• Title/Summary/Keyword: Thermal responses

Search Result 427, Processing Time 0.03 seconds

Subjective Responses to Thermal Stress for the Outdoor Performance of Smart Clothes

  • Kwon, JuYoun;Parsons, Ken
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.169-181
    • /
    • 2017
  • Objective: The aim of this study was to explore the influence of outdoor weather conditions on subjective responses during physical activity. Background: The largest difference between indoor and outdoor conditions is the existence of the sun. The heat load from the sun has an influence on the heat gain of the human body and the intense degree of solar radiation affected thermal comfort. Method: Thirty eight people were exposed to a range of climatic conditions in the UK. Weather in England does not have extremely hot and cold temperature, and the current study was conducted under warm (summer and autumn) and cool (spring and summer) climates. Measurements of the climate included air temperature, radiant temperature (including solar load), humidity and wind around the subjects. Subjective responses were taken and physiological measurements included internal body temperature, heart rate and sweat loss. Results: This study was conducted under four kinds of environmental conditions and the environmental measurement was performed in September, December, March, and June. The values for sensation, comfort, preference, and pleasantness about four conditions were from 'neutral' to 'warm', from 'not uncomfortable' to 'slightly comfortable', from 'slightly cooler' to 'slightly warmer', and from 'neither pleasant nor unpleasant' and 'slightly unpleasant', respectively. All subjective responses showed differences depending on air temperature and wind speed, and had correlations with air temperature and wind speed (p<0.05). However, subjective responses showed no differences depending on the radiant temperature. The combined effects of environmental parameters were showed on some subjective responses. The combined effects of air temperature and radiant temperature on thermal sensation and pleasantness were significant. The combined effects of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on some subjective responses. In the case of the relationships among subjective responses, thermal sensation had significant correlations with all subjective responses. The largest relationship was shown between preference and thermal sensation but acceptance showed the lowest relationship with the other subjective responses. Conclusion: The ranges of air temperature, radiant temperature, wind speed and solar radiation were $6.7^{\circ}C$ to $24.7^{\circ}C$, $17.9^{\circ}C$ to $56.6^{\circ}C$, $0.84ms^{-1}$ to $2.4ms^{-1}$, and $123Wm^{-2}$ to $876Wm^{-2}$ respectively. Each of air temperature and wind speed had significant relationships with subjective responses. The combined effects of environmental parameters on subjective responses were shown. Each radiant temperature and solar radiation did not show any relationships with subjective responses but the combinations of each radiant temperature and solar radiation with other environmental parameters had influences on subjective responses. The combinations of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on subjective responses although metabolic rate alone hardly made influences on them. There were also significant relationships among subjective responses, and pleasantness generally showed relatively high relationships with comfort, preference, acceptance and satisfaction. Application: Subjective responses might be utilized to predict thermal stress of human and the application products reflecting human subjective responses might apply to the different fields such as fashion technology, wearable devices, and environmental design considering human's response etc.

An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities (老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價)

  • Kwak, Ho;Ryoo, Woo-Dong;Hwang, Kwang-Il;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

Calcium Channel Blockers Suppress the Responses of Rat Dorsal Horn Cell to Nociceptive Input (쥐 척수후각세포의 유해자극 반응에 대한 칼슘이온통로 차단제의 억제작용)

  • Kang, Sok-Han;Kim, Kee-Soon;Shin, Hong-Kee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.625-637
    • /
    • 1997
  • Calcium ions are implicated in a variety of physiological functions, including enzyme activity, membrane excitability, neurotransmitter release, and synaptic transmission, etc. Calcium antagonists have been known to be effective for the treatment of exertional angina and essential hypertension. Selective and nonselective voltage-dependent calcium channel blockers also have inhibitory action on the acute and tonic pain behaviors resulting from thermal stimulation, subcutaneous formalin injection and nerve injury. This study was undertaken to investigate the effects of iontophoretically applied $Ca^{++}$ and its antagonists on the responses of WDR (wide dynamic range) cells to sensory inputs. The responses of WDR cells to graded electrical stimulation of the afferent nerve and also to thermal stimulation of the receptive field were recorded before and after iontophoretical application of $Ca^{++}$, EGTA, $Mn^{++}$, verapamil, ${\omega}-conotoxin$ GVIA, ${\omega}-conotoxin$ MVIIC and ${\omega}-agatoxin$ IVA. Also studied were the effects of a few calcium antagonists on the C-fiber responses of WDR cells sensitized by subcutaneous injection of mustard oil (10%). Calcium ions and calcium channel antagonists ($Mn^{++}$, verapamil, ${\omega}-conotoxin$ GVIA & ${\omega}-agatoxin$ IVA) current-dependently suppressed the C-fiber responses of WDR cells without any significant effects on the A-fiber responses. But ${\omega}-conotoxin$ MVIIC did not have any inhibitory actions on the responses of WDR cell to A-fiber, C-fiber and thermal stimulation. Iontophoretically applied EGTA augmented the WDR cell responses to C-fiber and thermal stimulations while spinal application of EGTA for about $20{\sim}30\;min$ strongly inhibited the C-fiber responses. The augmenting and the inhibitory actions of EGTA were blocked by calcium ions. The WDR cell responses to thermal stimulation of the receptive field were reduced by iontophoretical application of $Ca^{++}$, verapamil, ${\omega}-agatoxin$ IVA, and ${\omega}-conotoxin$ GVIA but not by ${\omega}-conotoxin$ MVIIC. The responses of WDR cells to C-fiber stimulation were augmented after subcutaneous injection of mustard oil (10%, 0.15 ml) into the receptive field and these sensitized C-fiber responses were strongly suppressed by iontophoretically applied $Ca^{++}$, verapamil, ${\omega}-conotoxin$ GVIA and ${\omega}-agatoxin$ IVA. These experimental findings suggest that in the rat spinal cord, L-, N-, and P-type, but not Q-type, voltage-sensitive calcium channels are implicated in the calcium antagonist-induced inhibition of the normal and the sensitized responses of WDR cells to C-fiber and thermal stimulation, and that the suppressive effect of calcium and augmenting action of EGTA on WDR cell responses are due to changes in excitability of the cell.

  • PDF

Transient thermo-piezo-elastic responses of a functionally graded piezoelectric plate under thermal shock

  • Xiong, Qi-lin;Tian, Xin
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2017
  • In this work, transient thermo-piezo-elastic responses of an infinite functionally graded piezoelectric (FGPE) plate whose upper surface suffers time-dependent thermal shock are investigated in the context of different thermo-piezo-elastic theories. The thermal and mechanical properties of functionally graded piezoelectric plate under consideration are expressed as power functions of plate thickness variable. The solution of problem is obtained by solving the corresponding finite element governing equations in time domain directly. Transient thermo-piezo-elastic responses of the FGPE plate, including temperature, stress, displacement, electric intensity and electric potential are presented graphically and analyzed carefully to show multi-field coupling behaviors between them. In addition, the effects of functionally graded parameters on transient thermo-piezo-elastic responses are also investigated to provide a theoretical basis for the application of the FGPE materials.

Evaluation of Thermal Comfort on Temperature Differences between Outdoor and Indoor Thermal Conditions in Summer (여름철 실내외 온도차에 따른 인체의 온열쾌적성 평가)

  • 금종수;김동규;최광환;이낙범;임재중;최호선;배동석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.890-896
    • /
    • 2002
  • Purpose of this study is to clarify the evaluation of thermal comfort based on temperature differences between outdoor and indoor thermal conditions in summer. The experiments were performed to evaluate temperature difference between indoor and outdoor thermal conditions (29, 31, $33^{\circ}$) by physiological and psychological responses of human. According to physiological responses, TSV (thermal sensation vote) and CSV (comfort sensation vote) and psychological responses, ECG (electrocardiogram), MST (mean skin temperature) of human, it was clear that the optimum temperature difference is about $5^{\circ})\;and\;7^{\circ}$).

A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space (불균등 복사공간의 쾌적온도범위 설정에 관한 연구)

  • Sohn, Jang-Yeul;Kong, Sung-Hoon;Yun, Yong-Jin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

Numerical Simulations of Subcritical Reactor Kinetics in Thermal Hydraulic Transient Phases

  • J. Yoo;Park, W. S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.149-154
    • /
    • 1998
  • A subcritical reactor driven by a linear proton accelerator has been considered as a nuclear waste incinerator at Korea Atomic Energy Research Institute(KAERI). Since the multiplication factor of a subcritical reactor is less than unity, to compensate exponentially decreasing fission neutrons from spallation reactions are essentially required for operating the reactor in its steady state. furthermore, the profile of accelerator beam currents is very important in controlling a subcritical reactor, because the reactor power varies in accordance of the profile of external neutrons. We have developed a code system to find numerical solutions of reactor kinetics equations, which are the simplest dynamic model for controlling reactors. In a due course of our previous numerical study of point kinetics equations for critical reactors, however, we learned that the same code system can be used in studying dynamic behavior of the subcritical reactor. Our major motivation of this paper is to investigate responses of subcritical reactors for small changes in thermal hydraulic parameters. Building a thermal hydraulic model for the subcritical reactor dynamics, we performed numerical simulations for dynamic responses of the reactor based on point kinetics equations with a source term. Linearizing a set of coupled differential equations for reactor responses, we focus our research interest on dynamic responses of the reactor to variations of the thermal hydraulic parameters in transient phases.

  • PDF

Effect of Rock Mass Properties on Coupled Thermo-Hydro-Mechanical Responses at Near-Field Rock Mass in a Heater Test - A Benchmark Sensitivity Study of the Kamaishi Mine Experiment in Japan

  • Hwajung Yoo;Jeonghwan Yoon;Ki-Bok Min
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.23-41
    • /
    • 2023
  • Coupled thermo-hydraulic-mechanical (THM) processes are essential for the long-term performance of deep geological disposal of high-level radioactive waste. In this study, a numerical sensitivity analysis was performed to analyze the effect of rock properties on THM responses after the execution of the heater test at the Kamaishi mine in Japan. The TOUGH-FLAC simulator was applied for the numerical simulation assuming a continuum model for coupled THM analysis. The rock properties included in the sensitivity study were the Young's modulus, permeability, thermal conductivity, and thermal expansion coefficients of crystalline rock, rock salt, and clay. The responses, i.e., temperature, water content, displacement, and stress, were measured at monitoring points in the buffer and near-field rock mass during the simulations. The thermal conductivity had an overarching impact on THM responses. The influence of Young's modulus was evident in the mechanical behavior, whereas that of permeability was noticed through the change in the temperature and water content. The difference in the THM responses of the three rock type models implies the importance of the appropriate characterization of rock mass properties with regard to the performance assessment of the deep geological disposal of high-level radioactive waste.

Physiological Responses of Cold Protective Clothing with Different clo Value (보온력 차이에 따른 방한복 상의의 인체착의 생리반응)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

Central Projections of Sensory Information Produced by Topical Application of Capsaicin to the Tongue in the Cat

  • Hong, Seung-Kil;Nahm, Sook-Hyun;Han, Hee-Chul;Suh, Young-Suk;Won, Ran;Lee, Bae-Hwan
    • The Korean Journal of Physiology
    • /
    • v.25 no.1
    • /
    • pp.87-99
    • /
    • 1991
  • In order to elucidate whether capsaicin applied topically acts as a pain-producing subastance or as a tastant, neuronal activities of the chorda tympani nerve(CN), lingual nerve(LN), solitary tract nucleus(STN), and trigeminal nucleus(TGN) were recorded while thermal and taste stimuli, and capsaicin were being applied topically, and algesics intra-arterially to the tongue of cats anesthetized with ${\alpha}-chloralsoe$. In addition, the STN neurons were examined after wheat germ agglutinin-horseradish peroxidase(WGA-HRP) was applied to the CN. The CN fibers responded to taste and thermal stimuli, algesics, and capsaicin. Responses to capsaicin were significantly correlated with those to taste and thermal stimuli. The LN fibers mainly responded to mechanical and thermal stimuli, algesics, and capsaicin. Responses to capsaicin were significantly correlated with those to algesics. The STN neurons responded to taste and thermal stiumli, algesics, and capsaicin. Responses to capsaicin were significantly correlated with those to taste and thermal stiumli in somewhat different fashion from those of the CN fibers. The TGN neurons mainly responded to mechanical stimuli, algesics, and capsaicin. Correlations between responses to capsaicin and any others were not significant. After WGA-HRP was applied to the CN, the STN neurons which receive input from the CN were identified largely in the medio-ventral portion to the solitary tract. These results suggest that capsaicin produce taste as well as pain sensation. Sensory information evoked by capsaicin can be conveyed to the STN, especially medio-ventral portion, via the CN as gustatory information on the one hand, and to the STN or TGN via the LN as noxious information on the other. In addiation, the noxious information may be conveyed to the STN via the CN.

  • PDF