• Title/Summary/Keyword: Thermal rise

Search Result 747, Processing Time 0.035 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Study of Oil Palm Biomass Resources (Part 5) - Torrefaction of Pellets Made from Oil Palm Biomass - (오일팜 바이오매스의 자원화 연구 V - 오일팜 바이오매스 펠릿의 반탄화 연구 -)

  • Lee, Ji-Young;Kim, Chul-Hwan;Sung, Yong Joo;Nam, Hye-Gyeong;Park, Hyeong-Hun;Kwon, Sol;Park, Dong-Hun;Joo, Su-Yeon;Yim, Hyun-Tek;Lee, Min-Seok;Kim, Se-Bin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.2
    • /
    • pp.34-45
    • /
    • 2016
  • Global warming and climate change have been caused by combustion of fossil fuels. The greenhouse gases contributed to the rise of temperature between $0.6^{\circ}C$ and $0.9^{\circ}C$ over the past century. Presently, fossil fuels account for about 88% of the commercial energy sources used. In developing countries, fossil fuels are a very attractive energy source because they are available and relatively inexpensive. The environmental problems with fossil fuels have been aggravating stress from already existing factors including acid deposition, urban air pollution, and climate change. In order to control greenhouse gas emissions, particularly CO2, fossil fuels must be replaced by eco-friendly fuels such as biomass. The use of renewable energy sources is becoming increasingly necessary. The biomass resources are the most common form of renewable energy. The conversion of biomass into energy can be achieved in a number of ways. The most common form of converted biomass is pellet fuels as biofuels made from compressed organic matter or biomass. Pellets from lignocellulosic biomass has compared to conventional fuels with a relatively low bulk and energy density and a low degree of homogeneity. Thermal pretreatment technology like torrefaction is applied to improve fuel efficiency of lignocellulosic biomass, i.e., less moisture and oxygen in the product, preferrable grinding properties, storage properties, etc.. During torrefacton, lignocelluosic biomass such as palm kernell shell (PKS) and empty fruit bunch (EFB) was roasted under an oxygen-depleted enviroment at temperature between 200 and $300^{\circ}C$. Low degree of thermal treatment led to the removal of moisture and low molecular volatile matters with low O/C and H/C elemental ratios. The mechanical characteristics of torrefied biomass have also been altered to a brittle and partly hydrophobic materials. Unfortunately, it was much harder to form pellets from torrefied PKS and EFB due to thermal degradation of lignin as a natural binder during torrefaction compared to non-torrefied ones. For easy pelletization of biomass with torrefaction, pellets from PKS and EFB were manufactured before torrefaction, and thereafter they were torrefied at different temperature. Even after torrefaction of pellets from PKS and EFB, their appearance was well preserved with better fuel efficiency than non-torrefied ones. The physical properties of the torrefied pellets largely depended on the torrefaction condition such as reaction time and reaction temperature. Temperature over $250^{\circ}C$ during torrefaction gave a significant impact on the fuel properties of the pellets. In particular, torrefied EFB pellets displayed much faster development of the fuel properties than did torrefied PKS pellets. During torrefaction, extensive carbonization with the increase of fixed carbons, the behavior of thermal degradation of torrefied biomass became significantly different according to the increase of torrefaction temperature. In conclusion, pelletization of PKS and EFB before torrefaction made it much easier to proceed with torrefaction of pellets from PKS and EFB, leading to excellent eco-friendly fuels.

Management Strategies of Ventilation Paths for Improving Thermal Environment - A Case Study of Gimhae, South Korea - (도시 열환경 개선을 위한 바람길 관리 전략 - 김해시를 사례로 -)

  • EUM, Jeong-Hee;SON, Jeong-Min;SEO, Kyeong-Ho;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.1
    • /
    • pp.115-127
    • /
    • 2018
  • This study aims to propose management strategies of ventilation paths for improving urban thermal environments. For this purpose, Gimhae-si in Gyeongsangnamdo was selected as a study area. We analyzed hot spots and cool spots in Gimhae by using Landsat 8 satellite image data and spatial statistical analysis, and finally derived the vulnerable areas to thermal environment. In addition, the characteristics of ventilation paths including wind direction and wind speed were analyzed by using data of the wind resource map provided by Korea Meteorological Administration. As a result, it was found that a lot of hot spots were similar to those with weak wind such as Jinyoung-eup, Jillye-myeon, Juchon-myeon and the downtown area. Based on the analysis, management strategies of ventilation paths in Gimhye were presented as follows. Jinyoung-eup and Jillye-myeon with hot spot areas and week wind areas have a strong possibility that hot spot areas will be extended and strengthened, because industrial areas are being built. Hence, climate-friendly urban and architectural plans considering ventilation paths is required in these areas. In Juchon-myeon, where industrial complexes and agricultural complexes are located, climate-friendly plans are also required because high-rise apartment complexes and an urban development zone are planned, which may induce worse thermal environment in the future. It is expected that a planning of securing and enlarging ventilation paths will be established for climate-friendly urban management. and further the results will be utilized in urban renewal and environmental planning as well as urban basic plans. In addition, we expect that the results can be applied as basic data for climate change adaptation plan and the evaluation system for climate-friendly urban development of Gimhye.

Thermal and Uplift Histories of the Jurassic Granite Batholith in Southern Jeonju: Fission-track Thermochronological Analyses (전주 남부지역 쥬라기 화강암질 저반체의 지열사와 융기사: 피션트랙 열연대학적 해석)

  • Shin, Seong-Cheon
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.389-410
    • /
    • 2016
  • Wide ranges of fission-track (FT) ages were obtained from the Jurassic granite batholith in Jeonju-Gimje-Jeongeup area, southwestern Okcheon Belt: sphene=158~70 Ma; zircon=127~71 Ma; apatite=72~46 Ma. Thermochronological analyses based on undisturbed primary cooling and reset or partially-reduced FT ages, and some track-length data reveal complicated thermal histories of the granite. The overall cooling of the batholith is characterized by a relatively rapid earlier-cooling (${\sim}20^{\circ}/Ma$) to $300^{\circ}C$ isotherm since its crystallization and a very slow later-cooling ($2.0{\sim}1.5^{\circ}/Ma$) through the $300^{\circ}C-200^{\circ}C-100^{\circ}C$ isotherms to the present surface temperature. It is indicated that the large part of Jurassic granitic body experienced different level of elevated temperatures at least above $170^{\circ}C$ (maximum>$330^{\circ}C$) by a series of igneous activities in late Cretaceous. Consistent FT zircon ages from duplicate measurements for two sites of later igneous bodies define their formation ages: e.g., quartz porphyry=$73{\pm}3Ma$; diorite=$73{\pm}2Ma$; rhyolite=$72{\pm}3Ma$; feldspar porphyry=$78{\pm}4Ma$ (total weighted average=$73{\pm}3Ma$). Intrusions of these later igneous bodies and pegmatitic dyke swarms might play important roles in later thermal rise over the study area including hot-spring districts (e.g., Hwasim, Jukrim, Mogyokri, Hoebong etc.). On the basis of an assumption that the latercooling of granite batholith was essentially controlled by the denudation of overlying crust, the uplift since early Cretaceous was very slow with a mean rate of ~0.05 mm/year (i.e., ~50 m/Ma). Estimates of total uplifts since 100 Ma, 70 Ma and 40 Ma to present-day are ~5 km, ~3.5 km and ~2 km, respectively. The consistent values of total uplifts from different locations may suggest a regional plateau uplift with a uniform rate over the whole granitic body.

Mock-up Test of Temperature Crack Reduction Method Application by Setting Time Control of Mat Foundation Mass Concrete (응결시간조정에 의한 매트기초 매스 콘크리트의 온도균열저감 공법적용의 Mock-up Test)

  • Han, Cheon-Goo;Lee, Jae-Sam;Noh, Sang-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.55-61
    • /
    • 2009
  • Recently, the number of high-rise buildings being built in Korea by major construction companies for residential and commercial use has been increasing. When constructing a high-rise building, it is necessary to apply massive amounts of concrete to form a mat foundation that can withstand the huge load of the upper structure. However, it is of increasing concern that due to limitations in terms of the amount of placing equipment, available job-sites and systems for mass concrete placement in the construction field, it is not always possible to place a great quantity of concrete simultaneously in a large-scale mat foundation, and for this reason consistency between placement lift cannot be secured. In addition, a mat foundation Is likely to crack due to the stress caused by differences inhydration heat generation time. To derive a solution for these problems, this study provides test results of a hydration heat crack reduction method by applying placement lift change and setting time control with a super retarding agent for mass concrete in a large-scale mat foundation. Mock-up specimens with different mixtures and placement liftswere prepared at the job-site of a newly-constructed high-rise building. The test results show that slump flow of concrete before and after adding the super retarding agent somewhat Increases as the target retarding time gets longer, while the air content shows no great difference. The setting time was observed to be retarded as the target retarding time gets longer. As the target retarding time gets longer, compressive strength appears to be decreased at an early stage, but as time goes by, compressive strength gets higher, and the compressive strength at 28 days becomes equal or higher to that of plain concrete without a super retarding agent. For the effect of placement lift change and super retarding agent on the reduction of hydration heat, the application of 2 and 4 placement lifts and a super retarding agent makes it possible to secure consistency and reduce temperature difference between placement lifts, while also extending the time to reach peak temperature. This implies that the possibility of thermal crack induced by hydration heat is reduced. The best results are shown in the case of applying 4 placement lifts.

Metamorphism of the amphibolites in the Hwanggangri area, the northeastern region of Ogcheon metamorphic belt, Korea (옥천변성대 북동부 황강리 지역내 앰피볼라이트의 변성작용)

  • 유영복;김형식;권용완;박종길
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.57-81
    • /
    • 2001
  • In the amphibolites of the Hwanggangri area, three metamorphic zones are established like hornblende-actinolite zone (H-AZ), hornblende zone (HZ) and diopside zone (DZ) by the main mineral assemblages. Hornblende zone and hornblende-actinolite zone develope away from the diopside zone that experienced the highest thermal effect. Thus, this pattern identifies the decreasing metamorphic grade of the contact metamorphism with increasing distance from the granitic pluton. The mineral assemblages of this rock are classified into six representative groups such as $\circled1$ actinolite+plagioclase+chlorite, $\circled2$ actinolite+hornblende+plagioclase+chlorite$\pm$epidote$\pm$biotite, $\circled3$ actinolite+hornblende+plagioclass$\pm$biotite$\pm$epidote, $\circled4$ hornblende+plagioclase$\pm$biotite$\pm$chlorite, $\circled5$ hornblende+plagioclase+diopside+actinolite$\pm$epidote$\pm$chlorite, $\circled6$hornblende+plagioclase+diopside$\pm$biotite$\pm$epidote. Two metamorphic events m recognized in the amphibolites of the study area that the first metamorphism is the regional metamorphism dominantly occurred in the whole Ogcheon metamorphic belt and it gave rise to the growth of actinolite at the core or center of the amphibole grains of coarse and medium size. Its metamorphic grade ranges from the greenschist facies to epidote-amphibolite facies. The second metamorphism overlapped is the contact metamorphism caused by the adjacent granitic pluton, and its metamorphic grade is thought to reach to the low pressure part of upper amphibolite facies. According to the calculation by TWEEQU thermobarometry and amphibole-plagioclase thermometry, the metamorphic temperature of initial regional metamorphism is $439-537^{\circ}C$ under pressure of 4.6-7.3 kb and its peak temperature and pressure are considered to reach to the range of 492-537 and 5.2-7.3 kb. And the temperature range of contact metamorphism occurred by intrusion of cretaceous granitic body, is $588-739^{\circ}C$ under pressure of 2.6-5.2 kb and its peak temperature and pressure are estimated as having the range of $697-739^{\circ}C$ and 3.8-5.2 kb that this amphibolites are estimated to pass through the metamorphic evolution of both the rise of temperature and the drop of pressure.

  • PDF

Study on Control of Thermal Environmental Factors for Improvement of Productivity of Laying Hens in Summer (여름철 산란계사 내 열환경인자 중 제어요소에 관한 연구)

  • Kim, Seong-Wan;Lee, Tae-Hoon;Cha, Gwang-Jun;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.53 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • This study carried out to determine control factors for the improvement of productivity of laying hens suffering heat stress during hot weather. A total of 48,451 ISA Brown layers were housed in a farm located in Gyeongsangnam-do, Republic of Korea. Five thermo-hydrometer loggers were installed inside the house to collect data of dry-bulb temperature and relative humidity. The experiment continued for 81 days when the summer season begins from 19th June to 7th September, 2018. This study analyzed the correlations among layers' production index and daily average, highest, and lowest temperature; daily average, highest, and lowest relative humidity; and daily average, minimum, and maximum THI. The result indicated that feed consumption, hen-day egg production, egg weight, and FCR decreased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.01). On the other hand, water intake increased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.001). The relative humidity was not considered to have direct correlations to the layers' production index (p>0.05). However, it was noticeable that the mortality did not have significant relations with daily average and highest temperature; THI; or daily average, highest and lowest relative humidity while it was relevant to the daily lowest temperature and THI (p<0.05). In conclusion, to enhance the productivity of laying hens in a hot climate, it is recommended that daily average, highest, and lowest dry-bulb temperature and THI are maintained as low as possible. Especially, the daily lowest temperature is needed to lower to 20℃, which is the lowest critical temperature for layers.

Effect of Additional Early-Morning Heating Periods on the Growth and Yield of Cucumber and Heating Load (조조가온기간이 시설재배 오이의 생육과 수량 및 난방부하에 미치는 영향)

  • Kwon Joon Kook;Kang Nam Jun;Lee Jae Han;Kang Kyung Hee;Choi Young Hah
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.245-250
    • /
    • 2004
  • To investigate the effect of early-morning heating periods on growth and yield of cucumber and heating load in a greenhouse cultivation, three additional heating periods (0, 1 and 2 hours) were compared to rise temperature from $12^{\circ}C\;to\;16^{\circ}C$ in the early-morning. Leaf temperature just before opening the thermal screen was $3.3^{\circ}C\;and\;4.1^{\circ}C$ higher in the 1 and 2 hour heating compared to that in the control (0 hour heating), respectively. Photosynthetic rate, conductance to $H_2O$ and transpiration rate of cucumber leaves were the highest in the 2 hour heating, and the lowest in the control. However. the difference between the 1 hour and 2 hour heating was not significant. Inorganic element content in cucumber leaves was not significant among the treatments of duration. Initial growth after planting of cucumber was greater in the 1 and 2 hour heating than that in the control. Yield increased by $11\%\;and\;15\%$ in the 1 hour and 2 hour heating compared to that in the control. respectively. Fuel consumption for heating increased by $12\%\;and\;22\%$ in the 1 hour and 2 hour heating compared to that in the control, respectively. Considering in the yield and fuel consumption for heating. 1 or 2 hours of early morning heating could be effective in temperature management for cucumber in a greenhouse cultivation.

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.