• 제목/요약/키워드: Thermal safety evaluation

검색결과 257건 처리시간 0.027초

안료제조시 중화공정의 열안정성 평가 (Evaluation of Thermal Stability in Neutralization Process of Pigment Plant)

  • 이근원;한인수;박상현
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.43-50
    • /
    • 2007
  • Lack of understanding of the process chemistry and thermodynamics are the major reasons that can is lead to thermal runaway reaction in the chemical reaction process. The evaluation of reaction factors and thermal behavior in neutralization process of pigment plant are described in this paper. The experiments were performed in the C 80 calorimeter, and Thermal Screening Unit($TS^{u}$). The aim of the study was to evaluate the results of thermal stability in terms of safety reliability to be practical applications. It suggested that we be proposed safe operating conditions and securities for accident prevention through this study.

비닐아세테이트 중합공정에서 원료물질의 열적 안정성 평가 (An Evaluation of Thermal Stability of Raw Materials in the Vinyl Acetate Polymerization Process)

  • 이근원;한인수;이정석
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.61-65
    • /
    • 2010
  • Most of the chemical reactions performed in the chemical industry are exothermic, meaning that thermal energy is released during the reaction. It is also important to understand the thermal hazards such as thermal stabilities and runaway reactions, which are governed by thermodynamics and reaction kinetics of the mixed materials. The paper was described the evaluation of thermal behavior caused by an exothermic batch process in manufacture of the vinyl acetate resin. The aim of the study was to evaluate the thermal stabilities of raw materials with operating conditions such as a reaction inhibitor, heating rate, reaction atmosphere and the mount of methanol charged in the vinyl acetate polymerization process. The experiments were performed in the differential scanning calorimeter(DSC), C 80 calorimeter, and thermal screening unit($TS^u$). It was suggested that we should provide the thermal characteristics for raw materials to present safe precautions with operating conditions in the vinyl acetate polymerization process.

시멘트 혼화제 제조시 에스테르화공정의 열 안정성 평가 (An Evaluation of Thermal Stability on Esterification Process in Manufacture of Concrete Mixture Agents)

  • 이근원;이정적;최이락;한인수
    • 한국안전학회지
    • /
    • 제24권4호
    • /
    • pp.40-46
    • /
    • 2009
  • The early identification of thermal hazards associated with a process such as the heats of reaction, exothermic decompositions, and the understanding of thermodynamics before any large scale operations are undertaken. The evaluation of reaction factors and thermal behavior on esterification process in manufacture of concrete mixture agents are described in the present paper. The experiments were performed in the differential scanning calorimetry(DSC), C 80 calorimeter, and thermal screening unit($TS^u$). The aim of the study was to evaluate the thermal stability of single material and mixture in esterification process. We provided the thermal data of chemical materials to present safe operating conditions through this study.

Multimax Reactor System을 이용한 안료제조시 중화공정의 열적위험성 평가 (Evaluation of Thermal Hazard in Neutralization Process of Pigment Plant by Multimax Reactor System)

  • 이근원;한민수
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.91-99
    • /
    • 2008
  • The identification of thermal hazards associated with a process such as heats of reaction and understanding of thermodynamics before any large scale operations are undertaken. The evaluation of thermal behavior with operating conditions such as a reaction temperature, stirrer speed and reactants concentration in neutralization process of pigment plant are described. The experiments were performed by a sort of calorimetry with multimax reactor system The aim of the study was to evaluate the results of heat of reaction in terms of safety reliability to be practical applications. It suggested that we be proposed safe operating conditions and securities for accident prevention on reactor explosion through this study.

Thermal Fluid Mixing Behavior during Medium Break LOCA in Evaluation of Pressurized Thermal Shock

  • Jung, Jae-Won;Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.635-640
    • /
    • 1998
  • Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. The applicability of RELAP5 code to analyze thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of Thermal stratification is investigated using Theofanous's empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing.

  • PDF

압력잠김 및 열고착 현상 발생가능 밸브의 선정 (Selection of Valves Susceptible to Pressure Locking and Thermal Binding)

  • 이성노;안진근;김석범
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.20-26
    • /
    • 2007
  • Some gate valves are susceptible to pressure locking and thermal binding which prevent the safety function. The safety related gate valves susceptible to pressure locking and thermal binding shall be identified and taken preventive actions to ensure the safety function. The identification of the gate valves susceptible to pressure locking and thermal binding needs the evaluation of system design, valve and piping arrangement, test requirements, and operating conditions. Application of preventive methods should consider the system safety function, applicability, effectiveness, interface with system design, and cost. The selection procedure of valves susceptible to pressure locking and thermal binding can be effectively used in industry including nuclear power plants. In order to prevent the pressure locking, the hole can be drilled through the one disc of upstream side or down stream and the external equalizing line can be installed from bonnet to downstream or upstream. The double disc parallel seat valve type can be used instead of flexible wedge gate valve to prevent the thermal binding. The identification of gate valves susceptible to pressure locking and thermal binding, and preventive actions will meet the regulatory requirements and enhance the availability and safety of plants.

Thermal Inactivation of Sodium-Habituated Staphylococcus aureus in Ready-to-Heat Sauces

  • Park, Ahreum;Lee, Jinhee;Jeong, Sook-Jin;Hwang, In-Gyun;Lee, Soon-Ho;Cho, Joon-Il;Yoon, Yohan
    • 한국축산식품학회지
    • /
    • 제32권6호
    • /
    • pp.713-717
    • /
    • 2012
  • The objective of this study was to evaluate the effect of sodium habituation on thermal resistance of Staphylococcus aureus in various ready-to-heat (RTH) sauces. The strain mixture of S. aureus strains KACC10768, KACC10778, KACC11596, KACC13236 and NCCP10862 was habituated up to 9% of NaCl. The inocula of NaCl-habituated and non-habituated S. aureus were inoculated in 5 g portions of pork cutlet, meat and Carbonara sauces at 7 Log CFU/g, and the samples were vortexed vigorously. The inoculated samples were then exposed to 60 and $70^{\circ}C$ in a water-bath, and survivals of total bacteria and S. aureus were enumerated on tryptic soy agar and mannitol salt agar, respectively, every 30 min for 120 min. At 60oC, the cell counts of total bacteria and the significant difference in survivals between sodium-habituated and non-habituated S. aureus were observed only in the Carbonara sauce; the tailing effect, which is the period of no reduction of bacterial cell counts, was observed in pork cutlet, meat and Carbonara sauces subjected to $60^{\circ}C$. At $70^{\circ}C$, total bacterial populations and sodium-habituated and non-habituated S. aureus cell counts in meat and Carbonara sauce also significantly decreased (p<0.05) after 30 min of heat treatment, followed by the obvious tailing effect. Sodium-habituated S. aureus cell counts in meat and Carbonara sauces were higher (p<0.05) than those of non-habituated S. aureus at $70^{\circ}C$. The results indicate that sodium habituation of S. aureus cells may increase the thermal resistance of the pathogen in RTH sauces; moreover, heating RTH sauces for a short time before serving may not sufficiently decrease the cell counts of S. aureus, particularly for sodium-habituated strain.

Investigation of the various properties of several candidate additives as buffer materials

  • Gi-Jun Lee;Seok Yoon;Taehyun Kim;Seeun Chang
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1191-1198
    • /
    • 2023
  • Bentonite buffer material is a critical component in an engineered barrier system (EBS) for disposing high-level radioactive waste (HLW). The bentonite buffer material protects the disposal canister from groundwater penetration and releases decay heat to the surrounding rock mass; thus, it should possess high thermal conductivity, low hydraulic conductivity, and moderate swelling pressure to safely dispose the HLWs. Bentonite clay is a suitable buffer material because it satisfies the safety criteria. Several additives have been suggested as mixtures with bentonite to increase the thermal-hydraulic-mechanical-chemical (THMC) properties of bentonite buffer materials. Therefore, this study investigated the geotechnical, mineralogical, and THMC properties of several candidate additives such as sand, graphite, granite, and SiC powders. Datasets obtained in this study can be used to select adequate additives to improve the THMC properties of the buffer material.

LBLOCA AND DVI LINE BREAK TESTS WITH THE ATLAS INTEGRAL FACILITY

  • Baek, Won-Pil;Kim, Yeon-Sik;Choi, Ki-Yong
    • Nuclear Engineering and Technology
    • /
    • 제41권6호
    • /
    • pp.775-784
    • /
    • 2009
  • This paper summarizes the tests performed in the ATLAS facility during its first two years of operation (2007${\sim}$2008). Two categories of tests have been performed successfully: (a) the reflood phase of the large-break loss-of-coolant accidents in a cold leg, and (b) the breaks in one of four direct vessel injection lines. Those tests contributed to understanding the unique thermal-hydraulic behavior, resolving the safety-related concerns and providing an evaluation of the safety analysis codes and methodology for the advanced pressurized water reactor, APR1400. Several important and interesting phenomena have been observed during the tests. In most cases, the ATLAS shows reasonable accident characteristics and conservative results compared with those predicted by one-dimensional safety analysis codes. A wide variety of small-break LOCA tests will be performed in 2009.