal change. 5. 15 healthy subjects did not show any thermal differences between the both sides of the face.

  • PDF

Study on the possibility of Digital Infrared Thermographic Imaging as a prognosis evaluation tool for patients with facial palsy (안면신경마비 환자의 예후 평가 도구로서의 적외선 체열 촬영(DITI - Digital Infrared Thermographic Imaging) 가능성에 대한 연구)

  • Bae, Hyo-Bin;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.3
    • /
    • pp.62-75
    • /
    • 2017
  • Objectives : The aim of this study is to evaluate possibility of DITI as prognosis evaluation tool of facial palsy. Methods : We investigate prognosis of facial palsy through EMR(Electronic Medical Record) of inpatient from December 2016 to June 2017. We evaluated the sex, age distribution, length of hospital stay, paralysis site, number of treatment after discharge, change of H-B Grade at entrance and exit, temperature difference of both sides of DITI, and Nerve Conduction Study(NCS) with reference to EMR recorded symptom change. Results : 1. Significant correlations were not found between DITI and House-Brackmann Grade change, NCS(%), the date of admission. 2. There was a negative correlation between NCS(%) and hospitalization period in patients with facial palsy. The higher the NCS, the faster the recovery rate of facial palsy. 3. In patients with facial palsy, the temperature difference between the two sides after the DITI image shows that the affected side tends to be lower than the normal side. Conclusions : In this study, only DITI temperature difference between both sides of face is not significant in determining the prognosis of facial palsy. Further research is needed to conduct DITI at the same time and to improve accuracy through a sufficient assessment of the degree of facial palsy.