Studies on the Correlation between Mechanical Properties and Ultrasonic Parameters of Aging 1Cr-1Mo-0.25V Steel

  • Seok Chang-Sung;Kim Jeong-Pyo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.487-495
    • /
    • 2005
  • Mechanical properties of in-service facilities are required to evaluate the integrity of power plants and chemical plants. Non-destructive technique can be used to evaluate the mechanical properties. To investigate the mechanical properties using ultrasonic technique, the four classes of thermally aged specimens were prepared using an artificially accelerated aging method. Ultrasonic tests, tensile tests, fracture toughness tests, and hardness tests were performed for the specimens. Then the mechanical properties were compared with ultrasonic parameters such as attenuation and non-linear parameter. From the investigation, we confirm that the ultrasonic parameter can be used to evaluate the mechanical properties.

Effects of Ce on the Mechanical Alloying Behavior and Thermal Stability of Al-8wt.%Fe Powder (Al-8wt.%Fe 분말의 기계적 합금화 거동과 열적안정성에 미치는 Ce의 영향)

  • 오광진
    • Journal of Powder Materials
    • /
    • v.1 no.1
    • /
    • pp.4-14
    • /
    • 1994
  • The effects of Ce on the mechanical alloying behavior and the thermal stability of Al-8wt.%Fe were investigated. The steady states of Al-8wt.%Fe and Al-8wt.%Fe-4wt.%Ce powders with 1.5 wt.% stearic acid as a process control agent were reached after mechanical alloying for 1000 minuties and 1300 minuties respectively at the conditions of the impeller revolving velocity of 300 rpm and the ball to powder input ratio of 50 : 1. The hardness of Al-8wt.%Fe specimen hot extruded and isothermally aged at various temperatures for up to 1000 hours decreased rapidly at 50$0^{\circ}C$ and its high temperature ultimate tensile strength began to decrease at 40$0^{\circ}C$ with increasing aging time. The decrease in the hardness and ultimate tensile strength of the specimen were reduced substantially by addition of Ce. It was thought to be due to the formation of thermally stable A14Ce and All3Fe3Ce intermetallic compounds.

  • PDF

A Study on the Evaluation of Material Degradation of 1Cr-1Mo-0.25V Steel using Ultrasonic Techniques (초음파법을 이용한 1Cr-1Mo-0.25V강의 열화도 평가에 관한 연구)

  • Kim, Jeong-Pyo;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.78-83
    • /
    • 2001
  • It's required mechanical properties of in-service facilities to maintain safety operation in power plants as well as chemical plants. In this study the four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method at $630^{\circ}C$. Ultrasonic tests, tensile tests, $K_{IC}$ tests and hardness tests were performed in order to evaluate the degree of degradation of the material. The mechanical properties were decreased as degraded, but the attenuation coefficient and the harmonic generation level of a ultrasonic signal were increased. Expecially the nonlinear parameter of the signal is sensitive and will be a good parameter to evaluate the material degradation.

  • PDF

The Evaluation of Ductile-Brittle Transition of Fracture Toughness by Material Degradation (재료열화에 따른 파괴인성치의 연성-취성 천이거동 평가)

  • Kim, Sang-Pil;Kim, Hyung-Ick;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.579-584
    • /
    • 2001
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life, and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sired specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

  • PDF

Long-Term Aging Diagnosis of Rotor Steel Using Acoustic Nonlinearity

  • Kim, Chung-Seok;Park, Ik-Keun;Jhang, Kyung-Young;Hyun, Chang-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.642-649
    • /
    • 2011
  • The long-term aging of ferritic 2.25CrMo steel was characterized using the acoustic nonlinear effect in order to apply to diagnose the degradation behavior of structural materials. We measured the acoustic nonlinearity parameter for each thermally aged specimen by the higher harmonic-generation technique. The acoustic nonlinearity parameter increased with aging time due to equilibrium M6C carbide precipitation, and has a favorable linear relation with Rockwell hardness. This study suggests that acoustic nonlinearity testing may be applicable to diagnostics on strength degradation in rotor steels.

An experimental study on the unequal thickness joint using FSW with $4mm^{t}$ and $6mm^{t}$ Al 6061 T6 plates (Al 6061 T6 합금의 이두께 마찰교반 용접에 관한 연구)

  • Ryu, Deok-Hui;Kim, Jae-Seong;Jin, Hyeong-Guk;Lee, Jae-Hun;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.223-225
    • /
    • 2005
  • In order to demonstrate the friction stir weldability of the Al 6061 T-6 unequal thickness joint and determine optimum welding parameters, the relations between welding parameters and properties of the joints have been studied in this paper. The experimental results showed that the tensile properties of the joints are affected by the welding heat inputs and tool shape. In this study, the maximum ultimate strength of the as-welded joint is equivalent to 78% and 18hour aged joint is equivalent to 93% that of the base metal. Though the voids-free joints are fractured at the thermally affected zone on the advancing side, the fracture occurs at the weld center when the void defects exist in the joints.

  • PDF

Insulation Breakdown Frequency Properties of PAI Enamelled Rectangular Coils According to Thermal Deterioration Temperature Variation (열적 열화 온도 변화에 따른 PAI 에나멜 각형코일의 절연 파괴 주파수 특성)

  • Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.829-834
    • /
    • 2016
  • Coil specimens were prepared by continuous coating on a copper wire with flexible PAI (polyamideimide) and PAI/nanosilica (5 wt%) varnish and thermally aged at 150, 200 and $250^{\circ}C$ for 5, 10 and 15 days, respectively. AC insulation breakdown voltage was investigated under inverter surge condition at 60 Hz and 1,000 Hz and insulation breakdown voltage decreased with increasing aging temperature and aging time at each 60 and 1,000 Hz.

Thermal Aging Behaviors of Weather Resistant Rubber Composites of EPDM, IIR, and BIIR (EPDM, IIR, 그리고 BIIR 내후성 고무 복합체의 열노화 거동)

  • Choi, Sung-Seen;Kim, Jong-Chul
    • Elastomers and Composites
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2012
  • EPDM, IIR, and BIIR composites were thermally aged and the crosslink density changes were investigated. Crosslink densities of the EPDM composite increased with increasing the aging time and temperature, whereas those of IIR and BIIR composites for long-term aging at high temperatures tended to decrease. Activation energies for the crosslink density changes of the EPDM composite were higher than those of the BIIR one. The experimental results were explained with the number of allylic hydrogens, activation of the zinc complex, the steric hindrance effect, and oxidation of rubber chain.

Evaluation of Microstructure and Mechanical Property of Inconel 600 Degraded under High Temperature (고온 열화된 Inconel 600강의 미세조직 및 기계적 특성 평가)

  • Jung, Kwang-Hu;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.492-497
    • /
    • 2017
  • In this study, we investigated the effect of thermal aging on mechanical characteristics of Inconel 600 nickel-based alloy. The thermal aging was conducted up to 1000 hours at an atmosphere of $650^{\circ}C$. The microstructure of thermally aged specimens was investigated by an optical microscope (OM), scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). In addition, tensile test (strain rate: 2 mm/min) and micro Vickers hardness test were conducted to evaluate mechanical properties with time. As a result of the experiment, Cr-rich carbide continuously precipitated during thermal aging, leading to the change of the mechanical characteristics and fracture mode. With the increase of aging time, tensile strength, yield strength, and hardness gradually decreased. The fracture mode changed from ductile to brittle with the increase of grain boundary carbide.

Fatigue Crack Growth Behavior of NR/EPDM Blend

  • Chung, Woo-Won;Chang, Young-Wook
    • Macromolecular Research
    • /
    • v.9 no.6
    • /
    • pp.319-326
    • /
    • 2001
  • Fatigue crack growth (FCG) behavior of natural rubber/ethylene-propylene-diene rubber (NR/EPDM) blend vulcanizates under dynamic tearing condition was investigated by using a fracture mechanics approach. It appeared that variation of crack growth rate with blend compositions was dependent on the level of imposed tearing energy G. At low tearing energy region, the FCG rates of the blend were lower as the EPDM content was increased, while at high tearing energy region, the trend was reversed. Over the measured range of tearing energy G, all blend compositions showed the lower crack growth rates compared to the average of properties of component elastomers. When the blends were thermally aged, the fatigue resistance of the blends was deteriorated in proportion to the concentration of EPDM phase. Fatigue crack growth behavior of the blends was supposed to be associated with the inhomogeneities of the crosslink structure of the blends arising from cure incompatibility of the EPDM and NR when they are sulphur cured.

  • PDF