• 제목/요약/키워드: Thermal switch

검색결과 79건 처리시간 0.305초

2단 냉동기의 냉각시간 단축을 위한 기체-간극 열스위치 설계 (Design of gas-gap thermal switch for reducing cooldown time of 2-stage cryocooler)

  • 김형진;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2000
  • A preliminary design of gas-gp thermal switch is presented to reduce the cooldown time of superconducting system conduction-cooled by a two-stage refrigerator without liquid cryogens. The switch connects thermally the first and the second stages (ON) to take advantage of the larger refrigeration capacity at the first stage during the beginning period. After the cryogenic temperature is reached, the switch should isolate thermally the two stages (OFF) in order to reduce the heat leak to the cold end. In this paper, a new concept for the performance index is introduced to evaluate the reduction of the cooldown time and the increase of the cooling load at the same time. In addition, the design of a gas-gap switch is discussed as a closed container of several staggered concentric tubes filled with gas, which is frozen at low temperatures for the shut-off of heat without any mechanical actuation. Some of the detailed features in the design is quantitative investigated by the gas convection model in the continuum or the rarefied gas region.

  • PDF

출력 스위치의 열화를 고려한 주파수 가변 구동 방식의 전자식 안정기 설계 (Design of Electronic Ballasts applied with Variable Frequency Driving Technique with regard for Thermal Degradation of Output Switches)

  • 오성근;최명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.157-161
    • /
    • 2000
  • The electronic ballasts for low pressure discharge lamps are produced and commercialized. However, the electronic ballasts for high pressure lamps are now in progress because of poor reliability and high cost. The major case of troubles with electronic ballasts are thermal destruction of semiconductor output switches due to non ideal i-v characteristics of switch. The loss converts to heat and rises the temperature of switch and it increases proportionally to switching frequency and value of current and voltage. This study shows the variable frequency ballasts which can suppress the heating of switches efficiently. It is used for the limitation the switch current and the rising temperature of switch by impedance variation of lamp inductor. As a result, initial warm-up time of the proposed ballasts was faster than that of magnetic ballasts about 90 msec. Power factor of tested ballasts follow as ; input and output average of magnetic ballasts are 93 [%] and 86 [%], respectively, And proposed ballasts are 97 [%] and 99 [%], respectively.

  • PDF

3차원 열특성해석을 통한 히터트리거 고온초전도 스위치의 설계 (Design of Heater-trigger HTS Switch through 3-Dimensional Thermal Characteristic Analysis)

  • 안민철;윤용수;김호민;김태중;김영식;배덕권;이상진;한태수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.714-716
    • /
    • 2001
  • This paper is about the characteristic analysis of a heater-trigger HTS switch. It is composed of a BSCCO tape wire and a heater as a thermal quench source. To minimize the heat flow to the liquid nitrigen, the epoxy was used around them. The heater-trigger switch operates in the process that the HTS tape is thermally quenched by the current flowing through the heater. Since the switch works in coolant, it needs to be designed by the accurate thermal characteristic analysis. Here, we focus on FEM for it.

  • PDF

The Coupled Electro-Thermal Field Analysis for Predicting Over-Current Protector Behavior

  • Bae, Jae-Nam;Lee, Sung-Gu;Han, Jung-Ho;Chung, Hae-Yang;Lee, Ju
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.43-48
    • /
    • 2008
  • The characteristics of heat transfer of the bimetal disc for over-current protection device is specified. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the thermal characteristics, temperature distribution when bimetal acts as a switch is calculated. As usual, heat source is applied to the bimetal and electric current is heat source in the over-current protection switch. In this paper, thermal distribution are obtained by solving a coupled electro-thermal field with 3D finite element method.

도시형 자기부상열차 3방향 분기기 개발현황 및 시험결과 (Development Status and Test Results of the 3 way Switch for the Urban Maglev)

  • 이종민;한형석;김창현;신현재;서성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1742-1749
    • /
    • 2011
  • The 3 way segmented Maglev switch is developed for the urban Maglev vehicle, which is scheduled to debut at the middle of 2013 in Incheon International Airport. The 3 way switch is composed of 3 moving girders, 4 fixed girders, driving units, moving units, clamping units and articulated angle relieving equipment etc. In this paper, the measured results on the interaction between vehicle and switch are discussed. The measured results are following; First, continuous moving test and natural frequency for girder and levitation rail. Second, levitation and lateral air gap of the bogies running on the curved switch. Third, noise of moving mechanical parts of the 3 way segmented switch. Forth, thermal displacement of the girder due to temperature change. With over the measured results, more reliability and stability of the 3 way segmented switch are secured.

  • PDF

Coated conductor를 이용한 히터트리거 방식의 영구전류 스위치의 제작과 실험 (Fabrication and test of heater triggered persistent current switch using coated conductor tapes)

  • 김영재;양성은;박동근;조대호;안민철;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2039-2040
    • /
    • 2006
  • Persistent current switch (PCS) system in NMR, MRI, MAGLEV and SMES has many advantages, such as uniformity and durability of magnetic field and reducing a thermal loss, which enable many superconducting application to operate effectively. This paper deals with fabrication and test of heater trigger persistent current switch using coated conductor (CC) which has high n-index, critical current independency from external magnetic field and adaptable selectivity of stabilizer. PCS system consists of magnet power supply for energizing current to a magnet, heater, switch and magnet using coated conductor tape. Finite element method (FEM) is used to simulate thermal quench (switching) characteristic and design heater trigger. With FEM simulation, optimal length of heater is calculated by temperature and time analysis. Fabrication of PCS system and test of heater trigger characteristic were performed and compared with simulation result. This paper would be the foundation of researches of superconducting switching application.

  • PDF

반도체 광스위치 모듈의 제작 및 특성연구 (Fabrication of semiconductor optical switch module using laser welding technique)

  • 강승구
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.73-79
    • /
    • 1999
  • 1$\times$2, 1$\times$4 및 4$\times$4 LD-gate형 반도체 광스위치 모듈을 제작하였다. 스위치 소자와 광섬유와의 광결합을 위해서 테이퍼드 광섬유를 어레어로 제작하여 사용하였으며 30핀 버터플라이형 패키지로 완성하였다. 광 부푼 정렬 및 고정에서는 레이저 용접법 및 햄머링 공정을 이용하여 최초의 광정렬 값에서 평균 82%까지 복원하였다. 완성된 모듈에 대한 평가를 위해 전송 실험을 수행하였는데 1$\times$2 스위치 모듈이 삽입되었을 때 223-1의 단어길이를 갖는2.5Gbps 광신호에 대해서 전송패널티가 약0.5dB~2dB로 나타났으며, 광섬유의 분산특성에 의하여 발생하는 전송 패널티에 대해서는 50km 및 90km 광섬유에 대해서 각각 0.6dB 및 0.7dB의 작은 패널티가 발생하였다. 1$\times$4 및 4$\times$4 스위치 모듈을 이용한 전송특성 평가에서도 모두 -30dB 이하의 수신감도를 갖는 우수한 결과를 보였다.

  • PDF

자계 분포시 열유동 현상 분석을 통한 결합계 해석 (The coupling field analysis of a thermal transfer phenomenon by an magnetic field)

  • 손락원;장광용;배재남;김승주;최승길;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.862-863
    • /
    • 2007
  • In this article, we researched the characteristics of heat transfer of the bimetal for over-current protection device. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the heat transfer characteristics, by using a bimetal which has a single metal, we analyzed the temperature distribution when bimetal acts a switch. As usual, heat source is applied to the bimetal. But, in the over-current protection switch, the current become heat source. So, by using the current as source, we performed the magnetic analysis and thermal analysis together.

  • PDF