• Title/Summary/Keyword: Thermoacoustic Refrigerator

Search Result 17, Processing Time 0.02 seconds

Numerical Simulation and Analysis for Optimum Design of a Thermoacoustic Refrigerator (공명관식 열음향 냉동기의 최적설계를 위한 수치모사 및 설계인자 분석)

  • Kim, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.329-340
    • /
    • 1995
  • Basic refrigeration effect and efficiency of a thermoacoustic refrigerator is studied. The refrigerator model for numerical simulation is composed of half wavelength resonator and appropriate stack of plate. Theoretical model for thermoacoustic refrigeration suggested by Swift et. al is adapted for numerical calculation. The model contains arbitrary viscosity effect of the gas filled in the resonator. The wave equation is integrated by using 4-th order Runge-Kutta algorithm to give pressure distribution along the stack of plate. Heat flux and COP are also calculated based on the energy flux equation. By analyzing the numerical simulation results, optimum values of design parameters for thermoacoustic refrigerator are obtained.

  • PDF

The Performance Investigation of 1/4 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant (헬륨을 냉매로 사용한 1/4파장 열음향 냉동기의 성능 평가)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.52-57
    • /
    • 2002
  • In this study, a thermoacoustic refrigerator, using a resonant standing acoustic wave. has been built. The refrigerant is helium gas. The description of thermoacoustic refrigerator was Presented. The temperature ratio (cold part temperature over hot part temperature) and the COP (Coefficient of Performance) that normalized by carnot's COP are plotted versus the thermal load applied to the cold end, for- various speaker power.

An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/4 wave (1/4파장 열음향 냉동기의 공명관 길이 의존 특성 연구)

  • Song, Kyu-Joe;Park, Jong-Ho;Koh, Deuk-Yong;Park, Seong-Je
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.229-234
    • /
    • 2001
  • The thermoacoustic refrigerator bas not only considerable possibility but also commercial usability, because it bas high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying length of the resonance tube to 400mm, 500mm, 600mm, 700mm. In order to determine the optimum resonance tube length and the frequency, the $\lambda/4$ thermoacoustic engine and the similar apparatus of Wheatly type refrigerator were constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $56.3^{\circ}C$ at 626Hz in 400mm tube with 40mm stack.

  • PDF

An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/2 wave (1/2파장 열음향 냉동기의 공명관 길이 의존 특성 연구)

  • Song, Kyu-Joe;Park, Jong-Ho;Koh, Deuk-Yong;Kim, Hyo-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.217-222
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying the length of Resonant Tube to 400mm $\sim850mm$. In order to determine the optimum position of stack in the resonance tube and the frequency, the simple $\lambda/2$ thermoacoustic refrigerator was constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $52.6^{\circ}C$ at 827Hz in 400mm tube with 40mm stack.

  • PDF

The Construction and Investigation of The 1/4 Wavelength Thermoacoustic Refrigerator (1/4파장 열음향 냉동기의 제작 및 성능시험)

  • Song, Kyu-Joe;Park, Jong-Ho;Lee, Sung-Ro;Lee, Jae-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.223-228
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, The thermoacoustic refrigerator were constructed. The apparatus is capable of driving closed systems containing He or air at mean pressures ranging from 1-9.3 bar, at frequencies ranging from 100-1000Hz. The resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, The resonance tube is 340.5mm in length. In case of using air as a coolant. Freezing frequency is 174Hz, In case of using He as a coolant Freezing frequency is 625Hz. Using He, The cold-part temperature of the heat exchanger fell to $-23.7^{\circ}C$ after 120 minutes in 70W.

  • PDF

An Experimental Study on the Frequency and Pressure Variation of a Closed-tube-type Thermoacoustic Refrigerator (밀폐관형 열음향 냉동기의 주피수 및 압력변화 연구)

  • Song, Gyu-Jo;Park, Jong-Ho;Go, Deuk-Yong;Park, Seong-Je;Kim, Hyo-Bong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.15-21
    • /
    • 2001
  • A thermoacoustic refrigerator has not only considerable feasibility but also commercial usability, because it has high reliability, lower vibration, no moving part. and easy construction. In the present study, the resonant characteristics of a thermoacoustic refrigerator, varying the length of resonant tube from 400mm to 850mm, were investigated to improve performance. In order to determine the optimum position of the stack in the resonant tube and the optimum frequency, the simple open-tube-type thermoacoustic refrigerator was constructed. Air was used as a coolant. In the fifth harmonic, the largest $\DeltaT$ was $52.6^{\circ}C$ at 827Hz, tube length of 400mm, and stack length of 40mm.

  • PDF

An Experimental Study on the 1st Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (개방관형과 밀폐관형 열음향 냉동기의 1차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;정철진
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.189-192
    • /
    • 2002
  • In this study, The experimental open-tube-type and close-tube-type thermoacoustic refrigerator were constructed. The resonant characteristics of a thermoacoustic refrigerator were investigated. In order to determine the optimum resonant tube length and frequency, We changed the length of resonant tube from 400mm to 850mm and the frequency from 100Hz to 1000Hz. In case of first harmonic, the temperature difference of open-tube-type (1/4 wave) refrigerator was $41^{\circ}C$(resonator length :500mm). The temperature difference of close-tube-type (1/2 wave) refrigerator was $43^{\circ}C$(resonator length :850mm). In this experiments, the experimental 1/2 wave refrigerator is slightly cooler than the experimental l/4 wave refrigerator.

  • PDF

The Performance Investigation of Double-speaker-1/2 Wavelength Thermoacoustic Refrigerator (Double speaker 1/2파장 열음향 냉동기의 성능 평가)

  • Song Kyu Joe;Park Jong Ho;Lee Sung Ro
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.647-650
    • /
    • 2002
  • A thermoacoustic refrigerator, using a resonant standing acoustic wave, has been built. It employs a loudspeaker to sustain a standing wave in a resonance tube. The stack of plates is 0.075mm-thick plastic sheet(Mylar), spirally wound to make a 40mm-diameter assembly 80mm long. and two heat exchanger are installed. The refrigerant is Helium gas. The description of thermoacoustic refrigerator are presented. The directly measured performance of the resonator. Tc/Th ( temperature ratio ) and $COP/COP_{c}$, (normalized by carnot's COP ) are plotted versus the thermal load Q applied to the cold end, for various speaker power.

  • PDF

An Experimental Study on the 2nd,3rd Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (밀폐관형과 개방관형 열음향 냉동기의 2차, 3차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;박영선
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.193-196
    • /
    • 2002
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In order to determine the optimum resonant tube length and the frequency, the open-tube-type(3$\lambda$/4) and close- tube - type (2$\lambda$/2) thermoacoustic refrigerator were constructed. In third harmonic, the temperature difference of 3$\lambda$/4 refrigerator was $53^{\circ}C$(resonator length :400mm). In second harmonic, the temperature difference of 2$\lambda$/2 refrigerator was $51^{\circ}C$(resonator length :400mm).

  • PDF

The construction and performance Investigation of 1/2 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant (헬륨을 냉매로 사용한 1/2파장 열음향 냉동기의 실험 및 성능평가)

  • Choi, Doo-Won;Kim, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.471-476
    • /
    • 2006
  • Thermoacoustic refrigerators are operated with acoustic power to pump heat. The acoustic standing wave displaces the gas In the channels of the stack while compressing and expanding. The thermal interaction between the osillating gas he surface of the stack generates an acoustic heat pumping. in this study, a thermoacoustic refrigerator is composed of a resonator of 4cm diameter, stack of plates, heat exchangers and cooling part. Length of the hot heat exchangers, the stack of plates and the cold heat exchanger are 9mm, 8mm and 6mm respectively. Using helium as a coolant at frequency of 516Hz, the cold-part temperature of exchanger fell to $-19.0^{\circ}C$ after 1hours.

  • PDF