• 제목/요약/키워드: Thermoelectric Energy

검색결과 234건 처리시간 0.023초

DMFC 시스템에 사용한 열전 변환기에 관한 연구 (A Study on Thermoelectric Converter Using DMFC (Direct Methanol Fuel Cell) System)

  • 장경량;문채주;장영학;정의헌;김태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.92-94
    • /
    • 2007
  • This article describes a thermoelectric converter, which is powered by thermoelectric (TE) power modules. This system uses TE devices that directly convert heat energy to electricity to power a converter using direct methanol fuel ceil (DMFC) system. The characteristics of the TE module were tested at different temperatures. A boost BC-DC converter was designed and controlled by a power-supply controller chip. Efficiency of about 80% can be achieved and because the thermoelectric converter system has not moving parts and has a small volume, the system can be carried about easily and conveniently to supply portable electric equipment and this is very important for some mobile equipment.

  • PDF

방사성동위원소 열전 발전기 최적설계를 위한 차폐 및 열전달 해석 (Heat Transfer and Radiation Shielding Analysis for Optimal Design of Radioisotope Thermoelectric Generator)

  • 손광재;홍진태;양영수
    • 대한기계학회논문집A
    • /
    • 제37권12호
    • /
    • pp.1567-1572
    • /
    • 2013
  • 방사성동위원소 열전발전기는 장반감기 알파 혹은 베타 핵종에서 방출하는 하전입자를 차폐하여 방사선에너지를 열에너지로 전환하고 이때 발생하는 열전재료의 온도차를 이용하여 전력을 생산하는 시스템이다. 이 기술은 에너지 밀도가 높고 수명이 길며 신뢰성이 높아 우주개발, 국방 등 극한 환경에서 사용되는 장치, 센서 및 로봇 등의 에너지원으로 그 효용성이 매우 높다. 본 연구에서는 방사선 차폐해석 및 열전달 해석을 통하여 차폐체, 그리고 최대 온도구배를 가지는 열전재료의 형상과 배치를 결정하여 열전발전기 기초설계를 도출하였다.

집중 태양열에 의한 온도구배가 열전발전모듈의 출력 성능에 미치는 영향 (Influence of temperature gradient induced by concentrated solar thermal energy on the power generation performance of a thermoelectric module)

  • 최경후;안다훈;부준홍
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.777-784
    • /
    • 2017
  • 일반적으로 열전발전 소자를 사용하여 에너지 하베스팅을 하는 경우, 시스템의 작동환경에 의해 주어지는 온도구배를 활용하게 된다. 따라서 열전소자의 특성상 큰 온도구배를 기대하기 어려운 작동환경에서는 원하는 출력을 얻을 수 없으며, 작동 온도가 높을 때 얻어지게 되는 최적의 발전효율을 기대하기 힘들다. 자연환경에서 얻을 수 있는 태양에너지를 활용한 신재생 에너지의 활용은 그 동안 태양광발전이나 태양열발전에 국한되어 왔다. 태양광발전은 태양광의 일정 파장대만 사용하고 빛의 산란에 의해 발전효율이 낮아지는 단점이 있으며, 태양열발전은 일반적으로 대규모 설비를 갖춰야 하는 공간상의 제약이 있다. 본 연구에서는 태양열을 집광하여 열전소자에 조사함으로서 큰 온도구배를 형성하여 상용 열전소자의 출력을 향상시킬 수 있는 간단한 소형 발전시스템을 설계 및 제작하였다. 장시간 태양열 집중을 위해 태양 추적 장치를 설치하였으며, 열전소자 하부에 고온의 태양열이 전달되어 온도 편차가 줄어드는 현상을 막기 위해 액체 순환식 냉각기를 설치하여 큰 온도구배를 유지할 수 있도록 설계한 후, 일련의 실험으로 시험하여 그 유용성과 타당성을 검증하였다.

Spark Plasma Sintering 법으로 제조한 CoSb3 Skutterudite계 열전소재의 n형 첨가제 효과 (Effect of n-type Dopants on CoSb3 Skutterudite Thermoelectrics Sintered by Spark Plasma Sintering)

  • 이재기;최순목;이홍림;서원선
    • 한국재료학회지
    • /
    • 제20권6호
    • /
    • pp.326-330
    • /
    • 2010
  • $CoSb_3$ Skutterudites materials have high potential for thermoelectric application at mid-temperature range because of their superior thermoelectric properties via control of charge carrier density and substitution of foreign atoms. Improvement of thermoelectric properties is expected for the ternary solid solution developed by substitution of foreign atoms having different valances into the $CoSb_3$ matrix. In this study, ternary solid solutions with a stoichiometry of $Co_{1-x}Ni_xSb_3$ x = 0.01, 0.05, 0.1, 0.2, $CoSb_{3-y}Te_y$, y = 0.1, 0.2, 0.3 were prepared by the Spark Plasma Sintering (SPS) system. Before the SPS synthesis, the ingots were synthesized by vacuum induction melting and followed by annealing. For phase analysis X-ray powder diffraction patterns were checked. All the samples were confirmed as single phase; however, with samples that were more doped than the solubility limit some secondary phases were detected. All the samples doped with Ni and Te atoms showed a negative Seebeck coefficient and their electrical conductivities increased with the doping amount up to the solubility limit. For the samples prepared by SPS the maximum value for dimensionless figure of merit reached 0.26, 0.42 for $Co_{0.9}Ni_{0.1}Sb_3$, $CoSb_{2.8}Te_{0.2}$ at 690 K, respectively. These results show that the SPS method is effective in this system and Ni/Te dopants are also effective for increasing thermoelectric properties of this system.

매트용 냉난방 시스템 개발 (Development of Cooling and Heating System for Matt)

  • 조현섭
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2008년도 춘계학술발표논문집
    • /
    • pp.163-166
    • /
    • 2008
  • This study developed matt used by thermoelectric device to use both cooling and heating. To develop this system, heating system used sheath heater and cooling system used thermoelectric device. A Flow of water controlled by a capillary tube system made by polymethyl. Results by this system very lowered spending of energy.

  • PDF

열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석 (The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers)

  • 이태희
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

고온열전모듈용 금속유리계 페이스트 연구 (Research for Solder Paste in Metallic Glass System for Thermoelectric Modules)

  • 서승호;손근식;서강현;최순목
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.249-254
    • /
    • 2018
  • We researched about a bulk metallic glass system as an additive to an Ag paste for high temperature thermoelectric modules. Bulk metallic glass (BMG) ribbons were produced by using a rapid solidification process (RSP) under a cooling rate condition higher than $10^{\circ}C/sec$. We investigated BMG characteristics of the ribbons by means of x-ray diffraction (XRD) and differential scanning calorimetry (DSC) in order to evaluate the glass transition temperature ($T_g$) and the recrystallization temperature ($T_x$) lower than $400^{\circ}C$. A milling process was also developed to apply the BMG ribbons to a commercial Al paste as an additive for lower sintering temperature.

열전소자의 열적조건 변화에 따른 발전 특성 (Performance of Thermoelectric Power Generator with Various Thermal Conditions)

  • 한훈식;김명기;엄석기;김서영
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.165-170
    • /
    • 2010
  • Experiments have been performed to investigate the key parameters determining the performance of thermoelectric power generation. The experimental results obtained show that the power output significantly increases with the temperature difference between cold and hot sides of thermoelectric generator. However, the effect of the hot side temperature under the identical temperature difference on the overall performance of a thermoelectric generator is meager. The conversion efficiency defined as the ratio of the power generated to the heat absorbed at the hot side increases with the temperature difference. The behavior of the thermoelectric generator is shown to be consistent with the theoretical analysis. The optimum current giving the maximum conversion efficiency and the maximum conversion efficiency are linearly increased with the temperature difference.

공랭식 열교환핀이 부착된 열전모듈의 냉각 성능에 관한 연구 (Cooling Performance of Thermoelectric Module with Air-Cooled Heat Exchanger Fins)

  • 신재훈;한훈식;김윤호;김서영;현재민
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.171-179
    • /
    • 2010
  • Thermal performance of louver fin and plate fin in a thermoelectric cooling system with a duct-flow type fan arrangement is analytically evaluated. The thermoelectric cooling system consists of a thermoelectric module and two heat exchanger fins. The analytic results show that the optimized louver fin has lower thermal resistance than plate fin. The COP and heat absorbed rate of the thermoelectric cooling system with optimized louver fins are 10.3% and 5.8% higher than optimized plate fins, respectively.