• Title/Summary/Keyword: Thermal therapy

Search Result 209, Processing Time 0.028 seconds

Thermoelastic beam in modified couple stress thermoelasticity induced by laser pulse

  • Kumar, Rajneesh;Devi, Shaloo
    • Computers and Concrete
    • /
    • v.19 no.6
    • /
    • pp.701-710
    • /
    • 2017
  • In this study, the thermoelastic beam in modified couple stress theory due to laser source and heat flux is investigated. The beam are heated by a non-Guassian laser pulse and heat flux. The Euler Bernoulli beam theory and the Laplace transform technique are applied to solve the basic equations for coupled thermoelasticity. The simply-supported and isothermal boundary conditions are assumed for both ends of the beam. A general algorithm of the inverse Laplace transform is developed. The analytical results have been numerically analyzed with the help of MATLAB software. The numerically computed results for lateral deflection, thermal moment and axial stress due to laser source and heat flux have been presented graphically. Some comparisons have been shown in figures to estimate the effects of couple stress on the physical quantities. A particular case of interest is also derived. The study of laser-pulse find many applications in the field of biomedical, imaging processing, material processing and medicine with regard to diagnostics and therapy.

Temperature Rise During Laser Photodynamic Therapy in a Mouse Tumor Model

  • Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.17-22
    • /
    • 1993
  • Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided intro two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weights). The other group received no Photofrin E Mice from both groups were irradiated for approximately 15 minutes at 100,300, or $500{\;}mW/\textrm{cm}^2$ with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photofrin II increased surface temperature by at least 40% and the temperature rise due to $300{\;}mW/\textrm{cm}^2$ irradiation exceeded values for hyperthermia. Lights and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise.

  • PDF

A Study on the Variations of the Body Trunk Temperature by the Drug-Pad Moxibustion Method (약패드 뜸 방식을 이용한 체간온도변화에 대한 연구)

  • Yoon Dong-Eop;Jo Bong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.8
    • /
    • pp.386-396
    • /
    • 2006
  • We implemented the Drug-Pad Moxibustion Method in order to improve the conventional moxibustion therapy. This method is aimed to eliminate burning wounds and smoke, which are the defects of conventional moxibustion therapy. And we performed to verify the efficiency by comparing the Drug-Pad Moxibustion Method with the conventional Indirect Moxibustion Therapy. We measured the body heat and the lasting time of blood circulation improvement using thermography. The moxibustion therapy has two kinds of effects: The formers are pharmacological effects of the Moxa's vasodilators and antioxidants. The latters are thermal effects which cause improvement of the blood circulation. To remove the demerits without omission of above therapeutic effects, we extracted the vasodilators and antioxidant compounds from the Moxa-$CH_2Cl_2$ fraction Moxa-EtOAc and composed the moxibustion kit with $(Ba_{0.8}\;Sr_{0.2})_{0.996}\;Y_{0.004}\;TiO_2+0.5_{WT}\;SiO_2%$ Positive Temperature Coefficients Thermistor. The experimental demonstrations have been made by the stimulating the spot which is CV4(Kwan-Won), CV8(Shin-Guel), CV12(Jung-Wan) acupuncture points of the conception vessel meridian(CV). And stimulating time was one hour. We divided the subjects into 5 groups such as no stimulation group, conventional Indirect Moxibustion group, only Drug-Pad stimulation group, only heat stimulation group, and Drug-Pad Moxibustion group. In the different cases, we have measured the body heat in pre-stimulation, just after stimulation, 2 hours after, and 4 hours after. The body heats of the group who were stimulated by the Drug-Pad Moxibustion Method were increased by over the $2^{\circ}C$. And the body heats of the group who were stimulated by the Indirect Moxibustion Method were increased by average the $1^{\circ}C$. We have evaluated that the Drug-Pad Moxibustion Method is improvement on the conventional Indirect Moxibustion Method by the heat-increasing rate is 200% and the lasting time is 150% with the body heat of the abdominal region. In the conclusions, We have implemented the Drug-Pad Moxibustion Method and evaluated the efficiency of the Drug-Pad Moxibustion Method comparing with the conventional Indirect Moxibustion Method.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

The Effect of Titaniuml Surface Treatment on Osteoblast-Like Cell Attachment and Proliferation (Titanium 표면처리 방법이 Osteoblast-like Cells의부착 및 증식에 미치는 영향)

  • Kim, Do-Yung;Seol, Yang-Jo;Rhyu, In-Cheul;Hahm, Byung-Do;Chung, Chong-Pyoung;Choi, Sang-Mook;Kim, Woo-Jin;Baik, Hong-Koo;Heo, Seong-Joo;Han, Chong-Hyun;Kim, Myung-Ho;Choi, Yong-Chang;Chun, Heoung-Jae;Kwon, Soo-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.491-504
    • /
    • 2000
  • In clinical therapy, the current goal of dental implants is to enhance quantity and quality of osseointegration. Surface roughness and oxide structure are considered to influence the behavior of adherent cells. The purpose of this study is to evaluate the effect of different surface treatment on cellular response. The attachment and proliferation of osteoblast-like cell on sandblasted, sandblasted and etched, thermal oxidated surfaces have been compared. Sandblasting was done with $Al_2O_3$ particles(grain size of $50{\mu}m$), etching was processed with $NH_4OH$ : $H_2O_2$ : $H_2O(1:1:5)$ at $90^{\circ}C$ for 1 minute. Thermal oxidation was followed sandblasting and etching at $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$ for 2 hours. Measurement of surface roughness after the different treatment did not show any differences of Ra value between terated surfaces. Cell attachment and proliferation were increased during experiment period, but no difference was observed. SEM evaluation revealed a similar pattern of osteoblast-like cells, well attached with dendritic extension and producing numerous matrix vesicles on cell surface. The results of this study showed that oxide layer alteration by thermal oxidation did not affect the attachment and proliferation of osteoblast-like cells. This suggests the possibility that the cellular responses are further influenced by surface roughness than titaniun oxide structure.

  • PDF

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

Alteration of Forearm Local Temperature and Median Nerve Conduction Velocity by Therapeutic Ultrasound in Healthy Adult Subjects (초음파에 의한 전완 국소 온도와 정중 운동 신경전도 속도의 변화)

  • Jeon, Cha-Sun;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

  • PDF

A Clinical Case Study of Common Peroneal Nerve Palsy(Foot Drop) Following Entrapment Neuropathy (압박성 신경병증에 의한 족하수(足下垂) 환자(患者) 1례(例)에 대한 임상적(臨床的) 고찰(考察))

  • Shin, Jeong-Cheol;Lee, Dong-Hyun;Wei, Tung-Shuen;Kim, Seon-Jong;Choe, Won-Hwak;Ryu, Chung-Ryul;Yun, Yeo-Choong;Cho, Myung-Rae;Che, Wu-Suk;Na, Gun-Ho
    • Journal of Acupuncture Research
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2005
  • Objectives : The Purpose of this study is to report in patient with common peroneal nerve palsy, who improved by oriental medical treatament. Methods : We Checked the temperature of a leg by Digital Infrared Thermal Imaging(DITI) at intervals of 10 days, angle of active dorsiflexion and range of active motion for estimating the improvement of symptoms. We used the Visual Analogue Scale(VAS) for estimating the degree of pain, too. Results : After 4 weeks treatment, the movement and power of ankle joint improved to nearly normal range. The degree of active dorsiflexion of the ankle increased from $-40^{\circ}\;to\;15^{\circ}$ and range of active motion increased from Gr III to Gr I. The difference of temperature between the both legs decreased remarkably. Conclusion : In this case we experienced improvement of symptoms by conservative oriental medical therapy, e.g acupuncture stimulation, herbal medication, physical therapy. It should be needed further investigation on common peroneal nerve palsy and its symptoms in order to set up a reasonable standard about a surgical operation.

  • PDF

Laryngeal Inhalation Injury (흡인성 화상에 의한 후두 손상)

  • 조정일;김영모;임정혁;김용재;이철우;이명택
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2001
  • Background and Objectives : A burn injury to the glottis differs from a burn injury to the trachea, bronchi, and lung parenchyma, in that thermal injury does not occur to any significant degree below the level of the larynx, due to the effective cooling of air by the upper airway and to reflex closure of the vocal cords from a blast of hot air. Therefore, the laryngeal inhalation injury give rise to airway problem and voice change. The objectives of this study is to assess management of laryngeal inhalation injury and voice change after management. Materials and Methods : Voice choses and laryngeal injuries of eight laryngeal inhalation patients were analyzed through questionnaire, voice dynamic laboratory, and laryngeal stroboscopy. Operative management was performed to five patients for airway patiency and vocal cord movement on laryngeal pathology ind voice therapy was performed to all patients. One-year after, voice changes and laryngeal injuries were reanalyzed with same methods. Results : Vocal breathiness, decreased voice intensity, reduced voice range, and easy fatigability were major complaints of laryngeal inhalation patients. Glottic stenosis were developed to five of eight patients, and vocal cord atrophy, bowing were developed to others. Vocal cord mucosal waves were significantly decreased in all patients. Jitter(%), Shimmer(dB) were increased and Maximal phonation time(MPT) was decreased. One-year after, subjective voice changes and objective voice parameters were improved. And vocal cord mucosal waves were recovered in all patients. Conclusions : Subjective voice quality and objective voice parameters were improved after operative management for laryngeal pathology and voice therapy. And we observed recovery of vocal fold mucosal waves by laryngeal stroboscopy. We think that early preventable tracheotomy is necessary to reduce the laryngeal contact injury in laryngeal inhalation patients.

  • PDF

Effect of the low level light irradiation to NTacSam:SD tissue cell culture (NTacSam:SD의 조직세포 배양에 저출력 광원의 효과)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Park, No-Bong;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.423-423
    • /
    • 2009
  • Currently, lasers are one of the most popular light sources in use for medical treatment. Many studies on low power lasers are being done in cell culture or through animal tests and most report different findings, making it difficult to verify their true effects. There are shifts in trends of studies from laser and LED that are expensive and generate heat problem to LED that are economically effective and safe. Its near infrared rays can penetrate deep into skin or muscle, up to 23 cm, without causing thermal damage or impairing neighboring tissues. This study verified the performance and effectiveness of an LED irradiator that was designed to emit similar wavelengths to that of a laser and thus could be used instead of a low level laser therapy in experiments on animals. And then, each experiment was performed to irradiation group and non-irradiation group for NTacSam:SD tissue cells. MIT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of NTacSam:SD tissue cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.

  • PDF